Literature DB >> 10446484

A multi-zone model evaluation of the efficacy of upper-room air ultraviolet germicidal irradiation.

M Nicas1, S L Miller.   

Abstract

Engineering controls can be used to reduce the spread of airborne infectious disease, particularly tuberculosis (TB), in high-risk settings. This article evaluates published data on the efficacy of upper-room air ultraviolet germicidal irradiation (UVGI). A three-zone representation of a TB patient room equipped with a germicidal UV lamp is developed. The lamp irradiates the upper-room zone and inactivates airborne mycobacteria; the unirradiated lower-room zone also contains a near-field zone surrounding the TB patient. Infectious particles are generated in the near-field zone and transported throughout the room by air flow between zones. Each zone is independently well-mixed; the whole room, however, is not well-mixed. The three-zone model is applied to a previously published study of UVGI against airborne mycobacteria in a test room. Based on the estimated slopes of the semi-log concentration decay curves for viable mycobacteria, and on the assumption that the test room was essentially well-mixed, the published study reported that UVGI provided 10 to 25 equivalent air changes per hour. However, when the same decay curve slopes are interpreted in the context of the three-zone model, UVGI is seen to be far less effective in reducing exposure intensity near the TB patient. Near-field exposure intensity is relevant because health care workers are usually in close proximity to the TB patients they attend. In general, the interpretation of concentration decay data depends on the specific model of room air mixing that is assumed appropriate. It is recommended that tests of the efficacy of UVGI and other control devices against airborne microorganisms be based on steady-state concentration measurements rather than concentration decay measurements, because the former measurements do not require inferences based on a particular model.

Entities:  

Mesh:

Year:  1999        PMID: 10446484     DOI: 10.1080/104732299302909

Source DB:  PubMed          Journal:  Appl Occup Environ Hyg        ISSN: 1047-322X


  10 in total

1.  Treatment of fungal bioaerosols by a high-temperature, short-time process in a continuous-flow system.

Authors:  Jae Hee Jung; Jung Eun Lee; Chang Ho Lee; Sang Soo Kim; Byung Uk Lee
Journal:  Appl Environ Microbiol       Date:  2009-02-06       Impact factor: 4.792

2.  Minimizing the exposure of airborne pathogens by upper-room ultraviolet germicidal irradiation: an experimental and numerical study.

Authors:  Y Yang; W Y Chan; C L Wu; R Y C Kong; A C K Lai
Journal:  J R Soc Interface       Date:  2012-07-18       Impact factor: 4.118

3.  The antimicrobial efficacy of shielded ultraviolet germicidal irradiation in CT rooms with intense human circulation.

Authors:  Gülşah Yıldırım; Haluk Kılıç; Hakkı Muammer Karakaş
Journal:  Diagn Interv Radiol       Date:  2021-03       Impact factor: 2.630

4.  The history of ultraviolet germicidal irradiation for air disinfection.

Authors:  Nicholas G Reed
Journal:  Public Health Rep       Date:  2010 Jan-Feb       Impact factor: 2.792

5.  Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission.

Authors:  A Roderick Escombe; David A J Moore; Robert H Gilman; Marcos Navincopa; Eduardo Ticona; Bailey Mitchell; Catherine Noakes; Carlos Martínez; Patricia Sheen; Rocio Ramirez; Willi Quino; Armando Gonzalez; Jon S Friedland; Carlton A Evans
Journal:  PLoS Med       Date:  2009-03-17       Impact factor: 11.069

6.  Bayesian modeling of exposure and airflow using two-zone models.

Authors:  Yufen Zhang; Sudipto Banerjee; Rui Yang; Claudiu Lungu; Gurumurthy Ramachandran
Journal:  Ann Occup Hyg       Date:  2009-04-29

7.  Ultraviolet germicidal irradiation and its effects on elemental distributions in mouse embryonic fibroblast cells in x-ray fluorescence microanalysis.

Authors:  Qiaoling Jin; Stefan Vogt; Barry Lai; Si Chen; Lydia Finney; Sophie-Charlotte Gleber; Jesse Ward; Junjing Deng; Rachel Mak; Nena Moonier; Chris Jacobsen
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

8.  A systematic approach to estimating the effectiveness of multi-scale IAQ strategies for reducing the risk of airborne infection of SARS-CoV-2.

Authors:  Jialei Shen; Meng Kong; Bing Dong; Michael J Birnkrant; Jianshun Zhang
Journal:  Build Environ       Date:  2021-04-30       Impact factor: 6.456

9.  Inactivation of poxviruses by upper-room UVC light in a simulated hospital room environment.

Authors:  James J McDevitt; Donald K Milton; Stephen N Rudnick; Melvin W First
Journal:  PLoS One       Date:  2008-09-10       Impact factor: 3.240

10.  Application of mathematical models in combination with Monte Carlo simulation for prediction of isoflurane concentration in an operation room theater.

Authors:  Mohammad Javad Zare Sakhvidi; Abolfazl Barkhordari; Maryam Salehi; Shekoofeh Behdad; Hossein Fallahzadeh
Journal:  Ind Health       Date:  2013-08-02       Impact factor: 2.179

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.