Literature DB >> 10371453

Correction for EPI distortions using multi-echo gradient-echo imaging.

N K Chen1, A M Wyrwicz.   

Abstract

A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. With the proposed post-processing algorithm of multi-channel modulation, distortions may be corrected without unwrapping the phase discontinuities in the derived field map, a process that usually restricts the application of other field map-based correction methods. Results from phantom and animal experiments at 4.7 T demonstrate the efficiency of the method in reducing the geometrical distortions in gradient-echo EPI.

Mesh:

Year:  1999        PMID: 10371453     DOI: 10.1002/(sici)1522-2594(199906)41:6<1206::aid-mrm17>3.0.co;2-l

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

1.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

2.  Correlation of white matter diffusivity and anisotropy with age during childhood and adolescence: a cross-sectional diffusion-tensor MR imaging study.

Authors:  Vincent J Schmithorst; Marko Wilke; Bernard J Dardzinski; Scott K Holland
Journal:  Radiology       Date:  2002-01       Impact factor: 11.105

3.  Event-related single-shot volumetric functional magnetic resonance inverse imaging of visual processing.

Authors:  Fa-Hsuan Lin; Thomas Witzel; Joseph B Mandeville; Jonathan R Polimeni; Thomas A Zeffiro; Douglas N Greve; Graham Wiggins; Lawrence L Wald; John W Belliveau
Journal:  Neuroimage       Date:  2008-04-23       Impact factor: 6.556

4.  Comparison of EPI distortion correction methods in diffusion tensor MRI using a novel framework.

Authors:  M Wu; L C Chang; L Walker; H Lemaitre; A S Barnett; S Marenco; C Pierpaoli
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

5.  Correction of B0 susceptibility induced distortion in diffusion-weighted images using large-deformation diffeomorphic metric mapping.

Authors:  Hao Huang; Can Ceritoglu; Xin Li; Anqi Qiu; Michael I Miller; Peter C M van Zijl; Susumu Mori
Journal:  Magn Reson Imaging       Date:  2008-05-21       Impact factor: 2.546

6.  An improved PSF mapping method for EPI distortion correction in human brain at ultra high field (7T).

Authors:  Jun-Young Chung; Myung-Ho In; Se-Hong Oh; Maxim Zaitsev; Oliver Speck; Zang-Hee Cho
Journal:  MAGMA       Date:  2011-04-21       Impact factor: 2.310

7.  Distortion correction for diffusion-weighted MRI tractography and fMRI in the temporal lobes.

Authors:  Karl V Embleton; Hamied A Haroon; David M Morris; Matthew A Lambon Ralph; Geoff J M Parker
Journal:  Hum Brain Mapp       Date:  2010-10       Impact factor: 5.038

8.  Highly accelerated PSF-mapping for EPI distortion correction with improved fidelity.

Authors:  Myung-Ho In; Oliver Speck
Journal:  MAGMA       Date:  2011-08-04       Impact factor: 2.310

9.  Regularized field map estimation in MRI.

Authors:  Amanda K Funai; Jeffrey A Fessler; Desmond T B Yeo; Valur T Olafsson; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2008-10       Impact factor: 10.048

10.  Linear constraint minimum variance beamformer functional magnetic resonance inverse imaging.

Authors:  Fa-Hsuan Lin; Thomas Witzel; Thomas A Zeffiro; John W Belliveau
Journal:  Neuroimage       Date:  2008-07-11       Impact factor: 6.556

View more