Bharkbhum Khambhiphant1, Chayata Liumsirijarern2, Piyada Saehout1.
Abstract
PURPOSE: This was a prospective descriptive study to determine the changes in intraocular lens (IOL) position after neodymium-doped yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy by measuring anterior chamber depth (ACD) and refraction, including the spherical equivalent (SE) and cylinder.Entities:
Keywords: anterior chamber depth; neodymium-doped yttrium–aluminum–garnet; posterior capsule opacification; pseudophakia; refraction
Year: 2015 PMID: 25848207 PMCID: PMC4378868 DOI: 10.2147/OPTH.S80220
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Figure 1Anterior segment photography immediately after Nd:YAG laser posterior capsulotomy (430×407).
Abbreviation: Nd:YAG, neodymium-doped yttrium–aluminum–garnet.
Patients’ characteristics
| Mean | Range | SD | |
|---|---|---|---|
| Age (years) | 68.4 | 44–86 | 8.9 |
| Time interval for cataract surgery to capsulotomy (months) | 28.3 | 5–71 | 14.9 |
| Types of IOLs (number of eyes) | |||
| One-piece foldable | 23 | ||
| Three-piece foldable | 22 | ||
| One-piece PMMA | 2 | ||
| Energy level (mJ) | 0.8 | ||
| Total energy use (mJ) | 12.6 | 5.6–29.5 | 5.4 |
| Total spot count (number) | 15.4 | 7–39 | 6.7 |
Abbreviations: SD, standard deviation; IOL, intraocular lens; PMMA, poly(methyl methacrylate).
ACD over time
| ACD (mm)
| |||
|---|---|---|---|
| Before Laser | After laser, 1 week | After laser, 3 months | |
| Mean (SD) | 3.74 (0.38) | 3.79 (0.48) | 3.82 (0.48) |
| Difference | 0.05 | 0.08 | |
| Changes (%) | 1.3% | 2.2% | |
| 0.58 | 0.26 | ||
Notes:
Paired t-test compared with ACD before treatment. Repeated analysis of variance; P-value =0.58.
Abbreviations: ACD, anterior chamber depth; SD, standard deviation.
SE over time
| SE (diopters)
| |||
|---|---|---|---|
| Before laser | After laser, 1 week | After laser, 3 months | |
| Mean (SD) | −0.19 (0.52) | −0.24 (0.50) | −0.21 (0.54) |
| Difference | −0.06 | −0.02 | |
| Change (%) | 32.4% | 10.8% | |
| 0.09 | 0.52 | ||
Notes:
Paired t-test compared with SE before treatment. Repeated analysis of variance; P-value =0.27.
Abbreviations: SE, spherical equivalent; SD, standard deviation.
Cylindrical power over time
| Cylindrical power (diopters)
| |||
|---|---|---|---|
| Before laser | After laser, 1 week | After laser, 3 months | |
| Mean (SD) | −1.16 (0.69) | −1.00 (0.65) | −1.14 (1.06) |
| Difference | 0.16 | 0.02 | |
| Changes (%) | 13.8% | 2.1% | |
| 0.008 | 0.58 | ||
Notes:
Paired t-test compared with cylindrical power before treatment. Repeated analysis of variance; P-value =0.01.
Abbreviation: SD, standard deviation.
Types of IOL and SE, cylinder, and ACD change at 3 months
| Type of IOL | Mean SE change (SD) | Mean cylinder change (SD) | Mean ACD change (SD) |
|---|---|---|---|
| One-piece (25 eyes) | −0.06 (0.30) | 0.06 (0.35) | 0.06 (0.52) |
| Three-piece (22 eyes) | 0.01 (0.20) | −0.01 (0.30) | 0.11 (0.47) |
| 0.32 | 0.25 | 0.71 |
Abbreviations: IOL, intraocular lens; SE, spherical equivalent; ACD, anterior chamber depth; SD, standard deviation.