Literature DB >> 10382775

Thoracic pedicle screw placement guided by computed tomographic measurements.

R Xu1, N A Ebraheim, M E Shepherd, R A Yeasting.   

Abstract

Cadaveric pedicle screw placement guided by the measurements from axial computed tomography (CT) scans in the thoracic spine was assessed in this study. Axial CT scans were performed on four cadaveric thoracic spines, and the measurements included the pedicle transverse angle, inner pedicle width, and distance between the midline of the vertebra and the pedicle axis on the dorsal aspect of the lamina. With utilization of the data from CT scans, screws were directly placed into the thoracic pedicle from T1 to T10. Screw penetration of the pedicle was determined by gross examination. The results showed that the largest pedicle transverse angle was found at the levels of T1-2, and the smallest occurred at the T3 through T8 levels. The value of the pedicle inner width was quite different between specimens with a minimum of 3.0 mm at T4 and a maximum of 9.2 mm at T10. Gross examination of the pedicle showed that 13 (16.3%) of 80 screws penetrated the pedicle wall, with a Grade I penetration in 11 pedicles and a Grade II penetration in 2 pedicles. Screw penetration of the medial wall was found in four pedicles and penetration of the lateral wall was noted in nine pedicles. No screw penetration of the superior and inferior walls of the pedicle was identified in any of the four specimens. Thoracic pedicle screw placement guided by the measurements from axial CT scans significantly reduced the incidence of pedicle penetration. Axial CT measurements of the pedicle inner diameter and transverse angle as well as the starting point for screw insertion are recommended if pedicle screw fixation is intended in the thoracic spine.

Entities:  

Mesh:

Year:  1999        PMID: 10382775

Source DB:  PubMed          Journal:  J Spinal Disord        ISSN: 0895-0385


  7 in total

1.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

2.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

3.  Financial analysis of circumferential fusion versus posterior-only with thoracic pedicle screw constructs for main thoracic idiopathic curves between 70 degrees and 100 degrees.

Authors:  Scott J Luhmann; Lawrence G Lenke; Yongjung J Kim; Keith H Bridwell; Mario Schootman
Journal:  J Child Orthop       Date:  2008-02-14       Impact factor: 1.548

Review 4.  Methods to determine pedicle screw placement accuracy in spine surgery: a systematic review.

Authors:  Ahmed A Aoude; Maryse Fortin; Rainer Figueiredo; Peter Jarzem; Jean Ouellet; Michael H Weber
Journal:  Eur Spine J       Date:  2015-03-07       Impact factor: 3.134

5.  Inserting pedicle screws in the upper thoracic spine without the use of fluoroscopy or image guidance. Is it safe?

Authors:  Constantin Schizas; Nicolas Theumann; Victor Kosmopoulos
Journal:  Eur Spine J       Date:  2006-11-15       Impact factor: 3.134

6.  Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine.

Authors:  Jean-Marc Mac-Thiong; Hubert Labelle; Marcel Rooze; Véronique Feipel; Carl-Eric Aubin
Journal:  Eur Spine J       Date:  2003-05-29       Impact factor: 3.134

7.  Placement of pedicle screws in thoracic idiopathic scoliosis: a magnetic resonance imaging analysis of screw placement relative to structures at risk.

Authors:  Ahmet Yilmaz Sarlak; Levent Buluç; Hasan Tahsin Sarisoy; Kaya Memişoğlu; Bilgehan Tosun
Journal:  Eur Spine J       Date:  2008-02-27       Impact factor: 3.134

  7 in total