Literature DB >> 10194015

Feasibility of partial A2 and A4 pulley excision: effect on finger flexor tendon biomechanics.

G Mitsionis1, J A Bastidas, R Grewal, H J Pfaeffle, K J Fischer, M M Tomaino.   

Abstract

We investigated the effect of partial excision of the A2 and A4 digital pulleys, separately and in combination, on finger angular rotation and the energy for finger flexion. Statistically significant decreases in angular rotation resulted only after 50% and 75% excision of A2, A4, or A2 and A4 in combination. Work of flexion trends were weak and none of the changes were statistically significant. Although optimal finger function relies on the integrity of the A2 and A4 pulleys to maintain the efficiency of the digital flexor system, these data suggest that the A2 and A4 pulleys can be excised up to 25%, either separately or in combination, without significant effects on angular rotation. Decreases in total angular range of motion after 50% and 75% pulley excision were small, even for combined pulley excision (9 degrees +/- 3 degrees and 15 degrees +/- 5 degrees [mean +/- SD], respectively), and may be clinically acceptable.

Entities:  

Mesh:

Year:  1999        PMID: 10194015     DOI: 10.1053/jhsu.1999.0310

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  11 in total

Review 1.  [Tenolysis of the flexor tendons in the hand].

Authors:  T Pillukat; R Fuhrmann; J Windolf; J van Schoonhoven
Journal:  Orthopade       Date:  2015-10       Impact factor: 1.087

2.  The Relationship Between the Intercrease Line and the A1 Digital Pulley: A Cadaveric Study.

Authors:  Colyn J Watkins; Nikola Zivaljevic; Kyle R Eberlin; Michael Rivlin; Chaitanya S Mudgal
Journal:  Hand (N Y)       Date:  2016-07-28

3.  Moment arms of the human digital flexors.

Authors:  Orrin I Franko; Taylor M Winters; Timothy F Tirrell; Eric R Hentzen; Richard L Lieber
Journal:  J Biomech       Date:  2011-05-10       Impact factor: 2.712

4.  Importance of proximal A2 and A4 pulleys to maintaining kinematics in the hand: a biomechanical study.

Authors:  James C Chow; Jon Sensinger; David McNeal; Bettina Chow; Farid Amirouche; Mark Gonzalez
Journal:  Hand (N Y)       Date:  2014-03

5.  The Effect of Pulley Reconstruction on Maximum Flexion, Bowstringing, and Gliding Coefficient in the Setting of Zone II Repair of FDS and FDP: a Cadaveric Investigation.

Authors:  Spencer J Stanbury; Christopher English; Zaneb Yaseen; Jeffrey D Reed; Tony Chen; Hani Awad; John C Elfar
Journal:  Hand (N Y)       Date:  2014-03

Review 6.  [Tenoarthrolysis after flexor tendon injuries].

Authors:  Thomas Pillukat; Joachim Windolf; Jörg van Schoonhoven
Journal:  Unfallchirurg       Date:  2020-02       Impact factor: 1.000

7.  Quantification of partial or complete A4 pulley release with FDP repair in cadaveric tendons.

Authors:  Orrin I Franko; Nathan M Lee; John J Finneran; Matthew C Shillito; Matthew J Meunier; Reid A Abrams; Richard L Lieber
Journal:  J Hand Surg Am       Date:  2011-03       Impact factor: 2.230

Review 8.  Closed flexor pulley injuries: A literature review and current practice.

Authors:  Francesco Bosco; Fortunato Giustra; Alessandro Lusso; Carlotta Faccenda; Stefano Artiaco; Alessandro Massè
Journal:  J Orthop       Date:  2022-09-09

9.  Modeling of multiarticular muscles: importance of inclusion of tendon-pulley interactions in the finger.

Authors:  Sang Wook Lee; Derek G Kamper
Journal:  IEEE Trans Biomed Eng       Date:  2009-04-07       Impact factor: 4.538

Review 10.  Avoidance of unfavourable results following primary flexor tendon surgery.

Authors:  D Elliot; T Giesen
Journal:  Indian J Plast Surg       Date:  2013-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.