Literature DB >> 1031493

Differences between capillary and venous blood glucose during oral glucose tolerance tests.

U Larsson-Cohn.   

Abstract

The simultaneous capillary and venous blood glucose concentrations were measured during 36 oral glucose tolerance tests performed in 36 postmenopausal women. Three of the subjects had chemical diabetes mellitus. In samples obtained before and 120-180 min after the glucose load the differences between capillary and venous blood glucose concentrations were low, whereas samples taken after 15-90 min showed a mean capillary-venous difference of 1.8 mmol/l. This is higher than previously stated by the World Health Organization and the British Diabetes Association. If the definitions that were recommended by these two bodies are used for defining whether the result of an oral glucose tolerance test is to be considered 'normal' or 'abnormal', the present results indicate that the verdict will in some cases be influenced by the route by which the blood was obtained.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1031493     DOI: 10.3109/00365517609081941

Source DB:  PubMed          Journal:  Scand J Clin Lab Invest        ISSN: 0036-5513            Impact factor:   1.713


  9 in total

1.  Comparison of Accuracy Guidelines for Hospital Glucose Meters.

Authors:  Cynthia Foss Bowman; James H Nichols
Journal:  J Diabetes Sci Technol       Date:  2020-01-25

2.  Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus.

Authors:  David B Sacks; Mark Arnold; George L Bakris; David E Bruns; Andrea Rita Horvath; M Sue Kirkman; Ake Lernmark; Boyd E Metzger; David M Nathan
Journal:  Diabetes Care       Date:  2011-06       Impact factor: 19.112

3.  A Real-World Setting Study: Which Glucose Meter Could Be the Best for POCT Use? An Easy and Applicable Protocol During the Hospital Routine.

Authors:  Alessio Mancini; Giampaolo Esposto; Silvana Manfrini; Silvia Rilli; Gessica Tinti; Giuseppe Carta; Laura Petrolati; Matteo Vidali; Simone Barocci
Journal:  J Diabetes Sci Technol       Date:  2018-05-22

4.  Blood Glucose Measurement: Is Serum Equal to Plasma?

Authors:  Hye Soon Kim
Journal:  Diabetes Metab J       Date:  2016-10-12       Impact factor: 5.376

Review 5.  A1C versus glucose testing: a comparison.

Authors:  David B Sacks
Journal:  Diabetes Care       Date:  2011-02       Impact factor: 19.112

6.  Attenuation of postprandial blood glucose in humans consuming isomaltodextrin: carbohydrate loading studies.

Authors:  Tsuyoshi Sadakiyo; Yuki Ishida; Shin-Ichiro Inoue; Yoshifumi Taniguchi; Takeo Sakurai; Ryodai Takagaki; Mayumi Kurose; Tetsuya Mori; Akiko Yasuda-Yamashita; Hitoshi Mitsuzumi; Michio Kubota; Hikaru Watanabe; Shigeharu Fukuda
Journal:  Food Nutr Res       Date:  2017-05-24       Impact factor: 3.894

7.  Differences in circulating fatty acid-binding protein 4 concentration in the venous and capillary blood immediately after acute exercise.

Authors:  Shigeharu Numao; Ryota Uchida; Takashi Kurosaki; Masaki Nakagaichi
Journal:  J Physiol Anthropol       Date:  2021-02-10       Impact factor: 2.867

8.  Glucose absorption and gastric emptying in critical illness.

Authors:  Marianne J Chapman; Robert J L Fraser; Geoffrey Matthews; Antonietta Russo; Max Bellon; Laura K Besanko; Karen L Jones; Ross Butler; Barry Chatterton; Michael Horowitz
Journal:  Crit Care       Date:  2009-08-27       Impact factor: 9.097

9.  Postprandial capillary-venous glucose gradient in Type 1 diabetes: magnitude and clinical associations in a real world setting.

Authors:  I Lee; H Lunt; H Chan; H Heenan; J Berkeley; C M A Frampton
Journal:  Diabet Med       Date:  2015-12-24       Impact factor: 4.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.