| Literature DB >> 35601243 |
Rebecca Sumalini1, PremNandhini Satgunam1, Ahalya Subramanian2, Miriam Conway2.
Abstract
Peekaboo Vision is an iPad grating acuity app built with typically developing children in mind. Given the ease of using this app in the pediatric age group, this study determined its clinical utility in children with Down syndrome. Two groups of participants (children with Down syndrome and age-matched controls) were included. Presenting binocular grating acuity was measured using Peekaboo Vision and Teller acuity cards II in random order. Parents' feedback about their child's engagement and time taken to complete each test was documented. Thirty-seven children with Down syndrome (males = 23; mean age = 8.1 ± 4.2 years) and 28 controls (males = 15; mean age = 8.71 ± 3.84 years) participated. Time taken to complete the tests was comparable (p = 0.83) in children with Down syndrome. Controls were significantly faster with Peekaboo Vision (p = 0.01). Mean logMAR acuities obtained with Peekaboo Vision (0.16 ± 0.34) and Teller acuity cards II (0.63 ± 0.34) were significantly different (p < 0.001) in children with Down syndrome (mean difference in acuities: -0.44 ± 0.38 logMAR (95% LoA: -1.18 to 0.3). For controls, the mean logMAR acuity with Peekaboo Vision (-0.13 ± 0.12) and Teller acuity cards II (0.12 ± 0.09) was also found to be significantly different (p < 0.001) (mean difference in acuities: -0.24 ± 0.14 logMAR (95% LoA: -0.51 to 0.03) Peekaboo Vision test can be used on children with Down syndrome. Peekaboo Vision and Teller acuity cards II can be used independently but not interchangeably. The differences in the acuity values between the two tests could be a result of the differences in the thresholding paradigms, different testing mediums and the range of acuities covered. Copyright:Entities:
Keywords: Down syndrome; Grating acuity; Peekaboo Vision; Teller acuity cards II
Year: 2022 PMID: 35601243 PMCID: PMC9075052 DOI: 10.22599/bioj.264
Source DB: PubMed Journal: Br Ir Orthopt J ISSN: 1743-9868
Clinical and demographic characteristics of the participants.
|
| |||
|---|---|---|---|
| S NO. | DEMOGRAPHIC/CLINICAL PARAMETER | CHILDREN WITH DOWN SYNDROME (N = 37) | CONTROL GROUP (N = 28) |
|
| |||
| 1 |
| ||
|
| |||
| (Mean ± SD) | 8.1 ± 4.2 | 8.71 ± 3.84 | |
|
| |||
| Range | 1.3 to 17.0 | 2.3–15.0 | |
|
| |||
| 2 |
| ||
|
| |||
| Males | 23 (62%) | 15(54%) | |
|
| |||
| Females | 14 (38%) | 13 (46%) | |
|
| |||
| 3 |
| ||
|
| |||
| Peekaboo Vision | 1.8 ± 0.8 | 1.17 ± 0.38 | |
|
| |||
| Teller acuity cards II | 1.9 ± 0.8 | 1.44 ± 0.49 | |
|
| |||
| p-value | 0.83 | 0.01 | |
|
| |||