Literature DB >> 10465564

Spatial distribution of QT dispersion measured by magnetocardiography under stress in coronary artery disease.

B Hailer1, P Van Leeuwen, S Lange, M Wehr.   

Abstract

This study investigated changes in spatial distribution of QT duration in patients with and without coronary artery disease (CAD) using magnetocardiography. Thirty-six-channel magnetocardiograms (MCGs) were registered at rest and under stress in 15 patients with chest pain, seven of whom had significant coronary stenosis. QT dispersion (QTd) was calculated for MCG and 12-lead electrocardiogram (ECG) under both conditions. For MCG, homogeneity of repolarization was measured using a smoothness index (SI). Also, at each registration site, the intraindividual difference between QT at rest and under stress was determined (deltaQT). QTd values as determined by standard 12-lead configurations were not significantly different between groups. MCG QTd values were significantly higher in the CAD group at rest only when all available channels were taken into consideration (P < .05); SI values differed significantly between groups under both conditions (rest, P < .005; stress, P < .01). Good separation between groups was possible using the range of deltaQT (P < .05) and SI (deltaQT) (P < .005). Consideration of the spatial distribution of QTd increases its sensitivity in the detection of CAD, suggesting that CAD involves complex changes in repolarization, not apparent in limited lead sets such as standard 12-lead configurations.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10465564

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

1.  A method for detecting myocardial abnormality by using a total current-vector calculated from ST-segment deviation of a magnetocardiogram signal.

Authors:  A Kandori; H Kanzaki; K Miyatake; S Hashimoto; S Itoh; N Tanaka; T Miyashita; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

2.  A method for detecting myocardial abnormality by using a current-ratio map calculated from an exercise-induced magnetocardiogram.

Authors:  A Kandori; H Kanzaki; K Miyatake; S Hashimoto; S Itoh; N Tanaka; T Miyashita; K Tsukada
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

3.  Effectiveness of magnetocardiography to identify patients in need of coronary artery revascularization: a cross-sectional study.

Authors:  Xiao Huang; Ning Hua; Fakuan Tang; Shulin Zhang
Journal:  Cardiovasc Diagn Ther       Date:  2020-08

4.  Spatial repolarization heterogeneity detected by magnetocardiography correlates with cardiac iron overload and adverse cardiac events in beta-thalassemia major.

Authors:  Chun-An Chen; Meng-Yao Lu; Shinn-Forng Peng; Kai-Hsin Lin; Hsiu-Hao Chang; Yung-Li Yang; Shiann-Tarng Jou; Dong-Tsamn Lin; Yen-Bin Liu; Herng-Er Horng; Hong-Chang Yang; Jou-Kou Wang; Mei-Hwan Wu; Chau-Chung Wu
Journal:  PLoS One       Date:  2014-01-27       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.