Literature DB >> 10424550

Magnetic resonance imaging of bioabsorbale polylactic acid interference screws during the first 2 years after anterior cruciate ligament reconstruction.

W H Warden1, R Friedman, L M Teresi, D W Jackson.   

Abstract

Bioabsorbable screws composed of poly(L-lactic acid) (PLA) were used for graft fixation and studied prospectively with serial magnetic resonance imaging (MRI) scans at 8, 16, and 24 months after autogenous patellar tendon anterior cruciate ligament (ACL) reconstruction in 10 patients. Conventional spin echo, proton density, and T2-weighted double echo sequences were obtained, as well as T2-weighted fat-saturated fast spin echo sequences. All but one of the screws (19 of 20) were evident in all serial scans. These showed minimal decrease in size over time. The one screw that had completely disappeared 8 months after reconstruction had cracked during insertion. None of the reconstructed ACL grafts showed clinical instability, persistent effusions, or detectable adverse reactions to the screws. Two patients developed abnormal signal in the tibial tunnel: one developed fluid anterior to the graft, and the other developed increased signal within the graft. The abnormal signal resolved with time in both patients. Other than the preceding changes, no abnormalities were detected on conventional sequences. Fat-saturated fast spin echo sequences showed a variable amount of increased signal around the tunnels, suggesting edema or fibrovascular marrow changes. The changes noted near the tunnels on the fat-suppressed scans most probably represent a general reaction to surgical insult rather than a reaction to the bioabsorbable screws, as similar changes were noted at the patellar harvest site.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10424550     DOI: 10.1053/ar.1999.v15.015047

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  16 in total

1.  Analysis of initial fixation strength of press-fit fixation technique in anterior cruciate ligament reconstruction. A comparative study with titanium and bioabsorbable interference screw using porcine lower limb.

Authors:  Myung Chul Lee; Hyunchul Jo; Tae-Soo Bae; Jin Dae Jang; Sang Cheol Seong
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-03-06       Impact factor: 4.342

Review 2.  MR imaging evaluation of the postoperative knee: ligaments, menisci, and articular cartilage.

Authors:  Lawrence M White; Josef Kramer; Michael P Recht
Journal:  Skeletal Radiol       Date:  2005-06-21       Impact factor: 2.199

3.  Poly-L-lactic acid - hydroxyapatite (PLLA-HA) bioabsorbable interference screws for tibial graft fixation in anterior cruciate ligament (ACL) reconstruction surgery: MR evaluation of osteointegration and degradation features.

Authors:  L Macarini; P Milillo; A Mocci; R Vinci; G C Ettorre
Journal:  Radiol Med       Date:  2008-10-25       Impact factor: 3.469

Review 4.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

5.  Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model.

Authors:  Jean Y Lazennec; Abdallah Madi; Marc A Rousseau; Bernard Roger; Gérard Saillant
Journal:  Eur Spine J       Date:  2006-05-31       Impact factor: 3.134

6.  Magnetic resonance imaging appearance of anterior cruciate ligament reconstruction using Calaxo screws.

Authors:  Troy F Storey; William J Montgomery; Charles H Bush; Michael Moser
Journal:  Skeletal Radiol       Date:  2010-08-25       Impact factor: 2.199

7.  Failure strength of bioabsorbable interference screws: effects of in vivo degradation for 12 weeks.

Authors:  Onder Kilicoglu; Mehmet Demirhan; Senol Akman; Ata Can Atalar; Serhat Ozsoy; Umit Ince
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-05-08       Impact factor: 4.342

8.  Tibial tunnel widening after bioresorbable poly-lactide calcium carbonate interference screw usage in ACL reconstruction.

Authors:  Casper Foldager; Bent W Jakobsen; Bent Lund; Svend Erik Christiansen; Lotte Kashi; Lone R Mikkelsen; Martin Lind
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-16       Impact factor: 4.342

9.  A prospective randomized study of ACL-reconstructions using bone-patellar tendon-bone grafts fixed with bioabsorbable or metal interference screws.

Authors:  Jon Olav Drogset; Lene Granrud Straume; Ingrid Bjørkmo; Gunnar Myhr
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

10.  Magnetic resonance imaging analysis of the bioabsorbable Milagro interference screw for graft fixation in anterior cruciate ligament reconstruction.

Authors:  K-H Frosch; T Sawallich; G Schütze; A Losch; T Walde; P Balcarek; F Konietschke; K M Stürmer
Journal:  Strategies Trauma Limb Reconstr       Date:  2009-08-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.