Perception of temporally filtered X-ray fluoroscopy images.

D L Wilson1, K N Jabri, R Aufrichtig.   

Abstract

For noisy X-ray fluoroscopy image sequences we quantitatively evaluated image quality after digital temporal filtering to reduce noise. Using an experimental paradigm called a reference/test adaptive forced-choice method we compared detectability of stationary low-contrast disks in filtered and unfiltered, computer-generated image sequences. In the first experiment, a low-pass first-order recursive filter used in X-ray fluoroscopy was found to be much less effective at enhancing detectability than predicted from the reduction of display noise variance, a common measurement of filter effectiveness. Detectability was reasonably predicted by a nonprewhitening human-observer model (NPW-HVS) that included an independently determined human temporal-contrast-sensitivity function. In another experiment, designed to test models over a range of temporal frequencies, we used paired high-pass and low-pass temporal filters that both reduced noise variance by 25%. The high-pass filter was artificially applied to the noise only and greatly improved detectability, while the low-pass filter had little effect. The human-observer model quantitatively described the measurements, but classical prewhitening and nonprewhitening signal detectors did not. As compared to the nonprewhitening, spatio-temporal matched filter, human-observer efficiency was low and variable at 2.1%, 2.9%, and 0.06% for 60 frames of unfiltered low-pass and high-pass noise, respectively. As compared to this detector, humans were not very effective at combining information across frames. On the other hand, signal to noise ratios (SNR's) from the human-observer model were comparable to human performance, and efficiencies were reasonably constant at 40%, 52%, and 32%, respectively. We conclude that it is imperative to include human-observer models and experiments in the analysis of noise-reduction filtering of noisy image sequences, such as X-ray fluoroscopy.

Entities:  

Mesh:

Year:  1999        PMID: 10193694     DOI: 10.1109/42.750250

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  6 in total

1.  An algorithm for tracking microcatheters in fluoroscopy.

Authors:  Akihiro Takemura; Kenneth R Hoffmann; Masayuki Suzuki; Zhou Wang; Hussain S Rangwala; Hajime Harauchi; Stephen Rudin; Tokuo Umeda
Journal:  J Digit Imaging       Date:  2008-03       Impact factor: 4.056

2.  Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems.

Authors:  Christopher P Favazza; Kenneth A Fetterly; Nicholas J Hangiandreou; Shuai Leng; Beth A Schueler
Journal:  J Med Imaging (Bellingham)       Date:  2015-03-25

3.  Overcoming x-ray tube small focal spot output limitations for high-resolution region of interest imaging.

Authors:  Sandesh K Gupta; Amit Jain; Daniel R Bednarek; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-08

4.  Task-based evaluation of a 4D MAP-RBI-EM image reconstruction method for gated myocardial perfusion SPECT using a human observer study.

Authors:  Taek-Soo Lee; Takahiro Higuchi; Riikka Lautamäki; Frank M Bengel; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2015-08-24       Impact factor: 3.609

5.  A motion-compensated image filter for low-dose fluoroscopy in a real-time tumor-tracking radiotherapy system.

Authors:  Naoki Miyamoto; Masayori Ishikawa; Kenneth Sutherland; Ryusuke Suzuki; Taeko Matsuura; Chie Toramatsu; Seishin Takao; Hideaki Nihongi; Shinichi Shimizu; Kikuo Umegaki; Hiroki Shirato
Journal:  J Radiat Res       Date:  2014-08-16       Impact factor: 2.724

6.  Real-time X-ray imaging of mouse cerebral microvessels in vivo using a pixel temporal averaging method.

Authors:  Fucheng Yu; Feixiang Wang; Ke Li; Guohao Du; Biao Deng; Honglan Xie; Guoyuan Yang; Tiqiao Xiao
Journal:  J Synchrotron Radiat       Date:  2022-01-01       Impact factor: 2.616

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.