Literature DB >> 22908946

The effect of temperature on the mechanical behavior of nickel-titanium orthodontic initial archwires.

Luca Lombardo1, Giorgia Toni, Filippo Stefanoni, Francesco Mollica, Maria Paola Guarneri, Giuseppe Siciliani.   

Abstract

OBJECTIVES: To investigate and compare the characteristics of commonly used types of traditional and heat-activated initial archwires at different temperatures by plotting their load/deflection graphs and quantifying three parameters describing the discharge plateau phase.
MATERIALS AND METHODS: Forty-eight archwires of cross-sectional diameters ranging from 0.010 inches to 0.016 inches were obtained from seven different manufacturers. A modified three-point wire-bending test was performed on three analogous samples of each type of archwire at 55°C and 5°C, simulating an inserted archwire that is subjected to cold or hot drinks during a meal. For each resulting load/deflection curve the plateau section was isolated and the mean value of each parameter for each type of wire was obtained.
RESULTS: Permanent strain was exhibited by all wires tested at 55°C. Statistically significant differences were found between almost all wires for the three considered parameters when tested at 55°C and 5°C. Loads were greater at 55°C than at 5°C. Differences were also found between traditional and heat-activated archwires, the latter of which generated longer plateaus at 55°C, shorter plateaus at 5°C, and lighter mean forces at both temperatures. The increase in average force seen with increasing diameter tended to be rather stable at both temperatures.
CONCLUSIONS: All nickel-titanium wires tested showed a significant change related to temperature in terms of behavior and force for both traditional and heat-activated wires. Stress under high temperatures can induce permanent strain, whereas the residual strain detected at low temperatures can be recovered from as temperature increases.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22908946      PMCID: PMC8793662          DOI: 10.2319/040612-287.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  18 in total

1.  The effect of short-term temperature changes on superelastic nickel-titanium archwires activated in orthodontic bending.

Authors:  T R Meling; J Odegaard
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-03       Impact factor: 2.650

Review 2.  Pseudoelasticity and thermoelasticity of nickel-titanium alloys: a clinically oriented review. Part I: Temperature transitional ranges.

Authors:  M Santoro; O F Nicolay; T J Cangialosi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-06       Impact factor: 2.650

3.  Force levels of nickel titanium initial archwires.

Authors:  Jeff Berger; Tom Waram
Journal:  J Clin Orthod       Date:  2007-05

4.  Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic brackets.

Authors:  Firas Elayyan; Nick Silikas; David Bearn
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-02       Impact factor: 2.650

5.  Properties of superelastic wires and their relevance to orthodontic treatment.

Authors:  D Segner; D Ibe
Journal:  Eur J Orthod       Date:  1995-10       Impact factor: 3.075

6.  The characteristics of super-elastic Ni-Ti wires in three-point bending. Part I: The effect of temperature.

Authors:  R I Tonner; N E Waters
Journal:  Eur J Orthod       Date:  1994-10       Impact factor: 3.075

7.  Elastic modulus of a triple-stranded stainless steel arch wire via three- and four-point bending.

Authors:  R P Kusy; G J Dilley
Journal:  J Dent Res       Date:  1984-10       Impact factor: 6.116

8.  The effect of ligation on the load deflection characteristics of nickel titanium orthodontic wire.

Authors:  Shugo Kasuya; Satoshi Nagasaka; Ai Hanyuda; Sadao Ishimura; Ayao Hirashita
Journal:  Eur J Orthod       Date:  2007-09-14       Impact factor: 3.075

Review 9.  Mechanical properties and clinical applications of orthodontic wires.

Authors:  S Kapila; R Sachdeva
Journal:  Am J Orthod Dentofacial Orthop       Date:  1989-08       Impact factor: 2.650

10.  Load deflection characteristics and force level of nickel titanium initial archwires.

Authors:  Luca Lombardo; Matteo Marafioti; Filippo Stefanoni; Francesco Mollica; Giuseppe Siciliani
Journal:  Angle Orthod       Date:  2011-09-13       Impact factor: 2.079

View more
  7 in total

1.  Thermo-Mechanical Properties of Glass Fiber Reinforced Shape Memory Polyurethane for Orthodontic Application.

Authors:  Yun-Feng Liu; Jian-Lei Wu; Shan-Ling Song; Li-Xin Xu; Jie Chen; Wei Peng
Journal:  J Mater Sci Mater Med       Date:  2018-08-31       Impact factor: 3.896

2.  Evaluating the Elemental Composition, Transformation Behavior, Crystalline Structure, and Mechanical Properties of Three 0.016-Inch by 0.022-Inch Nickel-Titanium Archwires: An In Vitro Study.

Authors:  Odayy Al-Horini; Mohammad Y Hajeer; Feras Baba
Journal:  Cureus       Date:  2022-07-24

3.  Deflection test evaluation of different lots of the same nickel-titanium wire commercial brand.

Authors:  Murilo Gaby Neves; Fabrício Viana Pereira Lima; Júlio de Araújo Gurgel; Célia Regina Maio Pinzan-Vercelino; Fernanda Soares Rezende; Gustavo Antônio Martins Brandão
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb

4.  The force effects of two types of polyethylene terephthalate glyc-olmodified clear aligners immersed in artificial saliva.

Authors:  Biao Xiang; Xingxing Wang; Gang Wu; Yichen Xu; Menghan Wang; Yanjing Yang; Qingyu Wang
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

5.  The influence of distal-end heat treatment on deflection of nickel-titanium archwire.

Authors:  Marcelo Faria da Silva; Célia Regina Maia Pinzan-Vercelino; Júlio de Araújo Gurgel
Journal:  Dental Press J Orthod       Date:  2016 Jan-Feb

6.  Evaluation of biofilm accumulation on and deactivation force of orthodontic Ni-Ti archwires before and after exposure to an oral medium: A prospective clinical study.

Authors:  Diogo M Sapata; Adilson L Ramos; Sérgio Sábio; David Normando; Renata C Pascotto
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2020

7.  Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro study.

Authors:  Mario Palone; Mattia Longo; Niki Arveda; Michele Nacucchi; Fabio De Pascalis; Giorgio Alfredo Spedicato; Giuseppe Siciliani; Luca Lombardo
Journal:  Korean J Orthod       Date:  2021-03-25       Impact factor: 1.372

  7 in total