Literature DB >> 8465250

[Three-dimensional radiation planning. Studies on clinical integration].

G Gademann1, W Schlegel, J Bürkelbach, C Laier, S Behrens, S Brieger, M Wannenmacher.   

Abstract

The routine use of three-dimensional treatment planning was evaluated in a clinical project funded by the German Krebshilfe at the Radiological Department of the University of Heidelberg. 166 patients entered the prospective study within 14 months, 155 of them were treated according to the 3D-plans. More than 50% of the patients had thoracic tumors, followed by pelvic tumors. One medicine physicist and one specially trained technician performed the treatment planning. The target volumes were contoured in the CT slices at the planning computer by the responsible radiotherapists. A mean of 6.5 hours per patient was necessary for all planning procedures, however, this time consumption shows a trend toward less time of only four hours including about ten optimization steps. Meanwhile approximately 20 to 30% of all computer assisted planning are performed in 3D, corresponding to about one plan per day. The achieved time consumption is a clinically accepted quantity, that allows the introduction of 3D-planning into clinical routine.

Entities:  

Mesh:

Year:  1993        PMID: 8465250

Source DB:  PubMed          Journal:  Strahlenther Onkol        ISSN: 0179-7158            Impact factor:   3.621


  5 in total

1.  Treatment planning for the heavy-ion facility at GSI.

Authors:  O Jäkel; M Krämer; G H Hartmann; P Heeg; C P Karger; G Kraft
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

2.  The NAC proton treatment planning system.

Authors:  A N Schreuder; D T Jones; J E Symons; E A De Kock; J K Hough; J Wilson; F J Vernimmen; W Schlegel; A Höss; M Lee
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

3.  Treatment planning for light ions: how to take into account relative biological effectiveness (RBE).

Authors:  O Jäkel; J Debus; M Krämer; M Scholz; G Kraft
Journal:  Strahlenther Onkol       Date:  1999-06       Impact factor: 3.621

4.  [Planned 3-dimensional low-volume conformal irradiation of a local prostatic carcinoma].

Authors:  S Wachter; N Gerstner; K Dieckmann; M Stampfer; R Hawliczek; R Pötter
Journal:  Strahlenther Onkol       Date:  1997-05       Impact factor: 3.621

5.  [A comparison of CT-supported 3D planning with simulator planning in the pelvic irradiation of primary cervical carcinoma].

Authors:  T H Knocke; B Pokrajac; C Fellner; R Pötter
Journal:  Strahlenther Onkol       Date:  1999-02       Impact factor: 3.621

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.