Literature DB >> 10426510

Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

G Messaris1, Z Kolitsi, C Badea, N Pallikarakis.   

Abstract

Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation of localisation accuracy and efficiency by correlation of tomographic and projectional images. The method introduces an element of direct verification and interactive optimisation of the process. Tomographic images are used for the identification of a point of interest. Its position is computed within the treatment co-ordinate system and verification of this position is achieved by obtaining the beam's eye view of the identified point on two projection radiographs. The key element of the approach is that all images used should be part of one single image data set. The implementation of this localisation method, as part of the functionality of a Digital Tomosynthesis prototype, has provided an integrated facility for localisation, of optimised accuracy and precision, while easy and efficient to use. The considerations are general and apply in principle to any imaging system that can augment tomographic images with projections.

Entities:  

Mesh:

Year:  1999        PMID: 10426510     DOI: 10.1016/s1350-4533(99)00015-6

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Prostate implant reconstruction from C-arm images with motion-compensated tomosynthesis.

Authors:  Ehsan Dehghan; Mehdi Moradi; Xu Wen; Danny French; Julio Lobo; W James Morris; Septimiu E Salcudean; Gabor Fichtinger
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Construction of realistic branched, three-dimensional arteries suitable for computational modelling of flow.

Authors:  S Corney; P R Johnston; D Kilpatrick
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

3.  Evaluation of respiration-correlated digital tomosynthesis in lung.

Authors:  Joseph Santoro; Sergey Kriminski; D Michael Lovelock; Kenneth Rosenzweig; Hassan Mostafavi; Howard I Amols; Gig S Mageras
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

4.  Prostate brachytherapy seed reconstruction with Gaussian blurring and optimal coverage cost.

Authors:  Junghoon Lee; Xiaofeng Liu; Ameet K Jain; Danny Y Song; Everette C Burdette; Jerry L Prince; Gabor Fichtinger
Journal:  IEEE Trans Med Imaging       Date:  2009-07-14       Impact factor: 10.048