Literature DB >> 10206255

Superior gluteal artery injury during iliosacral screw placement.

D T Altman1, C B Jones, M L Routt.   

Abstract

Percutaneous fixation of an unstable pelvic ring injury is becoming a popular method of pelvic stabilization. As posterior pelvic percutaneous techniques become more common, the possibility of iatrogenic complications increases. This case report describes an injury to the superior gluteal artery during percutaneous iliosacral screw insertion and the treatment of this potentially devastating injury.

Entities:  

Mesh:

Year:  1999        PMID: 10206255     DOI: 10.1097/00005131-199903000-00011

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  23 in total

1.  [The minimally invasive stabilization of the dorsal pelvic ring with the transiliacal internal fixator (TIFI)--surgical technique and first clinical findings].

Authors:  B Füchtmeier; M Maghsudi; C Neumann; R Hente; C Roll; M Nerlich
Journal:  Unfallchirurg       Date:  2004-12       Impact factor: 1.000

2.  Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.

Authors:  Jörn Zwingmann; Gerhard Konrad; Elmar Kotter; Norbert P Südkamp; Michael Oberst
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

Review 3.  Robotic versus freehand S2 alar iliac fixation: in-depth technical considerations.

Authors:  Joseph L Laratta; Jamal N Shillingford; Joshua S Meredith; Lawrence G Lenke; Ronald A Lehman; Jeffrey L Gum
Journal:  J Spine Surg       Date:  2018-09

4.  [3D image enhancer-adjusted percutaneous triangular stabilization of geriatric pelvic ring fractures : Operation technique and indications].

Authors:  Matthias Spalteholz; Jens Gulow
Journal:  Unfallchirurg       Date:  2019-11       Impact factor: 1.000

5.  Anatomical and CT angiographic study of superior gluteal neurovascular pedicle: implications for hip surgery.

Authors:  Carla Stecco; Veronica Macchi; Luca Baggio; Andrea Porzionato; A Berizzi; Roberto Aldegheri; Raffaele De Caro
Journal:  Surg Radiol Anat       Date:  2012-09-16       Impact factor: 1.246

6.  A minimally invasive stabilizing system for dorsal pelvic ring injuries.

Authors:  Thomas Dienstknecht; Arne Berner; Andreas Lenich; Michael Nerlich; Bernd Fuechtmeier
Journal:  Clin Orthop Relat Res       Date:  2011-05-24       Impact factor: 4.176

Review 7.  [Pelvic ring fractures in the elderly. Underestimated osteoporotic fracture].

Authors:  T Fuchs; U Rottbeck; V Hofbauer; M Raschke; R Stange
Journal:  Unfallchirurg       Date:  2011-08       Impact factor: 1.000

8.  Technical and clinical outcome of percutaneous CT fluoroscopy-guided screw placement in unstable injuries of the posterior pelvic ring.

Authors:  Frederik F Strobl; Sophia M Haeussler; Philipp M Paprottka; Ralf-Thorsten Hoffmann; Oliver Pieske; Maximilian F Reiser; Christoph G Trumm
Journal:  Skeletal Radiol       Date:  2014-05-10       Impact factor: 2.199

9.  2D-fluoroscopic navigated percutaneous screw fixation of pelvic ring injuries--a case series.

Authors:  Florian Gras; Ivan Marintschev; Arne Wilharm; Kajetan Klos; Thomas Mückley; Gunther O Hofmann
Journal:  BMC Musculoskelet Disord       Date:  2010-07-07       Impact factor: 2.362

Review 10.  2D versus 3D fluoroscopy-based navigation in posterior pelvic fixation: review of the literature on current technology.

Authors:  Savyasachi C Thakkar; Rashmi S Thakkar; Norachart Sirisreetreerux; John A Carrino; Babar Shafiq; Erik A Hasenboehler
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-08-08       Impact factor: 2.924

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.