Literature DB >> 10394385

The NAC proton treatment planning system.

A N Schreuder1, D T Jones, J E Symons, E A De Kock, J K Hough, J Wilson, F J Vernimmen, W Schlegel, A Höss, M Lee.   

Abstract

A three-dimensional proton treatment planning system called PROXELPLAN has been used at the National Accelerator Centre (NAC) since October 1994. This system is entirely based on the VOXELPLAN planning system, developed at the Deutches Krebsforschungszentrum (DKFZ), Heidelberg, Germany. The VOXELPLAN system provides the treatment planning infrastructure while the proton dose distributions are calculated using a software module that was initially developed at the Royal Marsden Hospital, UK. The proton module has been extensively modified and refined. It uses a rayline-tracing algorithm which is suitable for planning current treatments but is not sufficiently dynamic to accommodate the use of compensators. A sophisticated pencil beam algorithm is currently under development.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10394385     DOI: 10.1007/bf03038876

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  7 in total

1.  Differential-pencil-beam dose calculations for charged particles.

Authors:  P L Petti
Journal:  Med Phys       Date:  1992 Jan-Feb       Impact factor: 4.071

2.  The calibration of CT Hounsfield units for radiotherapy treatment planning.

Authors:  U Schneider; E Pedroni; A Lomax
Journal:  Phys Med Biol       Date:  1996-01       Impact factor: 3.609

3.  Proton beam penumbra: effects of separation between patient and beam modifying devices.

Authors:  M M Urie; J M Sisterson; A M Koehler; M Goitein; J Zoesman
Journal:  Med Phys       Date:  1986 Sep-Oct       Impact factor: 4.071

4.  Degradation of the Bragg peak due to inhomogeneities.

Authors:  M Urie; M Goitein; W R Holley; G T Chen
Journal:  Phys Med Biol       Date:  1986-01       Impact factor: 3.609

5.  [Three-dimensional radiation planning. Studies on clinical integration].

Authors:  G Gademann; W Schlegel; J Bürkelbach; C Laier; S Behrens; S Brieger; M Wannenmacher
Journal:  Strahlenther Onkol       Date:  1993-03       Impact factor: 3.621

6.  A comparison of proton and megavoltage X-ray treatment planning for prostate cancer.

Authors:  M Lee; C Wynne; S Webb; A E Nahum; D Dearnaley
Journal:  Radiother Oncol       Date:  1994-12       Impact factor: 6.280

7.  Fractionated stereotactically guided radiotherapy of head and neck tumors: a report on clinical use of a new system in 195 cases.

Authors:  G Gademann; W Schlegel; J Debus; L Schad; T Bortfeld; K H Höver; W J Lorenz; M Wannenmacher
Journal:  Radiother Oncol       Date:  1993-11       Impact factor: 6.280

  7 in total