A minimally invasive stabilizing system for dorsal pelvic ring injuries.

Thomas Dienstknecht1, Arne Berner, Andreas Lenich, Michael Nerlich, Bernd Fuechtmeier.   

Abstract

BACKGROUND: Open reduction and stabilization of dorsal pelvic ring injuries is accompanied by a high rate of soft tissue complications. Minimally invasive techniques have the potential to decrease soft tissue trauma, but the risk of iatrogenic nerve and vessel damage through the reduced surgical exposure should be considered. We treated these injuries using a transiliac internal fixator (TIFI) in a minimally invasive technique characterized by implantation of a pedicle screw and rod system, bridging the sacroiliac joints and the sacral area. QUESTIONS/PURPOSES: We asked whether (1) we could achieve anatomic restoration with the device, (2) specific complications were associated with this minimally invasive approach (particularly enhanced intraoperative blood loss, soft tissue complications, and iatrogenic neurovascular damage), and (3) function 3 years after trauma was comparable to that of established methods.
METHODS: We retrospectively reviewed 67 patients with dorsal pelvic injuries during a 7-year period. We evaluated the (1) reduction by grading the maximal displacement measured with three radiographic views, (2) the complications during the observation period, and (3) the function with a validated questionnaire (Pelvic Outcome Score) in all but five patients at least 3 years after trauma (mean, 37 months; range, 36-42 months).
RESULTS: At last followup we observed a secondary fracture displacement greater than 5 mm in one patient. The intraoperative blood loss was less than 50 mL in all patients. No neurovascular lesions occurred owing to implantation. Four patients had wound infections, one had loosening of a single pedicle screw, and one had an iatrogenic screw malpositioning. Thirty-five of the 62 patients achieved Pelvic Outcome Scores of either a maximum score or 6 of 7 points.
CONCLUSION: Our observations suggest TIFI is a reasonable alternative to other established fixation devices for injuries of the dorsal pelvic ring with minor risks of major blood loss or iatrogenic neurovascular damage. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2011        PMID: 21607750      PMCID: PMC3183204          DOI: 10.1007/s11999-011-1922-y

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  39 in total

1.  Anatomically correct reduction and fixation of a Tile C-1 type unilateral sacroiliac disruption using a rod and pedicle screw system between the S1 vertebra and the ilium: experimental and clinical case report.

Authors:  Kunio Saiki; Shigeru Hirabayashi; Toshihiro Horie; Nobuyuki Tsuzuki; Kouichi Inokuchi; Haruhiko Tsutsumi
Journal:  J Orthop Sci       Date:  2002       Impact factor: 1.601

Review 2.  Stabilization of pelvic ring disruptions.

Authors:  M L Routt; P T Simonian; M F Swiontkowski
Journal:  Orthop Clin North Am       Date:  1997-07       Impact factor: 2.472

3.  Outcome of operatively treated unstable posterior pelvic ring disruptions.

Authors:  P Tornetta; J M Matta
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

4.  [Complex pelvic trauma in elderly patients].

Authors:  G Tosounidis; U Culemann; D Stengel; P Garcia; R Kurowski; J H Holstein; T Pohlemann
Journal:  Unfallchirurg       Date:  2010-04       Impact factor: 1.000

5.  Acute Pelvic Fractures: II. Principles of Management.

Authors: 
Journal:  J Am Acad Orthop Surg       Date:  1996-05       Impact factor: 3.020

6.  Outcome of operatively treated type-C injuries of the pelvic ring.

Authors:  Jan Lindahl; Eero Hirvensalo
Journal:  Acta Orthop       Date:  2005-10       Impact factor: 3.717

7.  Vertical shear injuries: is there a relationship between residual displacement and functional outcome?

Authors:  J V Nepola; S W Trenhaile; M A Miranda; S L Butterfield; D C Fredericks; B L Riemer
Journal:  J Trauma       Date:  1999-06

Review 8.  High-energy pelvic ring disruptions.

Authors:  M L Chip Routt; Sean E Nork; William J Mills
Journal:  Orthop Clin North Am       Date:  2002-01       Impact factor: 2.472

9.  Biomechanical testing of new and old fixation devices for vertical shear fractures of the pelvis.

Authors:  R K Leighton; J P Waddell; T J Bray; M W hapman; L Simpson; R B Martin; N A Sharkey
Journal:  J Orthop Trauma       Date:  1991       Impact factor: 2.512

10.  Early open reduction and internal fixation of the disrupted pelvic ring.

Authors:  A Goldstein; T Phillips; S J Sclafani; T Scalea; A Duncan; J Goldstein; T Panetta; G Shaftan
Journal:  J Trauma       Date:  1986-04
View more
  15 in total

1.  The anterior subcutaneous internal fixator (ASIF) for unstable pelvic ring fractures: clinical and radiological mid-term results.

Authors:  Franz Josef Müller; Wolfgang Stosiek; Michael Zellner; Rainer Neugebauer; Bernd Füchtmeier
Journal:  Int Orthop       Date:  2013-08-31       Impact factor: 3.075

2.  Midterm radiologic and functional outcomes of minimally-invasive fixation of unstable pelvic fractures using anterior internal fixator(INFIX) and percutaneous iliosacral screws.

Authors:  Ajoy Prasad Shetty; Aju Bosco; Ramesh Perumal; Jeyaramaraju Dheenadhayalan; Shanmuganathan Rajasekaran
Journal:  J Clin Orthop Trauma       Date:  2017-06-10

3.  Surgical technique: a percutaneous method of subcutaneous fixation for the anterior pelvic ring: the pelvic bridge.

Authors:  Timothy G Hiesterman; Brian W Hill; Peter A Cole
Journal:  Clin Orthop Relat Res       Date:  2012-08       Impact factor: 4.176

Review 4.  [Cement augmentation in pelvic ring fractures].

Authors:  Andreas E Ellmerer; Markus A Küper; Mika F Rollmann; Steven C Herath; Tina Histing
Journal:  Unfallchirurgie (Heidelb)       Date:  2022-05-23

5.  Surgical management of osteoporotic pelvic fractures: a new challenge.

Authors:  P M Rommens; D Wagner; A Hofmann
Journal:  Eur J Trauma Emerg Surg       Date:  2012-09-23       Impact factor: 3.693

6.  Patient-related outcome of unstable pelvic ring fractures stabilized with a minimal invasive screw-rod system.

Authors:  Maximilian Kerschbaum; Nadine Hausmann; Michael Worlicek; Christian Pfeifer; Michael Nerlich; Paul Schmitz
Journal:  Health Qual Life Outcomes       Date:  2017-12-22       Impact factor: 3.186

7.  Minimally invasive treatment of unstable pelvic ring injuries with modified pedicle screw-rod fixator.

Authors:  Xiao-Tian Wu; Zuo-Qing Liu; Wen-Qin Fu; Shan Zhao
Journal:  J Int Med Res       Date:  2017-06-29       Impact factor: 1.671

Review 8.  Patient Weight-bearing after Pelvic Fracture Surgery-A Systematic Review of the Literature: What is the Modern Evidence Base?

Authors:  Mark Rickman; Bjorn-Christian Link; Lucian B Solomon
Journal:  Strategies Trauma Limb Reconstr       Date:  2019 Jan-Apr

9.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

10.  Iliac intramedullary stabilization for Type IIIA fragility fractures of the pelvis.

Authors:  Shingo Okazaki; Masahiro Shirahama; Ryuki Hashida; Mitsuhiro Matsuura; Shiro Yoshida; Kenjiro Nakama; Hiroo Matsuse; Naoto Shiba
Journal:  Sci Rep       Date:  2020-11-23       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.