Literature DB >> 10192014

Intraoperative limb length measurement in total hip arthroplasty.

M Naito1, K Ogata, I Asayama.   

Abstract

In order to evaluate the efficacy of intraoperative measurement of limb length inequality (LLI), we performed a prospective study on 64 patients who underwent unilateral total hip arthroplasty. The patients were divided into 2 groups. In Group I, the LLI was evaluated by the Shuck test, and in Group II by intraoperative measurement using a Steinman pin and an adjustable caliper. Preoperative LLIs assessed on radiographs averaged 1.18 cm in Group I and 0.37 cm in Group II.

Entities:  

Mesh:

Year:  1999        PMID: 10192014      PMCID: PMC3619784          DOI: 10.1007/s002640050298

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  9 in total

1.  Leg length discrepancy after total hip arthroplasty: a review of literature.

Authors:  Aravind S Desai; Asterios Dramis; Tim N Board
Journal:  Curr Rev Musculoskelet Med       Date:  2013-12

2.  Accuracy of the Horizontal Calibrator in Correcting Leg Length and Restoring Femoral Offset in Total Hip Arthroplasty.

Authors:  Xing Chen; Shuxing Xing; Zhiyong Zhu; Huisheng Wang; Zhongshen Yu; Xizhuang Bai; Xi Li
Journal:  Front Surg       Date:  2022-03-03

3.  Accuracy of the relationship between the centre of the femoral head and tip of greater trochanter.

Authors:  Baljinder S Dhinsa; Aaron Saini; Alastair G Dick; William J Nash; Obinna Nzeako; Zameer Shah
Journal:  J Clin Orthop Trauma       Date:  2018-08-24

4.  Restoration of femoral offset, rotation centers, limbs length equality of Chinese total hip arthroplasty patients.

Authors:  Yu-Ping Liu; Yue-Dong Hao
Journal:  Pak J Med Sci       Date:  2014-01       Impact factor: 1.088

5.  Intraoperative measurement of limb lengthening during total hip arthroplasty.

Authors:  Dimitrios Vasileiou Papadopoulos; Panagiotis Koulouvaris; Georgios Charalambos Aggelidakis; Andreas Georgios Tsantes; Marios Georgios Lykissas; Alexandros Mavrodontidis
Journal:  Indian J Orthop       Date:  2017 Mar-Apr       Impact factor: 1.251

6.  Double-Stitch Technique: A Simple and Effective Method to Minimize Limb Length Discrepancy after Total Hip Arthroplasty.

Authors:  Rakesh Gupta; Pradeep Pathak; Raj Singh; Krishna P Majumdar
Journal:  Indian J Orthop       Date:  2019 Jan-Feb       Impact factor: 1.251

7.  Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study.

Authors:  Hiromasa Tanino; Yasuhiro Nishida; Ryo Mitsutake; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2021-03-23       Impact factor: 2.362

8.  An intraoperative device to restore femoral offset in total hip arthroplasty.

Authors:  Enxing Xue; Zhen Su; Chengwang Chen; Paul Kim Chiu Wong; Hong Wen; Yu Zhang
Journal:  J Orthop Surg Res       Date:  2014-07-19       Impact factor: 2.359

9.  Post-THA gait training to improve pelvic obliquity and decrease leg length discrepancy in DDH patients: a retrospective study.

Authors:  Xinyu Qi; Ke Jie; Jinlun Chen; Houran Cao; John A Koch; Jie Li; Jianchun Zeng; Wenjun Feng; Yirong Zeng
Journal:  J Int Med Res       Date:  2020-03       Impact factor: 1.671

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.