Literature DB >> 28960216

Clinical evaluation of a paper chart for predicting ruthenium plaque placement in relation to choroidal melanoma.

I Rospond-Kubiak1, J Kociecki1, B Damato2,3.   

Abstract

PurposeTo determine the accuracy of estimated tumour location and required plaque position using fundus diagrams, and to evaluate their applicability in daily clinical practice.Patients and methodsBetween September 2013 and March 2016, all patients treated with ruthenium plaque brachytherapy for choroidal melanoma at the Department of Ophthalmology in Poznań underwent pretreatment planning with the use of printed or electronic fundus diagrams www.oculonco.comThe estimated distances were then verified intraoperatively.ResultsThere were 40 eyes of 40 patients: 15 men, 25 women, with a median age of 61 years (range: 21-88). The median longitudinal basal diameter (LBD) of the treated melanomas was 10.4 mm (range: 6.5-14.9) and the median thickness was 4.1 mm (range: 1.9-6). The final postition of the anterior tumour margin was within 1 mm of the estimated location in 39 cases (97 %), and within 2 mm in 1 case (3 %). Median follow-up was 15 months (range: 3-36). By the close of the study, there was one local tumour recurrence (3%) and one patient died of unrelated cause 1 year after treatment. No patient developed metastases by study close.ConclusionsThe plaque planning system using the paper fundus diagrams proved to be accurate, easily applicable and should aid plaque placement where computer modelling is not possible.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28960216      PMCID: PMC5811722          DOI: 10.1038/eye.2017.205

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  7 in total

1.  Diode-light transillumination for ophthalmic plaque localization around juxtapapillary choroidal melanomas.

Authors:  P T Finger; R Iezzi; M L Esteveo; A Szechter; R B Rosen; A Berson
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

2.  Outcomes of choroidal melanomas treated with eye physics: a 20-year review.

Authors:  Jesse L Berry; Savita V Dandapani; Marta Stevanovic; Thomas C Lee; Melvin Astrahan; A Linn Murphree; Jonathan W Kim
Journal:  JAMA Ophthalmol       Date:  2013-11       Impact factor: 7.389

3.  A Modified Dummy Plaque for the Accurate Placement of Ruthenium-106 Plaques in Brachytherapy of Intraocular Tumours.

Authors:  Jørgen Krohn
Journal:  Ocul Oncol Pathol       Date:  2015-06-05

4.  Treatment of choroidal melanoma: MR imaging in the assessment of radioactive plaque position.

Authors:  S L Hanna; M A Lemmi; J W Langston; J Fontanesi; H L Brooks; S Gronemeyer
Journal:  Radiology       Date:  1990-09       Impact factor: 11.105

5.  Intraoperative echographic localization of iodine 125 episcleral radioactive plaques for posterior uveal melanoma.

Authors:  J W Harbour; T G Murray; S F Byrne; J R Hughes; E K Gendron; F J Ehlies; A M Markoe
Journal:  Retina       Date:  1996       Impact factor: 4.256

6.  Eccentric ruthenium plaque radiotherapy of posterior choroidal melanoma.

Authors:  Andrea Russo; Michela Laguardia; Bertil Damato
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-23       Impact factor: 3.117

7.  Evaluation of the surgical learning curve for I-125 episcleral plaque placement for the treatment of posterior uveal melanoma: a two decade review.

Authors:  Nisha V Shah; Samuel K Houston; Timothy G Murray; Arnold M Markoe
Journal:  Clin Ophthalmol       Date:  2012-03-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.