Literature DB >> 10445712

Posterior chamber collamer phakic intraocular lens for myopia and hyperopia.

P M Pesando1, M P Ghiringhello, P Tagliavacche.   

Abstract

PURPOSE: To assess the feasibility of correcting refractive errors using a foldable posterior chamber phakic intraocular lens.
METHODS: Thirty-four foldable posterior chamber phakic intraocular lenses (STAAR Collamer intraocular lens) were consecutively implanted by the same surgeon (PMP) in 19 myopic eyes and 15 hyperopic eyes. In myopic eyes, mean preoperative spherical equivalent refraction was -16.65 +/-3.37 D (range, -8.12 to -21.25 D). In hyperopic eyes, mean preoperative spherical equivalent refraction was +7.77+/-2.08 D (range, +4.75 to +11.75 D). Mean follow-up was 12 months (range, 6 to 18 mo). Two hyperopic eyes were not included in the data analysis because of removal of the intraocular lens due to pupillary block.
RESULTS: Myopic eyes (n=19)-Mean spherical equivalent postoperative refraction was -1.51+/-1.37 D (range, -5.50 to+0.38 D). Postoperative refraction was within +/-0.50 D in 4 eyes (21.05%) and within +/-1.00 D in 8 eyes (42.10%). Uncorrected visual acuity was 20/40 or better in 12 eyes (63.15%) and 20/25 or better in 3 eyes (15.78%). No eye had an uncorrected visual acuity of 20/20 or better. Spectacle-corrected visual acuity was 20/40 or better in all eyes, 20/25 or better in 12 eyes (63.15%), and 20/20 or better in 1 eye (5.26%). Spectacle-corrected visual acuity was unchanged in 10 eyes (52.63%) and improved in 9 eyes (47.36%). A retinal detachment developed in 1 eye (5.26%). Hyperopic eyes (n=15)-Mean spherical equivalent postoperative refraction was +0.02+/-0.64 D (range, -1.00 to +1.50 D). Postoperative refraction was within +/-0.50 D in 9 eyes (69.25%) and +/-1.00 D in 12 eyes (92.30%). Uncorrected visual acuity was 20/40 or better in 6 eyes (46.15%) and 20/25 or better in 3 eyes (20.25%). No eye had an uncorrected visual acuity of 20/20 or better. Spectacle-corrected visual acuity was 20/40 or better in 7 eyes (53.84%), 20/25 or better in 6 eyes (46.15%), and 20/20 or better in 2 eyes (15.38%). Spectacle-corrected visual acuity was unchanged in 10 eyes (76.92%), significantly improved in 2 eyes (15.38%), and worse in 1 eye (7.69%). Two of 15 eyes (13.33%) developed a severe pupillary block necessitating removal of the implants. One eye (7.69%) developed an anterior subcapsular cataract.
CONCLUSIONS: Refractive predictability appears better for hyeropia than for myopia using the STAAR Collamer foldable posterior chamber phakic intraocular lens. In hyperopic eyes, development of pupillary block may occur.

Entities:  

Mesh:

Year:  1999        PMID: 10445712     DOI: 10.3928/1081-597X-19990701-05

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  14 in total

Review 1.  [Phakic intraocular lenses. Current status and limitations].

Authors:  H B Dick; M Tehrani
Journal:  Ophthalmologe       Date:  2004-03       Impact factor: 1.059

Review 2.  [Intraocular lenses for the correction of refraction errors. Part II. Phakic posterior chamber lenses and refractive lens exchange with posterior chamber lens implantation].

Authors:  T Kohnen; T Kasper; E Terzi
Journal:  Ophthalmologe       Date:  2005-11       Impact factor: 1.059

Review 3.  [Intraocular lenses for the correction of refraction errors. Part 1: phakic anterior chamber lenses].

Authors:  T Kohnen; M Baumeister; M Cichocki
Journal:  Ophthalmologe       Date:  2005-10       Impact factor: 1.059

4.  Posterior chamber phakic intraocular lens implantation for high myopia.

Authors:  Yan Ju; Xiao-Wei Gao; Bing Ren
Journal:  Int J Ophthalmol       Date:  2013-12-18       Impact factor: 1.779

5.  Phacomorphic glaucoma in a high myope with phakic intraocular lens.

Authors:  Talvir Sidhu; Arjun Desai; Meghal Gagrani; Tanuj Dada
Journal:  BMJ Case Rep       Date:  2019-02-25

6.  Visual improvement in high myopic amblyopic adult eyes following phakic anterior chamber intraocular lens implantation.

Authors:  Sang Won Kwon; Hyun Seung Moon; Kyung Hwan Shyn
Journal:  Korean J Ophthalmol       Date:  2006-06

7.  Correlations between magnitude of refractive error and other optical components in Korean myopes.

Authors:  Sangkyu Lee; Boyun Kim; Tae-Hoon Oh; Hyun Seung Kim
Journal:  Korean J Ophthalmol       Date:  2012-09-24

8.  Comparison of clear lens extraction and collamer lens implantation in high myopia.

Authors:  Ahmed M Emarah; Mostafa A El-Helw; Hazem M Yassin
Journal:  Clin Ophthalmol       Date:  2010-05-14

9.  Outcome of posterior chamber phakic intraocular lens procedure to correct myopia.

Authors:  Nasser Al Sabaani; Abdullah Al Assiri; Abdullah Al Torbak; Saeed Al Motawa
Journal:  Saudi J Ophthalmol       Date:  2013-07-01

10.  Biometric and ICL-related risk factors associated to sub-optimal vaults in eyes implanted with implantable collamer lenses.

Authors:  Santiago Cerpa Manito; Angel Sánchez Trancón; Oscar Torrado Sierra; António Manuel Baptista; Pedro Miguel Serra
Journal:  Eye Vis (Lond)       Date:  2021-07-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.