Literature DB >> 10329242

Asymmetric adiabatic pulses for NH selection.

T L Hwang1, P C van Zijl, M Garwood.   

Abstract

Many types of NMR experiments demand the use of frequency-selective pulses to invert magnetization within discrete frequency limits. For certain experiments, only one side of the inversion band must be sharply demarcated, in which case this transition bandwidth can be narrowed when using an asymmetric adiabatic full passage. In the present study, a highly efficient asymmetric adiabatic full passage was created from a combination of two adiabatic half passages which used different modulation functions (HS12 and tanh/tan). Each adiabatic half passage occupied a different amount of time in the total pulse and performed one-half of the inversion. On one side, HS12 produced a sharp transition between inverted and noninverted states which was approximately 2.5 times narrower than the transition bandwidth afforded by a symmetric hyperbolic secant pulse of equal length. On the other side of the narrow transition band, the tanh/tan pulse achieved broadband inversion. These asymmetric pulses were applied to select NH groups immediately adjacent to the water signal in water-flip-back HSQC experiments using a double spin echo for the reverse INEPT step. Copyright 1999 Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10329242     DOI: 10.1006/jmre.1999.1713

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  11 in total

1.  Two-dimensional linear-combination model fitting of magnetic resonance spectra to define the macromolecule baseline using FiTAID, a Fitting Tool for Arrays of Interrelated Datasets.

Authors:  Daniel G Q Chong; Roland Kreis; Christine S Bolliger; Chris Boesch; Johannes Slotboom
Journal:  MAGMA       Date:  2011-03-20       Impact factor: 2.310

2.  High-resolution in vivo diffusion imaging of the human brain with generalized slice dithered enhanced resolution: Simultaneous multislice (gSlider-SMS).

Authors:  Kawin Setsompop; Qiuyun Fan; Jason Stockmann; Berkin Bilgic; Susie Huang; Stephen F Cauley; Aapo Nummenmaa; Fuyixue Wang; Yogesh Rathi; Thomas Witzel; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2017-03-05       Impact factor: 4.668

Review 3.  Use of Multiplied, Added, Subtracted and/or FiTted Inversion Recovery (MASTIR) pulse sequences.

Authors:  Ya-Jun Ma; Shujuan Fan; Hongda Shao; Jiang Du; Nikolaus M Szeverenyi; Ian R Young; Graeme M Bydder
Journal:  Quant Imaging Med Surg       Date:  2020-06

4.  Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain.

Authors:  He Zhu; Craig K Jones; Peter C M van Zijl; Peter B Barker; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

5.  Whole-slice mapping of GABA and GABA+ at 7T via adiabatic MEGA-editing, real-time instability correction, and concentric circle readout.

Authors:  Philipp Moser; Lukas Hingerl; Bernhard Strasser; Michal Považan; Gilbert Hangel; Ovidiu C Andronesi; Andre van der Kouwe; Stephan Gruber; Siegfried Trattnig; Wolfgang Bogner
Journal:  Neuroimage       Date:  2018-09-19       Impact factor: 6.556

6.  ECLIPSE utilizing gradient-modulated offset-independent adiabaticity (GOIA) pulses for highly selective human brain proton MRSI.

Authors:  Chathura Kumaragamage; Henk M De Feyter; Peter Brown; Scott McIntyre; Terence W Nixon; Robin A de Graaf
Journal:  NMR Biomed       Date:  2020-10-01       Impact factor: 4.478

7.  Non-water-suppressed short-echo-time magnetic resonance spectroscopic imaging using a concentric ring k-space trajectory.

Authors:  Uzay E Emir; Brian Burns; Mark Chiew; Peter Jezzard; M Albert Thomas
Journal:  NMR Biomed       Date:  2017-03-08       Impact factor: 4.044

8.  Quantification of NAD+ in human brain with 1 H MR spectroscopy at 3 T: Comparison of three localization techniques with different handling of water magnetization.

Authors:  Martyna Dziadosz; Maike Hoefemann; André Döring; Malgorzata Marjańska; Edward John Auerbach; Roland Kreis
Journal:  Magn Reson Med       Date:  2022-05-08       Impact factor: 3.737

9.  Use of the 2D 1H-13C HSQC NMR Methyl Region to Evaluate the Higher Order Structural Integrity of Biopharmaceuticals.

Authors:  Tsang-Lin Hwang; Dipanwita Batabyal; Nicholas Knutson; Mats Wikström
Journal:  Molecules       Date:  2021-05-05       Impact factor: 4.411

10.  Simultaneous detection of metabolite concentration changes, water BOLD signal and pH changes during visual stimulation in the human brain at 9.4T.

Authors:  Johanna Dorst; Tamas Borbath; Karl Landheer; Nikolai Avdievich; Anke Henning
Journal:  J Cereb Blood Flow Metab       Date:  2022-01-21       Impact factor: 6.960

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.