Literature DB >> 10330641

Changes in intraocular lens position after neodymium: YAG capsulotomy.

O Findl1, W Drexler, R Menapace, M Georgopoulos, G Rainer, C K Hitzenberger, A F Fercher.   

Abstract

PURPOSE: To quantify changes in intraocular lens (IOL) position caused by neodymium: YAG (Nd:YAG) capsulotomy with 3 IOL styles.
SETTING: Department of Ophthalmology, University of Vienna, Austria.
METHODS: In a prospective study, anterior chamber depth (ACD) was measured by dualbeam partial coherence interferometry (PCI) in 32 pseudophakic eyes of 32 patients with posterior capsule opacification before and immediately after planned capsulotomy under mydriasis. Patients were divided into 3 groups with the following IOL styles: 1-piece poly(methyl methacrylate) (PMMA), 3-piece foldable, and plate haptic.
RESULTS: The capsulotomy induced a backward IOL movement in all 32 eyes (mean 25 microns; range 9 to 55 microns). It was more pronounced in eyes with plate-haptic IOLs than in those with the other styles. Precision of ACD measurement by PCI was 4 microns. Changes in ACD correlated significantly with capsulotomy size but not with preoperative lens-capsule distance.
CONCLUSION: Capsulotomy caused a backward movement of the IOL, which was more pronounced with plate-haptic IOLs than with 1-piece PMMA and 3-piece foldable IOLs. Since the magnitude of IOL movement in this study population was small, a hyperopic shift in refraction after capsulotomy will usually be small and not clinically relevant.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10330641     DOI: 10.1016/s0886-3350(99)00010-3

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  18 in total

1.  Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens.

Authors:  David P Piñero; Vicente J Camps; María L Ramón; Verónica Mateo; Rafael J Pérez-Cambrodí
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

2.  Influence of lens position as detected by an anterior segment analysis system on postoperative refraction in cataract surgery.

Authors:  Jia-Ju Zhang; Jian-Qing Li; Chen Li; Yi-Hong Cao; Pei-Rong Lu
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

3.  Influence of intraocular lens material and design on postoperative intracapsular cellular reactivity.

Authors:  D J Apple
Journal:  Trans Am Ophthalmol Soc       Date:  2000

4.  The role of anterior hyaloid face integrity on retinal complications during Nd: YAG laser capsulotomy.

Authors:  Erhan Ozyol; Pelin Ozyol; Beyza Doğanay Erdoğan; Mehmet Onen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-11-21       Impact factor: 3.117

5.  Postoperative refractive error after phacovitrectomy for epiretinal membrane with and without macular oedema.

Authors:  Andreas Frings; Simon Dulz; Christos Skevas; Birthe Stemplewitz; Stephan J Linke; Gisbert Richard; Lars Wagenfeld
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-02-06       Impact factor: 3.117

6.  Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position.

Authors:  David P Piñero; Vicente J Camps; MarIa L Ramón; Verónica Mateo; Rafael J Pérez-CambrodI
Journal:  Indian J Ophthalmol       Date:  2015-05       Impact factor: 1.848

7.  The effect of Nd:YAG laser treatment of posterior capsule opacification on anterior chamber depth and refraction in pseudophakic eyes.

Authors:  Bharkbhum Khambhiphant; Chayata Liumsirijarern; Piyada Saehout
Journal:  Clin Ophthalmol       Date:  2015-03-25

8.  Refractive change following pseudophakic vitrectomy.

Authors:  Sinead Byrne; James Ng; Anthony Hildreth; Jean-Pierre Danjoux; David Hw Steel
Journal:  BMC Ophthalmol       Date:  2008-10-13       Impact factor: 2.209

9.  The Effect of ND:YAG Laser Posterior Capsulotomy Size on Refraction, Intraocular Pressure, and Macular Thickness.

Authors:  Eyyup Karahan; Ibrahim Tuncer; Mehmet Ozgur Zengin
Journal:  J Ophthalmol       Date:  2014-03-03       Impact factor: 1.909

10.  Comparative evaluation of rotational stability and visual outcome of toric intraocular lenses with and without a capsular tension ring.

Authors:  Anju Rastogi; Samreen Khanam; Yashpal Goel; Prolima Thacker; Prateek Kumar
Journal:  Indian J Ophthalmol       Date:  2018-03       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.