Literature DB >> 10235577

Intraoperative scanning laser Doppler flowmetry in the assessment of gastric tube perfusion during esophageal resection.

N H Boyle1, A Pearce, D Hunter, W J Owen, R C Mason.   

Abstract

BACKGROUND: Ischemia from tissue hypoperfusion in the gastric tube after esophagectomy is believed to contribute significantly to postoperative complications associated with anastomotic failure. This study assessed the ability of the new technique of laser Doppler flowmetry to measure differential levels of blood flow in human gastric tubes during esophagectomy. STUDY
DESIGN: Gastric perfusion was measured in 16 patients undergoing esophagectomy by making laser Doppler scans of the stomach before mobilization and after formation of the gastric tube. Mean perfusion was calculated within the whole anterior surface of the stomach or tube and within 1 cm2 regions of interest, each of which contained 1,750 individual measurements of perfusion. These regions represented the cephalic end of the gastric tube, 10 adjacent 1 cm2 regions distally along the tube, and the proposed anastomosis site. Results were expressed as mean perfusion units, and tissue blood flow from each scan in each region was compared.
RESULTS: There were significant decreases in gastric perfusion measured with the scanning laser Doppler in all patients after formation of the gastric tube. Mean perfusion of the stomach fell 41% (p<0.0005) after mobilization. In all patients there was a gradient of perfusion from the proximal end of the tube where flow was poor, to more distal areas where it was higher. At the proximal end of the tube perfusion fell by a mean of 72%, 5 cm distally the mean fall was 44%, and 10 cm from the proximal end of the tube the mean fall was 28%. At the anastomosis site mean perfusion fell 55%.
CONCLUSIONS: This new technique can be used intraoperatively and appears to overcome the limitations of single point laser Doppler flowmetry. It has measured large differences in perfusion at different sites within the gastric tubes and could therefore have widespread clinical applications.

Entities:  

Mesh:

Year:  1999        PMID: 10235577     DOI: 10.1016/s1072-7515(99)00016-2

Source DB:  PubMed          Journal:  J Am Coll Surg        ISSN: 1072-7515            Impact factor:   6.113


  11 in total

Review 1.  The esophageal anastomosis: traditional methods to prevent leak.

Authors:  Daniel P Raymond
Journal:  J Gastrointest Surg       Date:  2009-05-05       Impact factor: 3.452

2.  Intraoperative thermal imaging in esophageal replacement: its use in the assessment of gastric tube viability.

Authors:  Katsunori Nishikawa; Hideki Matsudaira; Hideyuki Suzuki; Ryouji Mizuno; Nobuyoshi Hanyuu; Shuuichi Iwabuchi; Katsuhiko Yanaga
Journal:  Surg Today       Date:  2006       Impact factor: 2.549

3.  Vascular anatomy of the stomach related to resection procedures strategy.

Authors:  V Prudius; V Procházka; Z Pavlovský; D Prudius; Z Kala
Journal:  Surg Radiol Anat       Date:  2016-09-21       Impact factor: 1.246

4.  The safety and usefulness of endoscopy for evaluation of the graft and anastomosis early after esophagectomy and reconstruction.

Authors:  M S Maish; S R DeMeester; E Choustoulakis; J W Briel; J A Hagen; J H Peters; J C Lipham; C G Bremner; T R DeMeester
Journal:  Surg Endosc       Date:  2005-07-28       Impact factor: 4.584

5.  Experimental model of laparoscopic gastric ischemic preconditioning prior to transhiatal esophagectomy.

Authors:  Sandra M Jones Beck; Mary Beth Malay; Daniel J Gagné; Dennis L Fowler; Rodney J Landreneau
Journal:  Surg Endosc       Date:  2011-02-08       Impact factor: 4.584

6.  Safety and efficacy of hydroxyethyl starch 6% 130/0.4/9 solution versus 5% human serum albumin in thoracic esophagectomy with 3-field lymph nodes dissection.

Authors:  Takeo Fujita; Naoya Okada; Yasumasa Horikiri; Takuji Sato; Hisashi Fujiwara; Shuhei Mayanagi; Jun Kanamori; Hiroyuki Yamamoto; Hiroyuki Daiko
Journal:  Surg Today       Date:  2019-01-02       Impact factor: 2.549

7.  Mechanosensation and mucosal blood perfusion in the esophagus of healthy volunteers studied with a multimodal device incorporating laser Doppler flowmetry and endosonography.

Authors:  Dag Arne Lihaug Hoff; Hans Gregersen; Svein Odegaard; Donghua Liao; Jan Gunnar Hatlebakk
Journal:  Dig Dis Sci       Date:  2009-02-25       Impact factor: 3.199

8.  Fluorescent image-based evaluation of gastric conduit perfusion in a preclinical ischemia model.

Authors:  Yu Hua Quan; Minji Kim; Hyun Koo Kim; Beop-Min Kim
Journal:  J Thorac Dis       Date:  2018-09       Impact factor: 2.895

Review 9.  Gastric-tube versus whole-stomach esophagectomy for esophageal cancer: A systematic review and meta-analysis.

Authors:  Wenxiong Zhang; Dongliang Yu; Jinhua Peng; Jianjun Xu; Yiping Wei
Journal:  PLoS One       Date:  2017-03-07       Impact factor: 3.240

10.  Neovascularization after ischemic conditioning of the stomach and the influence of follow-up neoadjuvant chemotherapy thereon.

Authors:  Vadim Prudius; Vladimír Procházka; Zdeněk Pavlovský; Adam Peštál; Petr Vlček; Ivan Čapov; Lenka Veverková; Michal Reška
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2018-05-22       Impact factor: 1.195

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.