Literature DB >> 10372525

In vivo diffusion characteristics of rat spinal cord.

D A Fenyes1, P A Narayana.   

Abstract

Complete apparent diffusion tensor (ADTs) of spinal cord was measured in vivo in nine rats at 2.0 T. Two rotationally invariant parameters, the trace, which is a measure of the mean diffusivity, and the lattice index (LI), which reflects the degree of orientation coherence of tissue, have been estimated from the ADT. The mean white matter (WM) trace value (3.05 +/- 0.26 mm2/sec) was found to be substantially higher than the gray matter (GM) trace (2.36 +/- 0.39 mm2/sec), in contrast with the published results on fixed, excised cord. Statistically significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LI = 0.67 +/- 0.06) than in the GM (LI = 0.51 +/- 0.05).

Entities:  

Mesh:

Year:  1999        PMID: 10372525     DOI: 10.1016/s0730-725x(98)00220-3

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  6 in total

1.  Diffusion tractography of the cervical spinal cord by using parallel imaging.

Authors:  Kazuhiro Tsuchiya; Akira Fujikawa; Yuriko Suzuki
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

2.  High-resolution MR imaging of the rat spinal cord in vivo in a wide-bore magnet at 17.6 Tesla.

Authors:  V C Behr; T Weber; T Neuberger; M Vroemen; N Weidner; U Bogdahn; A Haase; P M Jakob; C Faber
Journal:  MAGMA       Date:  2004-10-23       Impact factor: 2.310

3.  Serial Diffusion Tensor Imaging In Vivo Predicts Long-Term Functional Recovery and Histopathology in Rats following Different Severities of Spinal Cord Injury.

Authors:  Samir P Patel; Taylor D Smith; Jenna L VanRooyen; David Powell; David H Cox; Patrick G Sullivan; Alexander G Rabchevsky
Journal:  J Neurotrauma       Date:  2016-02-11       Impact factor: 5.269

Review 4.  The current state-of-the-art of spinal cord imaging: methods.

Authors:  P W Stroman; C Wheeler-Kingshott; M Bacon; J M Schwab; R Bosma; J Brooks; D Cadotte; T Carlstedt; O Ciccarelli; J Cohen-Adad; A Curt; N Evangelou; M G Fehlings; M Filippi; B J Kelley; S Kollias; A Mackay; C A Porro; S Smith; S M Strittmatter; P Summers; I Tracey
Journal:  Neuroimage       Date:  2013-05-14       Impact factor: 6.556

5.  Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

Authors:  Deepu R Pillai; Robin M Heidemann; Praveen Kumar; Nagesh Shanbhag; Titus Lanz; Michael S Dittmar; Beatrice Sandner; Christoph P Beier; Norbert Weidner; Mark W Greenlee; Gerhard Schuierer; Ulrich Bogdahn; Felix Schlachetzki
Journal:  PLoS One       Date:  2011-02-07       Impact factor: 3.240

6.  In vivo mouse spinal cord imaging using echo-planar imaging at 11.75 T.

Authors:  Virginie Callot; Guillaume Duhamel; Patrick J Cozzone
Journal:  MAGMA       Date:  2007-07-28       Impact factor: 2.310

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.