Literature DB >> 10464731

Increasing sampling density improves reproducibility of optical coherence tomography measurements.

R Gurses-Ozden1, H Ishikawa, S T Hoh, J M Liebmann, A Mistlberger, D S Greenfield, H L Dou, R Ritch.   

Abstract

PURPOSE: Published series of peripapillary retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) have sampled 100 evenly distributed points on a 360 degrees peripapillary circular scan. The goal of this study was to determine whether a four-fold increase in sampling density improves the reproducibility of OCT measurements.
METHODS: Complete ophthalmic examinations, achromatic automated perimetry, and OCT imaging were performed in all patients. The OCT scanning consisted of three superior and inferior quadrantic scans (100 sampling points/quadrant) and three circular scans (25 points/quadrant). The RNFL thickness measurements and coefficient of variation (CV) were calculated for the superior and inferior quadrants for each sampling density technique.
RESULTS: The study included 22 eyes of 22 patients (3 control subjects; 2 patients with ocular hypertension; and 17 patients with glaucoma). Quadrants with associated glaucomatous visual field loss on automated achromatic perimetry had thinner RNFLs than quadrants without functional defects for both the 25- and 100-points/quadrant scans. For quadrants associated with normal visual hemifields (n = 22), there was no difference between the 25- and 100-points/quadrant scans in mean RNFL thickness and CV. Among quadrants with visual field defects (n = 22), RNFL thickness measurements were thinner in the 25-points/quadrant scans than in the 100-points/quadrant scans. The CV for the 25-points/quadrant scans (25.9%) was significantly higher than that for the 100-points/quadrant scans (11.9%).
CONCLUSION: Increasing the sampling density of OCT scans provides less variable representation of RNFL thickness. The optimal sampling density to achieve maximal reliability of OCT scans remains to be determined.

Entities:  

Mesh:

Year:  1999        PMID: 10464731

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  13 in total

1.  The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer.

Authors:  A L Jones; N J Sheen; R V North; J E Morgan
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

Review 2.  Imaging in glaucoma.

Authors:  Daniel M Stein; Gadi Wollstein; Joel S Schuman
Journal:  Ophthalmol Clin North Am       Date:  2004-03

3.  Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.

Authors:  Ziad Khoueir; Firas Jassim; Linda Yi-Chieh Poon; Edem Tsikata; Geulah S Ben-David; Yingna Liu; Eric Shieh; Ramon Lee; Rong Guo; Georgia Papadogeorgou; Boy Braaf; Huseyin Simavli; Christian Que; Benjamin J Vakoc; Brett E Bouma; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2017-08-12       Impact factor: 5.258

Review 4.  Three dimensional optical coherence tomography imaging: advantages and advances.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Juan Xu; Jongsick Kim; Larry Kagemann; Lindsey S Folio; Joel S Schuman
Journal:  Prog Retin Eye Res       Date:  2010-06-11       Impact factor: 21.198

5.  Enhanced Diagnostic Capability for Glaucoma of 3-Dimensional Versus 2-Dimensional Neuroretinal Rim Parameters Using Spectral Domain Optical Coherence Tomography.

Authors:  Kenneth C Fan; Edem Tsikata; Ziad Khoueir; Huseyin Simavli; Rong Guo; Regina A de Luna; Sumir Pandit; Christian J Que; Johannes F de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2017-05       Impact factor: 2.503

6.  Diagnostic capability of peripapillary retinal thickness in glaucoma using 3D volume scans.

Authors:  Huseyin Simavli; Christian John Que; Mustafa Akduman; Jennifer L Rizzo; Edem Tsikata; Johannes F de Boer; Teresa C Chen
Journal:  Am J Ophthalmol       Date:  2014-12-09       Impact factor: 5.258

7.  Scan tracking coordinates for improved centering of Stratus OCT scan pattern.

Authors:  Gianmarco Vizzeri; Christopher Bowd; Felipe A Medeiros; Robert N Weinreb; Linda M Zangwill
Journal:  J Glaucoma       Date:  2009-01       Impact factor: 2.503

8.  Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients.

Authors:  Alfonso Antón; Marta Castany; Marta Pazos-Lopez; Ruben Cuadrado; Ana Flores; Miguel Castilla
Journal:  Clin Ophthalmol       Date:  2009-06-02

9.  The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography.

Authors:  Dong Ju Youm; Hyunjoong Kim; Seong Hee Shim; Hyo Ju Jang; Joon Mo Kim; Ki Ho Park; Chul Young Choi; Jung Gon Cho
Journal:  Korean J Ophthalmol       Date:  2012-03-22

10.  Peripapillary retinal thickness maps in the evaluation of glaucoma patients: a novel concept.

Authors:  Kayoung Yi; Mircea Mujat; Wei Sun; B Hyle Park; Johannes F de Boer; Teresa C Chen
Journal:  ISRN Ophthalmol       Date:  2011-09-07
View more