Literature DB >> 10321826

Consensus report on quality control of quantitative measurements of renal function obtained from the renogram: International Consensus Committee from the Scientific Committee of Radionuclides in Nephrourology.

A Prigent1, P Cosgriff, G F Gates, G Granerus, E J Fine, K Itoh, M Peters, A Piepsz, M Rehling, M Rutland, A Taylor.   

Abstract

Among all the physiological indices that can be quantified using renography, measurement of renal function is the most basic. These measurements are used to make critical clinical management decisions and, as such, their reliability needs to be quality assured. This article seeks to address each aspect of the renography procedure, with particular emphasis on the effect on measurement of relative renal function. Estimation of individual kidney function is mentioned, but only briefly. A consensus approach was adopted, overseen, and directed by a chairman appointed by the Scientific Committee of the International Radionuclides in Nephro-Urology Group. The chairman selected the panel of experts from eight different countries based on their practical experience in the field. Where evidence exists to support the various recommendations it is given. Otherwise, the stated guidance represents the considered opinion of a body of experts, based on long experience and unpublished data. Some necessary compromises were made to account for the fact that renography is seldom performed solely with the purpose of measuring relative renal function. The technicalities of renography have always been a source of debate in nuclear medicine, which is reflected by the fact that a consensus could simply not be reached on a small number of issues. The structure of the report ensures that these are clearly indicated. This should serve to highlight gaps in our current knowledge, thus helping to direct future research. It is envisaged that the recommendations will be revised on a 2-year cycle to ensure that they remain up to date. An "open" process will be used to encourage participation and ownership. It is hoped that promotion of these guidelines, suitably complemented by audit processes, will raise standards in the practice of gamma camera renography.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10321826     DOI: 10.1016/s0001-2998(99)80005-1

Source DB:  PubMed          Journal:  Semin Nucl Med        ISSN: 0001-2998            Impact factor:   4.446


  39 in total

1.  Renal background correction and measurement of split renal function: The challenge : Editorial Comment: EJNM-D-15-00322, M Donald Blaufox, MD, PhD.

Authors:  M Donald Blaufox
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-03       Impact factor: 9.236

2.  A simple method for determining split renal function from dynamic (99m)Tc-MAG3 scintigraphic data.

Authors:  Michal J Wesolowski; Gary R Conrad; Martin Šámal; Gage Watson; Surajith N Wanasundara; Paul Babyn; Carl A Wesolowski
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-11-04       Impact factor: 9.236

3.  Development and prospective evaluation of an automated software system for quality control of quantitative 99mTc-MAG3 renal studies.

Authors:  Russell D Folks; Ernest V Garcia; Andrew T Taylor
Journal:  J Nucl Med Technol       Date:  2007-03

4.  SNMMI Procedure Standard/EANM Practice Guideline for Diuretic Renal Scintigraphy in Adults With Suspected Upper Urinary Tract Obstruction 1.0.

Authors:  Andrew T Taylor; David C Brandon; Diego de Palma; M Donald Blaufox; Emmanuel Durand; Belkis Erbas; Sandra F Grant; Andrew J W Hilson; Anni Morsing
Journal:  Semin Nucl Med       Date:  2018-03-16       Impact factor: 4.446

Review 5.  Measuring glomerular filtration rate in children; can cystatin C replace established methods? A review.

Authors:  Trine Borup Andersen; Anni Eskild-Jensen; Jørgen Frøkiaer; Jens Brøchner-Mortensen
Journal:  Pediatr Nephrol       Date:  2008-10-07       Impact factor: 3.714

6.  MR urography in children. Part 2: how to use ImageJ MR urography processing software.

Authors:  Pierre-Hugues Vivier; Michael Dolores; Melissa Taylor; Jean-Nicolas Dacher
Journal:  Pediatr Radiol       Date:  2010-02-25

7.  The SNMMI and EANM practice guideline for renal scintigraphy in adults.

Authors:  M Donald Blaufox; Diego De Palma; Andrew Taylor; Zsolt Szabo; Alain Prigent; Martin Samal; Yi Li; Andrea Santos; Giorgio Testanera; Mark Tulchinsky
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-08-30       Impact factor: 9.236

8.  At what level of unilateral renal impairment does contralateral functional compensation occur?

Authors:  Amy Piepsz; Alain Prigent; Michèle Hall; Khalid Ismaili; Frank Collier; Hamphrey Ham
Journal:  Pediatr Nephrol       Date:  2005-08-04       Impact factor: 3.714

9.  Optimizing scintigraphic evaluation of split renal function in living kidney donors using the geometric mean method: a preliminary retrospective study.

Authors:  Sarah Weinberger; Michael Baeder; Christian Scheurig-Muenkler; Ingo Guenter Steffen; Ahmed Magheli; Kurt Miller; Carsten Kempkensteffen
Journal:  J Nephrol       Date:  2015-08-19       Impact factor: 3.902

Review 10.  Radionuclides in nephrourology, part 1: Radiopharmaceuticals, quality control, and quantitative indices.

Authors:  Andrew T Taylor
Journal:  J Nucl Med       Date:  2014-02-18       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.