Literature DB >> 26676685

Hemodynamic impact of abdominal aortic aneurysm stent-graft implantation-induced stenosis.

Nicolas Aristokleous1, Nikolaos G Kontopodis2, Konstantinos Tzirakis1, Christos V Ioannou2, Yannis Papaharilaou3.   

Abstract

The current study aims to computationally evaluate the hemodynamic impact of a novel sealing mechanism employed by a recently developed endograft (Ovation TriVascular Stent-Graft System) for endovascular aneurysm repair. The exploitation of two inflatable O-rings to achieve sealing may be advantageous in terms of accommodating challenging anatomies, but comes at a price of a marked inflow stenosis. Here, four representative patient cases of inflow stenosis ranging from 30 to 80 % were analyzed. Lumen surface models were constructed from 1 month post-operative computed tomography images and then used to numerically compute the complex endograft flow field. Our results highlight coexistence of stenotic wall regions exposed to high shear rate and post-stenotic recirculation zones. These conditions may implicate platelet activation and predispose thrombus formation and thromboembolic complications. A clinically insignificant cycle-averaged pressure drop along the inflow stenosis and further in the endograft main body legs was predicted (range 0.01-1.72 mmHg) which was, however, notable at peak systole (range 3.52-19.73 mmHg). Although the functional impact of the endograft stenosis at rest flow conditions may appear insignificant, increased flow rate during exercise is expected to strongly accentuate the observed effects. Pressure drop in the endograft legs was attributed to suboptimal, based on Murray's scaling law, cross-sectional area ratio between trunk and legs of the device.

Entities:  

Keywords:  Abdominal aortic aneurysm; Endovascular graft; Image-based CFD; Thrombosis

Mesh:

Year:  2015        PMID: 26676685     DOI: 10.1007/s11517-015-1425-1

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  38 in total

Review 1.  A meta-analysis of 50 years of ruptured abdominal aortic aneurysm repair.

Authors:  M J Bown; A J Sutton; P R F Bell; R D Sayers
Journal:  Br J Surg       Date:  2002-06       Impact factor: 6.939

Review 2.  Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery.

Authors:  F L Moll; J T Powell; G Fraedrich; F Verzini; S Haulon; M Waltham; J A van Herwaarden; P J E Holt; J W van Keulen; B Rantner; F J V Schlösser; F Setacci; J-B Ricco
Journal:  Eur J Vasc Endovasc Surg       Date:  2011-01       Impact factor: 7.069

Review 3.  Pathophysiology and epidemiology of abdominal aortic aneurysms.

Authors:  Ian M Nordon; Robert J Hinchliffe; Ian M Loftus; Matt M Thompson
Journal:  Nat Rev Cardiol       Date:  2010-11-16       Impact factor: 32.419

4.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

5.  Shear-induced platelet activation and platelet microparticle formation at blood flow conditions as in arteries with a severe stenosis.

Authors:  P A Holme; U Orvim; M J Hamers; N O Solum; F R Brosstad; R M Barstad; K S Sakariassen
Journal:  Arterioscler Thromb Vasc Biol       Date:  1997-04       Impact factor: 8.311

6.  Outflow conditions for image-based hemodynamic models of the carotid bifurcation: implications for indicators of abnormal flow.

Authors:  Umberto Morbiducci; Diego Gallo; Diana Massai; Filippo Consolo; Raffaele Ponzini; Luca Antiga; Cristina Bignardi; Marco A Deriu; Alberto Redaelli
Journal:  J Biomech Eng       Date:  2010-09       Impact factor: 2.097

7.  A decoupled fluid structure approach for estimating wall stress in abdominal aortic aneurysms.

Authors:  Yannis Papaharilaou; John A Ekaterinaris; Eirini Manousaki; Asterios N Katsamouris
Journal:  J Biomech       Date:  2006-02-28       Impact factor: 2.712

8.  Resident and fellow experiences after the introduction of endovascular aneurysm repair for abdominal aortic aneurysm.

Authors:  Teviah Sachs; Marc Schermerhorn; Frank Pomposelli; Philip Cotterill; James O'Malley; Bruce Landon
Journal:  J Vasc Surg       Date:  2011-05-28       Impact factor: 4.268

9.  Patient-specific computational fluid dynamics: structured mesh generation from coronary angiography.

Authors:  Gianluca De Santis; Peter Mortier; Matthieu De Beule; Patrick Segers; Pascal Verdonck; Benedict Verhegghe
Journal:  Med Biol Eng Comput       Date:  2010-02-17       Impact factor: 2.602

10.  Computational fluid dynamics within bifurcated abdominal aortic stent-grafts.

Authors:  Benjamin A Howell; Tom Kim; Angela Cheer; Harry Dwyer; David Saloner; Timothy A M Chuter
Journal:  J Endovasc Ther       Date:  2007-04       Impact factor: 3.487

View more
  5 in total

1.  Coupling of shear-circumferential stress pulses investigation through stress phase angle in FSI models of stenotic artery using experimental data.

Authors:  Milad Samaee; Mohammad Tafazzoli-Shadpour; Hamed Alavi
Journal:  Med Biol Eng Comput       Date:  2016-10-05       Impact factor: 2.602

2.  Occlusive Shrinkage of Ovation Endograft Presenting as Acute Lower Limb Ischemia: Effective Endovascular Management.

Authors:  Paolo Bianchi; Filippo Scalise; Andrea Mortara; Guido Lanzillo; Giuseppe Scardina; Santi Trimarchi; Gianfranco Parati; Valerio Tolva
Journal:  Aorta (Stamford)       Date:  2017-02-01

3.  Synchrotron radiation computed tomography versus conventional computed tomography for assessment of four types of stent grafts used for endovascular treatment of thoracic and abdominal aortic aneurysms.

Authors:  Zhonghua Sun; Curtise K C Ng; Cláudia Sá Dos Reis
Journal:  Quant Imaging Med Surg       Date:  2018-07

4.  Patient-Specific, Multi-Scale Modeling of Neointimal Hyperplasia in Vein Grafts.

Authors:  Francesca Donadoni; Cesar Pichardo-Almarza; Matthew Bartlett; Alan Dardik; Shervanthi Homer-Vanniasinkam; Vanessa Díaz-Zuccarini
Journal:  Front Physiol       Date:  2017-04-18       Impact factor: 4.566

5.  A Lagrangian cylindrical coordinate system for characterizing dynamic surface geometry of tubular anatomic structures.

Authors:  Torbjörn Lundh; Ga-Young Suh; Phillip DiGiacomo; Christopher Cheng
Journal:  Med Biol Eng Comput       Date:  2018-03-03       Impact factor: 2.602

  5 in total