Literature DB >> 10455382

Influence of the digital image display monitor on observer performance.

R A Cederberg1, N L Frederiksen, B W Benson, J D Shulman.   

Abstract

OBJECTIVE: To assess the influence of the display monitor on observer performance.
MATERIAL AND METHODS: Artificial enamel lesions were created in 40 extracted teeth at random using 1/4 and 1/2 round burs. Teeth were mounted in dental stone blocks to simulate a hemidentition. Approximate exposures were recorded at 70 kVp using a Digota (Soredex, Orion Corp, Helsinki, Finland) digital imaging system, calibrated to achieve optimum density. Six dentists rated each image on a five-point scale for the presence or absence of a lesion. Radiographic images were viewed on the following monitors: (1) AlphaScan 711 (Sampo Corp.); (2) Multiscan 17 Se II (Sony Electronics Inc.); (3) DS 2000 (Clinton Electronics Corp.) and (4) Latitude CP Laptop (Dell Computer Corp.). Raters were allowed to magnify and to adjust density and contrast of each image at will. Receiver Operating Characteristic (ROC) analysis was performed and curves were plotted for each image. Data was subjected to repeated measures analysis of variance and ordinal logistic regression to test for significance between variables and to determine odds ratios.
RESULTS: Mean ROC curve areas ranged from 0.8728 for the Sampo monitor to 0.8395 for the Sony. Repeated measures analysis of variance showed significant differences between observers (P < 0.0001), lesion size (P < 0.0001), examiner/monitor interaction (P < 0.033) and examiner/block interaction (P < 0.013). However, no significant difference was found between monitors.
CONCLUSION: This study suggests that observer performance is independent of the visual characteristics of the display monitor.

Entities:  

Mesh:

Year:  1999        PMID: 10455382     DOI: 10.1038/sj/dmfr/4600441

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  10 in total

1.  Effect of ambient light level at the monitor surface on digital radiographic evaluation of approximal carious lesions: an in vitro study.

Authors:  K Hellén-Halme; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

2.  Effect of display type, DICOM calibration and room illuminance in bitewing radiographs.

Authors:  Soili Kallio-Pulkkinen; Sisko Huumonen; Marianne Haapea; Esa Liukkonen; Annina Sipola; Osmo Tervonen; Miika T Nieminen
Journal:  Dentomaxillofac Radiol       Date:  2015-08-03       Impact factor: 2.419

3.  LCD and CRT display of storage phosphor plate and limited cone beam computed tomography images for the evaluation of root canal fillings.

Authors:  B Güniz Baksi; Elif Soğur; Hans-Göran Gröndahl
Journal:  Clin Oral Investig       Date:  2008-07-30       Impact factor: 3.573

4.  Carious lesions: diagnostic accuracy using pre-calibrated monitor in various ambient light levels: an in vitro study.

Authors:  K Hellén-Halme; A Lith
Journal:  Dentomaxillofac Radiol       Date:  2013-06-17       Impact factor: 2.419

5.  Diagnostic accuracy of different display types in detection of recurrent caries under restorations by using CBCT.

Authors:  İsmail H Baltacıoĝlu; Hakan Eren; Yasemin Yavuz; Kıvanç Kamburoğlu
Journal:  Dentomaxillofac Radiol       Date:  2016-07-04       Impact factor: 2.419

6.  Applicability of Cameriere's and Drusini's age estimation methods to a sample of Turkish adults.

Authors:  Boyacioglu Dogru Hatice; Avcu Nihal; Akkaya Nursel; Yilanci Humeyra Ozge; Dincer Goksuluk
Journal:  Dentomaxillofac Radiol       Date:  2017-07-14       Impact factor: 2.419

7.  The Effects on Absorbed Dose Distribution in Intraoral X-ray Imaging When Using Tube Voltages of 60 and 70 kV for Bitewing Imaging.

Authors:  Kristina Hellén-Halme; Mats Nilsson
Journal:  J Oral Maxillofac Res       Date:  2013-10-01

8.  Diagnostic accuracy of digitized conventional radiographs by camera and scanner in detection of proximal caries.

Authors:  Solmaz Valizadeh; Mohammad Amin Tavakoli; Tara Zarabian; Farzad Esmaeili
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2009-12-15

9.  Image quality evaluation of eight complementary metal-oxide semiconductor intraoral digital X-ray sensors.

Authors:  Sorin Teich; Wisam Al-Rawi; Masahiro Heima; Fady F Faddoul; Gil Goldzweig; Zvi Gutmacher; Dror Aizenbud
Journal:  Int Dent J       Date:  2016-04-22       Impact factor: 2.607

10.  In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars.

Authors:  Abbasali Khademi; Masoud Saatchi; Mahnaz Sheikhi; Mohammad Mehdi Soltani; Samane Moradi
Journal:  Scanning       Date:  2022-09-19       Impact factor: 1.750

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.