Literature DB >> 10234587

Does combining the results from multiple bone sites measured by a new quantitative ultrasound device improve discrimination of hip fracture?

D Hans1, S K Srivastav, C Singal, R Barkmann, C F Njeh, E Kantorovich, C C Glüer, H K Genant.   

Abstract

There is a growing interest in the use of quantitative ultrasound (QUS) measurements as an alternative to current radiation-based bone densitometry techniques for the noninvasive assessment of fracture risk. While most of the commercialized ultrasound devices measure only single predefined peripheral skeletal sites, the Omnisense prototype (Sunlight Ltd., Israel) can be used on multiple bones, including the spinous processes. In this study, we examined the ability of speed of sound measured at the calcaneus, distal third and ultradistal radius, proximal third phalanx, metacarpal, capitate, patella, and the posterior process of the thoracic spine to differentiate subjects with hip fractures from normal controls. Seventy-nine postmenopausal Caucasian Israeli women who had sustained an atraumatic fracture of the proximal femur within the last 6 months were recruited from the local population (mean age 80 +/- 8.9 years). As controls, 295 postmenopausal Caucasian Israeli women without osteoporotic fractures were also included (mean age 70 +/- 8.7 years). Discrimination of hip fractures with QUS at all ultrasound sites was highly statistically significant (p < 0.01) (odds ratios [ORs] = 1.4-3.0; area under the ROC curve [AUC] 77-92%), except for the hand metacarpal. Distal radius and calcaneus measurements (ORs = 2.4 and 3.0) were the best discriminators of hip fracture patients from controls. Using a forward selective linear regression model, the discriminator values of combined assessment at two sites were investigated. There was moderate improvement in diagnostic value, but the best combination was the calcaneus with the distal radius, which improved the AUC by 3% and raised both the sensitivity and specificity to 94%. These data demonstrate the encouraging potential of improving discrimination of hip fracture by using multiple-site ultrasonic measurements.

Entities:  

Keywords:  Non-programmatic

Mesh:

Year:  1999        PMID: 10234587     DOI: 10.1359/jbmr.1999.14.4.644

Source DB:  PubMed          Journal:  J Bone Miner Res        ISSN: 0884-0431            Impact factor:   6.741


  28 in total

1.  Soy milk and dairy consumption is independently associated with ultrasound attenuation of the heel bone among postmenopausal women: the Adventist Health Study-2.

Authors:  Vichuda Lousuebsakul Matthews; Synnove F Knutsen; W Lawrence Beeson; Gary E Fraser
Journal:  Nutr Res       Date:  2011-10       Impact factor: 3.315

2.  Can geometry-based parameters from pQCT and material parameters from quantitative ultrasound (QUS) improve the prediction of radial bone strength over that by bone mass (DXA)?

Authors:  M Hudelmaier; V Kuhn; E M Lochmüller; H Well; M Priemel; T M Link; F Eckstein
Journal:  Osteoporos Int       Date:  2004-01-22       Impact factor: 4.507

3.  Autocorrelation and cepstral methods for measurement of tibial cortical thickness.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-06       Impact factor: 2.725

4.  Bone mineral density-independent association of quantitative ultrasound measurements and fracture risk in women.

Authors:  Tuan V Nguyen; Jacqueline R Center; John A Eisman
Journal:  Osteoporos Int       Date:  2004-08-07       Impact factor: 4.507

Review 5.  [Quantitative ultrasound].

Authors:  R Barkmann; C-C Glüer
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

6.  Longitudinal monitoring of bone accretion measured by quantitative multi-site ultrasound (QUS) of bones in patients with delayed puberty (a pilot study).

Authors:  Zvi Zadik; Tali Sinai; Ella Borondukov; Amnon Zung; Irit Yaniv; Ram Reifen
Journal:  Osteoporos Int       Date:  2004-12-23       Impact factor: 4.507

7.  Good maintenance of physical benefits in a 12-month exercise and nutritional intervention by voluntary, home-based exercise: a 6-month follow-up of a randomized controlled trial.

Authors:  Zhen-Bo Cao; Izumi Tabata; Hidetsugu Nishizono
Journal:  J Bone Miner Metab       Date:  2009-01-27       Impact factor: 2.626

8.  Multi-site quantitative ultrasound compared to dual energy X-ray absorptiometry in rheumatoid arthritis: effects of body mass index and inflamed soft tissue on reproducibility.

Authors:  A Pfeil; J Böttcher; H J Mentzel; G Lehmann; M L Schäfer; A Kramer; A Petrovitch; B E Seidl; A Malich; G Hein; G Wolf; W A Kaiser
Journal:  Rheumatol Int       Date:  2006-05-31       Impact factor: 2.631

9.  Predicting the failure load of the distal radius.

Authors:  Monique E Muller; Colin E Webber; Mary L Bouxsein
Journal:  Osteoporos Int       Date:  2003-04-25       Impact factor: 4.507

10.  Bone status in rheumatoid arthritis assessed at peripheral sites by three different quantitative ultrasound devices.

Authors:  O R Madsen; C Suetta; C Egsmose; J S Lorentzen; O H Sørensen
Journal:  Clin Rheumatol       Date:  2004-05-18       Impact factor: 2.980

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.