Literature DB >> 10468232

Pulse pressure method and the area method for the estimation of total arterial compliance in dogs: sensitivity to wave reflection intensity.

P Segers1, P Verdonck, Y Deryck, S Brimioulle, R Naeije, S Carlier, N Stergiopulos.   

Abstract

We estimated total arterial compliance (C) in eight anesthetized mongrel dogs with (i) the area method (AM), (ii) the pulse pressure method (PPM), and (iii) the stroke volume-to-pulse pressure ratio (SV/PP). Average compliance was C(AM)=1.1+/-0.73 ml mm Hg(-1) using AM; C(PPM)=0.60+/-0.31 ml mm Hg(-1) using PPM and C(SV/PP)=0.87+/-0.49 ml mm Hg(-1) using SV/PP. Mean aortic pressure was 64+/-23 mm Hg. The overall agreement between C(AM) and C(PPM) was relatively poor (C(AM)=0.15+/-1.61 C(PPM); r2=0.48), with a consistent overestimation of the area method with respect to the pulse pressure method. There was a significant correlation (r=-0.78) between the relative difference between PPM and AM, and the modulus of the first harmonic of the wave reflection coefficient [gamma] which was low in our dog population (0.37+/-0.18). SV/PP overestimated PPM, but both methods were highly correlated (C(SV/PP)=0.06+/-1.60C(PPM); r2=0.97). C(SV/PP) and C(AM) were similar only for [gamma]>0.4. The effect of isolated changes of [gamma] on PPM, AM, and SV/PP was studied using the linear wave separation technique. The area method appeared very sensitive to the wave reflection intensity. For low reflection coefficients, the diastolic wave profile was flattened and compliance was overestimated. PPM and SV/PP were relatively independent of [gamma] and remained even applicable for [gamma]=0. We believe that the pulse pressure method is the most consistent method for the estimation of total arterial compliance in hemodynamic conditions characterized by a low wave reflection intensity.

Entities:  

Mesh:

Year:  1999        PMID: 10468232     DOI: 10.1114/1.192

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  14 in total

1.  Use of the Frank-Starling mechanism during exercise is linked to exercise-induced changes in arterial load.

Authors:  Paul D Chantler; Vojtech Melenovsky; Steven P Schulman; Gary Gerstenblith; Lewis C Becker; Luigi Ferrucci; Jerome L Fleg; Edward G Lakatta; Samer S Najjar
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-10-14       Impact factor: 4.733

Review 2.  The arterial Windkessel.

Authors:  Nico Westerhof; Jan-Willem Lankhaar; Berend E Westerhof
Journal:  Med Biol Eng Comput       Date:  2008-06-10       Impact factor: 2.602

3.  Impact of systemic hypertension on the assessment of aortic stenosis.

Authors:  L Kadem; J G Dumesnil; R Rieu; L-G Durand; D Garcia; P Pibarot
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

4.  Beat-by-beat assessment of cardiac afterload using descending aortic velocity-pressure loop during general anesthesia: a pilot study.

Authors:  Fabrice Vallée; Arthur Le Gall; Jona Joachim; Olivier Passouant; Joaquim Matéo; Arnaud Mari; Sandrine Millasseau; Alexandre Mebazaa; Etienne Gayat
Journal:  J Clin Monit Comput       Date:  2017-01-20       Impact factor: 2.502

5.  Total arterial compliance estimated by a novel method and all-cause mortality in the elderly: the PROTEGER study.

Authors:  Theodore G Papaioannou; Athanase D Protogerou; Nikolaos Stergiopulos; Orestis Vardoulis; Christodoulos Stefanadis; Michel Safar; Jacques Blacher
Journal:  Age (Dordr)       Date:  2014-05-07

6.  Determination of Aortic Characteristic Impedance and Total Arterial Compliance From Regional Pulse Wave Velocities Using Machine Learning: An in-silico Study.

Authors:  Vasiliki Bikia; Georgios Rovas; Stamatia Pagoulatou; Nikolaos Stergiopulos
Journal:  Front Bioeng Biotechnol       Date:  2021-05-13

7.  Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients.

Authors:  Manuel Ignacio Monge García; Anselmo Gil Cano; Manuel Gracia Romero
Journal:  Crit Care       Date:  2011-01-12       Impact factor: 9.097

8.  The resistance-compliance product of the pulmonary circulation varies in health and pulmonary vascular disease.

Authors:  Charaka Hadinnapola; Qiuju Li; Li Su; Joanna Pepke-Zaba; Mark Toshner
Journal:  Physiol Rep       Date:  2015-04

9.  Effects of inhaled iloprost on right ventricular contractility, right ventriculo-vascular coupling and ventricular interdependence: a randomized placebo-controlled trial in an experimental model of acute pulmonary hypertension.

Authors:  Steffen Rex; Carlo Missant; Piet Claus; Wolfgang Buhre; Patrick F Wouters
Journal:  Crit Care       Date:  2008-09-10       Impact factor: 9.097

10.  Impact of arterial load on the agreement between pulse pressure analysis and esophageal Doppler.

Authors:  Manuel Ignacio Monge García; Manuel Gracia Romero; Anselmo Gil Cano; Andrew Rhodes; Robert Michael Grounds; Maurizio Cecconi
Journal:  Crit Care       Date:  2013-06-20       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.