Literature DB >> 10214796

Clinical results of the CLARION magnetless cochlear implant.

B P Weber1, J Neuburger, J E Goldring, T Santogrossi, H Koestler, R D Battmer, T Lenarz.   

Abstract

This paper reports initial results for the CLARION Multi-Strategy Cochlear Implant, presently under investigational study in Europe. A magnetless implantable cochlear stimulator (ICS) with an ear-mold-supported headpiece was designed in response to an increasing demand for a magnetic resonance imaging (MRI)-compatible cochlear implant. Surgical technique, accompanying magnetless headpiece, and MRI compatibility were evaluated in 11 deaf patients (ages 6 to 62 years) who were implanted with a magnetless Clarion implant. Because of the headset mechanics, the ICS was implanted closer behind the ear than a magnet-containing ICS. The ICS-MRI compatibility was investigated with 1.5- and 0.3-T MRI. Results showed that the surgery was relatively safe and easy to learn. The headset was stable and reliable. The MRI compatibility tests indicate that the ICS poses no contraindication for patients needing MRI. Overall, the results suggest that the Clarion magnetless cochlear implant is relatively safe and easy to implant, is MRI-compatible, and functions well with the ear-mold-supported headpiece.

Entities:  

Mesh:

Year:  1999        PMID: 10214796     DOI: 10.1177/00034894991080s405

Source DB:  PubMed          Journal:  Ann Otol Rhinol Laryngol Suppl        ISSN: 0096-8056


  4 in total

1.  Artifacts caused by cochlear implants with non-removable magnets in 3T MRI: phantom and cadaveric studies.

Authors:  Omid Majdani; Thomas S Rau; Friedrich Götz; Martin Zimmerling; Minoo Lenarz; Thomas Lenarz; Robert Labadie; Martin Leinung
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-07-23       Impact factor: 2.503

2.  Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

Authors:  F Dubrulle; A Sufana Iancu; C Vincent; G Tourrel; O Ernst
Journal:  Eur Radiol       Date:  2013-01-10       Impact factor: 5.315

Review 3.  [Magnetic resonance imaging in patients with magnetic hearing implants: overview and procedural management].

Authors:  S Nospes; W Mann; A Keilmann
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

4.  Significant Artifact Reduction at 1.5T and 3T MRI by the Use of a Cochlear Implant with Removable Magnet: An Experimental Human Cadaver Study.

Authors:  Franca Wagner; Wilhelm Wimmer; Lars Leidolt; Mattheus Vischer; Stefan Weder; Roland Wiest; Georgios Mantokoudis; Marco D Caversaccio
Journal:  PLoS One       Date:  2015-07-22       Impact factor: 3.240