Cardiac output and central blood volume during hemodialysis: methodology.

N M Krivitski1, T A Depner.   

Abstract

Cardiovascular disease is the leading cause of mortality in patients whose lives depend on hemodialysis. We developed a method for measuring cardiac output (CO) and central blood volume (CBV) in hemodialyzed patients that may help to elucidate the mechanisms and consequences of cardiac disease in this population. This report describes the technique, focusing on the main sources of error and how they can be prevented. Three principal sources of error were identified: (1) access recirculation (existing or induced during injection); (2) the second pass of the indicator through the cardiopulmonary system, exacerbated by prolonging the duration of intravenous injection; and (3) the transit time of the indicator through the dialysis blood lines. After the algorithms were adjusted to prevent the above errors, the reproducibility of CO and CBV, expressed as the absolute percent deviation from the average of duplicates (3,488 values duplicated within 5 minutes), was 4.3 +/- 3.8% for CO and 4.1 +/- 3.8% for CBV. To determine the clinical value of routine CO and CBV measurements, morbid events (nausea, vomiting, and/or muscle cramps) were prospectively recorded in 73 randomly selected hemodialysis patients. CO and CBV were measured near the beginning and near the end of 98 dialysis sessions during which 28 morbid events were identified. In 10 of these sessions, where morbid events took place within 30 minutes of the measurements, CBV appeared to be a more sensitive indicator of morbid events than CO. We conclude that CO and CBV can be routinely and reliably measured during hemodialysis if precautions are taken to avoid specifically identified sources of error. Preliminary studies suggest that these measurements may have significant prognostic value.

Entities:  

Mesh:

Year:  1999        PMID: 10452705     DOI: 10.1016/s1073-4449(99)70018-x

Source DB:  PubMed          Journal:  Adv Ren Replace Ther        ISSN: 1073-4449


  7 in total

1.  Comparison of cardiac output and blood volumes in intrathoracic compartments measured by ultrasound dilution and transpulmonary thermodilution methods.

Authors:  Gennady Galstyan; Mychaylo Bychinin; Mikael Alexanyan; Vladimir Gorodetsky
Journal:  Intensive Care Med       Date:  2010-08-06       Impact factor: 17.440

2.  Hemodynamic effects of acute and chronic administration of vapreotide in rats with cirrhosis.

Authors:  Nary Veal; Frédéric Moal; Frédéric Oberti; Eric Vuillemin; Paul Calés
Journal:  Dig Dis Sci       Date:  2003-01       Impact factor: 3.199

3.  Impact of extracorporeal blood flow rate on blood pressure, pulse rate and cardiac output during haemodialysis.

Authors:  Philip Andreas Schytz; Maria Lerche Mace; Anne Merete Boas Soja; Brian Nilsson; Nikolaos Karamperis; Bent Kristensen; Søren Daustrand Ladefoged; Henrik Post Hansen
Journal:  Nephrol Dial Transplant       Date:  2015-09-01       Impact factor: 5.992

4.  Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients.

Authors:  Nikolai M Krivitski; Victor V Kislukhin; Naveen V Thuramalla
Journal:  Pediatr Crit Care Med       Date:  2008-07       Impact factor: 3.624

5.  Short and Long-Term Effects of the Angiotensin II Receptor Blocker Irbesartan on Intradialytic Central Hemodynamics: A Randomized Double-Blind Placebo-Controlled One-Year Intervention Trial (the SAFIR Study).

Authors:  Christian Daugaard Peters; Krista Dybtved Kjaergaard; Jens Dam Jensen; Kent Lodberg Christensen; Charlotte Strandhave; Ida Noerager Tietze; Marija Kristina Novosel; Bo Martin Bibby; Bente Jespersen
Journal:  PLoS One       Date:  2015-06-01       Impact factor: 3.240

6.  Systemic haemodynamics in haemodialysis: intradialytic changes and prognostic significance.

Authors:  Stefanie Haag; Björn Friedrich; Andreas Peter; Hans-Ulrich Häring; Nils Heyne; Ferruh Artunc
Journal:  Nephrol Dial Transplant       Date:  2018-08-01       Impact factor: 5.992

7.  The impact of haemodialysis arteriovenous fistula on haemodynamic parameters of the cardiovascular system.

Authors:  Carlo Basile; Luigi Vernaglione; Francesco Casucci; Pasquale Libutti; Piero Lisi; Luigi Rossi; Valentina Vigo; Carlo Lomonte
Journal:  Clin Kidney J       Date:  2016-07-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.