Literature DB >> 10350314

Temporal bone: comparison of isotropic helical CT and conventional direct axial and coronal CT.

K S Caldemeyer1, K Sandrasegaran, C N Shinaver, V P Mathews, R R Smith, K K Kopecky.   

Abstract

OBJECTIVE: The objective of the study was to compare helical CT (with reformation of coronal images from the axial data set) with conventional direct axial and coronal CT of the temporal bones. SUBJECTS AND METHODS: Nineteen patients underwent both conventional 1-mm direct axial and coronal CT and helical 0.5-mm axial CT. The helical data set was reconstructed at 0.2-mm increments, and axial and coronal images were reconstructed in a plane similar to that of the conventional study, with a slice width of 0.5 mm and 0.5-mm increments. Forty small structures were evaluated independently by three observers, who were unaware of the method of imaging. Observers graded the 40 structures using a modified Likert scale. The graded differences between the two techniques were evaluated using a paired t test. Correlation between observers' gradings was evaluated using analysis of variance.
RESULTS: The helical CT technique scored significantly higher than the conventional technique for many individual structures and groups of structures (scutum [p = .041], stapes footplate [p = .006], stapes crura [p = .004], oval window [p = .026], crista falciformis [p = .006], whole temporal bone [P = .012], middle ear [p = .033], inner ear [p = .021], ossicles [p = .044], and stapes [p = .010]). The correlation coefficient among observers was .91 for the whole temporal bone.
CONCLUSION: Helical CT using 0.5-mm technique and reconstruction produces diagnostic images comparable with or superior to conventional 1-mm technique because helical CT can obtain thinner slices.

Entities:  

Mesh:

Year:  1999        PMID: 10350314     DOI: 10.2214/ajr.172.6.10350314

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  6 in total

1.  Current multiplanar imaging of the stapes.

Authors:  Philippe Henrot; Sandrine Iochum; Toufik Batch; Laurent Coffinet; Alain Blum; Jacques Roland
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

2.  Radiation dose to the lens using different temporal bone CT scanning protocols.

Authors:  Y Niu; Z Wang; Y Liu; Z Liu; V Yao
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-05       Impact factor: 3.825

3.  Comparison of a Photon-Counting-Detector CT with an Energy-Integrating-Detector CT for Temporal Bone Imaging: A Cadaveric Study.

Authors:  W Zhou; J I Lane; M L Carlson; M R Bruesewitz; R J Witte; K K Koeller; L J Eckel; R E Carter; C H McCollough; S Leng
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-09       Impact factor: 3.825

4.  Comparison of 128-section single-shot technique with conventional spiral multisection CT for imaging of the temporal bone.

Authors:  S A Schwab; S Eberle; B Adamietz; M A Kuefner; M Kramer; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2011-03-31       Impact factor: 3.825

5.  Improving depiction of temporal bone anatomy with low-radiation dose CT by an integrated circuit detector in pediatric patients: a preliminary study.

Authors:  Jingzhen He; Yuliang Zu; Qing Wang; Xiangxing Ma
Journal:  Medicine (Baltimore)       Date:  2014-12       Impact factor: 1.889

6.  Multislice Spiral Computer Tomography Findings of Simple Congenital Middle Ear Malformations.

Authors:  Chunmiao Kang; Lei Han; Yunyun Zhao; Pengfeng Sun; Ming Gao; Mingyue Ma; Xiaoping Wu; Junle Yang; Hongsheng Liu; Jiping Dong
Journal:  Contrast Media Mol Imaging       Date:  2022-08-03       Impact factor: 3.009

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.