Guidelines for measurement validation in clinical trial design.

M M Sanchez1, B S Binkowitz.   

Abstract

In the process of designing a clinical trial, the accuracy and precision of an endpoint is of critical importance in being able to determine valid results. In the creation and subsequent testing of the validity of an endpoint, it is desirable to show that on repeated measurements the endpoint can be measured precisely, and that it is reproducible with not only itself, but with any "gold standard" that can assess accuracy. Short of having this gold standard, we rely on showing that the endpoint is reliable. Agreement is the extent to which the measurement of the variable of interest yields the same results (consistency) on repeated trials. Thus the more consistent the results given by repeated measurements, the more reliable the measuring procedure. In this article, we examine the sensitivity to location and scale shift of different methods for assessing agreement. These tools include Pearson's correlation coefficient, the intraclass correlation coefficient, the concordance correlation coefficient, the Bradley-Blackwood procedure, and the within patient coefficient of variation. Our simulation studies showed that there are situations wherein the various methods for assessing agreement give conflicting results. On the basis of the results of the simulation studies, there are three important components to consider when deciding whether two sets of measurements are in agreement or not. The first component is the degree of linear relationship between the two sets; the second is the amount of bias as represented by the difference in the means; and the third is the difference between the two variances. The purpose of this article is to help interpret numerical results from the measures of agreement and to establish a criterion or range of values for each agreement measure that we consider to indicate agreement. We clarify what is meant by agreement by placing the measures in context based on scale and location shifts. Furthermore, we present guidelines for assessing agreement or endpoint validation when there are plans to design a clinical trial, and we give an actual example from a recent study.

Entities:  

Mesh:

Year:  1999        PMID: 10473029     DOI: 10.1081/BIP-100101185

Source DB:  PubMed          Journal:  J Biopharm Stat        ISSN: 1054-3406            Impact factor:   1.051


  8 in total

1.  To what degree is digital imaging reliable? Validation of femoral neck shaft angle measurement in the era of picture archiving and communication systems.

Authors:  J D Wilson; W Eardley; S Odak; A Jennings
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

2.  Development of an in vivo target-engagement biomarker for TRPA1 antagonists in humans.

Authors:  Linde Buntinx; Lin Chang; Aasim Amin; Bart Morlion; Jan de Hoon
Journal:  Br J Clin Pharmacol       Date:  2016-11-17       Impact factor: 4.335

3.  A multicenter pilot evaluation of the National Institutes of Health chronic graft-versus-host disease (cGVHD) therapeutic response measures: feasibility, interrater reliability, and minimum detectable change.

Authors:  Sandra A Mitchell; David Jacobsohn; Kimberly E Thormann Powers; Paul A Carpenter; Mary E D Flowers; Edward W Cowen; Mark Schubert; Maria L Turner; Stephanie J Lee; Paul Martin; Michael R Bishop; Kristin Baird; Javier Bolaños-Meade; Kevin Boyd; Jane M Fall-Dickson; Lynn H Gerber; Jean-Pierre Guadagnini; Matin Imanguli; Michael C Krumlauf; Leslie Lawley; Li Li; Bryce B Reeve; Janine Austin Clayton; Georgia B Vogelsang; Steven Z Pavletic
Journal:  Biol Blood Marrow Transplant       Date:  2011-04-12       Impact factor: 5.742

4.  Clinical Utility of 'Peekaboo Vision' Application for Measuring Grating Acuity in Children with Down Syndrome.

Authors:  Rebecca Sumalini; PremNandhini Satgunam; Ahalya Subramanian; Miriam Conway
Journal:  Br Ir Orthopt J       Date:  2022-05-04

5.  Reproducibility of the capsaicin-induced dermal blood flow response as assessed by laser Doppler perfusion imaging.

Authors:  B J Van der Schueren; J N de Hoon; F H Vanmolkot; A Van Hecken; M Depre; S A Kane; I De Lepeleire; S R Sinclair
Journal:  Br J Clin Pharmacol       Date:  2007-06-19       Impact factor: 4.335

6.  The effect of high-flow arteriovenous fistulas on systemic haemodynamics and brain oxygenation.

Authors:  Jan Malik; Anna Valerianova; Vladimir Tuka; Pavel Trachta; Vladimira Bednarova; Zdenka Hruskova; Marcela Slavikova; Mitchell H Rosner; Vladimir Tesar
Journal:  ESC Heart Fail       Date:  2021-03-23

7.  Comparison of Cellulite Severity Scales and Imaging Methods.

Authors:  V Leroy Young; Barry E DiBernardo
Journal:  Aesthet Surg J       Date:  2021-05-18       Impact factor: 4.283

8.  Low validity of the Sensewear Pro3 activity monitor compared to indirect calorimetry during simulated free living in patients with osteoarthritis of the hip.

Authors:  Andreas Hermann; Mathias Ried-Larsen; Andreas Kryger Jensen; René Holst; Lars Bo Andersen; Søren Overgaard; Anders Holsgaard-Larsen
Journal:  BMC Musculoskelet Disord       Date:  2014-02-19       Impact factor: 2.362

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.