Literature DB >> 10410166

Influence of film and monitor display luminance on observer performance and visual search.

E Krupinski1, H Roehrig, T Furukawa.   

Abstract

RATIONALE AND
OBJECTIVES: The purpose of this study was to measure the influence of display luminance on detection performance and visual search behavior. The results of the study should be helpful in establishing minimally acceptable display conditions for viewing radiographs on cathode-ray tube (CRT) monitors.
MATERIALS AND METHODS: Two groups of six radiologists each viewed 50 pairs of mammograms. One group viewed film images on a standard mammographic view box; the other viewed images on a high-resolution CRT monitor. Two luminance levels were studied for each display type. Observers reported on the presence or absence of masses or microcalcification clusters and on their confidence in that decision. Confidence data were analyzed by using alternative free-response receiver operating characteristic (AFROC) techniques. Eye position also was recorded as observers viewed the images.
RESULTS: For both the film and monitor studies, detection performance (AFROC area under the curve) was not affected significantly by display luminance, but search behavior was. Total viewing and decision dwell times were shorter with the higher-luminance displays, especially for true-negative decisions. Significantly more fixation clusters were generated during the search of lesion-free than of lesion-containing images with the lower-luminance displays.
CONCLUSION: Display luminance affects visual search performance with both film and monitor displays without affecting detection performance significantly. Higher-luminance displays yield more efficient search performance. The true-negative dwell times and number of clusters are suggestive that lower-luminance levels prolong the search and recognition of normal, lesion-free areas compared with lesion-containing areas.

Entities:  

Mesh:

Year:  1999        PMID: 10410166     DOI: 10.1016/s1076-6332(99)80191-3

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  9 in total

1.  Soft copy display requirements for digital mammography.

Authors:  Bradley M Hemminger
Journal:  J Digit Imaging       Date:  2003-12-15       Impact factor: 4.056

2.  An Evaluation of Performance Characteristics of Primary Display Devices.

Authors:  Ernest U Ekpo; Mark F McEntee
Journal:  J Digit Imaging       Date:  2016-04       Impact factor: 4.056

3.  Psychophysical analysis of monitor display functions affecting observer diagnostic performance of CT image on liquid crystal display monitors.

Authors:  M Yamaguchi; H Fujita; Y Asai; M Uemura; Y Ookura; M Matsumoto; T Johkoh
Journal:  Eur Radiol       Date:  2005-08-16       Impact factor: 5.315

4.  Comparison of color LCD and medical-grade monochrome LCD displays in diagnostic radiology.

Authors:  Håkan Geijer; Mats Geijer; Lillemor Forsberg; Susanne Kheddache; Patrik Sund
Journal:  J Digit Imaging       Date:  2007-06       Impact factor: 4.056

5.  Increasing display luminance as a means to enhance interpretation accuracy and efficiency when reducing full-field digital mammography dose.

Authors:  Elizabeth A Krupinski
Journal:  J Med Imaging (Bellingham)       Date:  2018-07-27

6.  Breast screen new South wales generally demonstrates good radiologic viewing conditions.

Authors:  BaoLin Pauline Soh; Warwick Lee; Jennifer L Diffey; Mark F McEntee; Peter L Kench; Warren M Reed; Patrick C Brennan
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

Review 7.  Review of prospects and challenges of eye tracking in volumetric imaging.

Authors:  Antje C Venjakob; Claudia R Mello-Thoms
Journal:  J Med Imaging (Bellingham)       Date:  2015-09-29

8.  Luminance affects age-related deficits in object detection: implications for computerized psychological assessments.

Authors:  Daniel R Seichepine; Sandy Neargarder; Meaghan E McCallum; Kristin Tabor; Tatiana M Riedel; Grover C Gilmore; Alice Cronin-Golomb
Journal:  Psychol Aging       Date:  2011-11-07

Review 9.  Human Factors and Human-Computer Considerations in Teleradiology and Telepathology.

Authors:  Elizabeth A Krupinski
Journal:  Healthcare (Basel)       Date:  2014-02-19
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.