Literature DB >> 10386646

Diode-light transillumination for ophthalmic plaque localization around juxtapapillary choroidal melanomas.

P T Finger1, R Iezzi, M L Esteveo, A Szechter, R B Rosen, A Berson.   

Abstract

PURPOSE: An evaluation of plaque-mounted diode-light transillumination (DLT) for localization of episcleral plaques beneath juxtapapillary tumors. METHODS AND MATERIALS: Two patients scheduled for radiotherapy for juxtapapillary melanomas were offered DLT as an additional method of ophthalmic plaque localization. Plaques were constructed by affixing 4 non-heat producing, light-emitting diodes with their apertures flush with the episcleral outer surface of the plaque's rim. Bio-implantable epoxy was used to encapsulate the electronic components. Then the plaques were loaded with 103Pd seeds. After the eye-plaques were sewn to the episclera covering the base of the intraocular tumors; the diode-lights were illuminated, viewed and recorded. Photodocumentation of the relative position of the 4 lights around tumor's base was obtained in both cases.
RESULTS: Digital images of plaque-mounted diode retro-transillumination were obtained. No evidence of diode-light toxicity was noted. Both tumors were found to be covered by the ophthalmic plaques.
CONCLUSION: Juxtapapillary tumors are often difficult or impossible to visualize with standard transillumination techniques and have been associated with poor local control rates. We have developed plaque-mounted DLT in an effort to improve ophthalmic plaque localization. Retrobulbar transillumination was viewed by indirect ophthalmoscopy and recorded with video-imaging. This technique provides unique photographic documentation of episcleral plaque localization beneath juxtapapillary tumors.

Entities:  

Mesh:

Year:  1999        PMID: 10386646     DOI: 10.1016/s0360-3016(99)00064-4

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  4 in total

1.  Finger's "slotted" eye plaque for radiation therapy: treatment of juxtapapillary and circumpapillary intraocular tumours.

Authors:  Paul T Finger
Journal:  Br J Ophthalmol       Date:  2007-02-27       Impact factor: 4.638

2.  A Modified Dummy Plaque for the Accurate Placement of Ruthenium-106 Plaques in Brachytherapy of Intraocular Tumours.

Authors:  Jørgen Krohn
Journal:  Ocul Oncol Pathol       Date:  2015-06-05

3.  Clinical evaluation of a paper chart for predicting ruthenium plaque placement in relation to choroidal melanoma.

Authors:  I Rospond-Kubiak; J Kociecki; B Damato
Journal:  Eye (Lond)       Date:  2017-09-29       Impact factor: 3.775

4.  Cherenkov Luminescence Imaging for Assessment of Radioactive Plaque Position in Brachytherapy of Uveal Melanoma: An In Vivo Feasibility Study.

Authors:  Jørgen Krohn; Yi-Chun Chen; Nils Ole Stabo-Eeg; Børge Hamre
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283

  4 in total