Literature DB >> 10149194

Comparison of transthoracic and transesophageal assessment of prosthetic valve dysfunction.

L B Daniel1, L E Grigg, R D Weisel, H Rakowski.   

Abstract

Transesophageal echocardiography has added another dimension to the assessment of prosthetic valve dysfunction with high-resolution images that allow for more detailed structural evaluation of tissue and mechanical valves. This study is a retrospective analysis of 140 prosthetic valves (90 tissue, 50 mechanical) in the mitral (89), aortic (45), and tricuspid (6) position in 116 patients studied by transthoracic and transesophageal echocardiography techniques. Transesophageal echocardiography was consistently better than the transthoracic technique in the evaluation of structural abnormalities of tissue valves in the mitral and aortic positions with respect to leaflet thickening, prolapse, flail, and vegetations. With transesophageal echocardiography, five tissue mitral valves had flail leaflets that were not identified by the transthoracic technique. Transesophageal echocardiography was better than transthoracic in the detection, quantification, and localization of prosthetic mitral regurgitation. Physiological mitral regurgitation was detected in 31 valves by transesophageal echocardiography compared to seven by transthoracic technique. By transesophageal echocardiography, mitral regurgitation was paravalvular in 24% compared with 4% by transthoracic technique. Left atrial spontaneous contrast was seen in 42% of the patients with a mitral prosthesis detected only by transesophageal echocardiography. Six patients had left atrial or left atrial appendage thrombus and in five patients they were detected only by transesophageal echocardiography. We conclude that transesophageal echocardiography should be a complimentary test to transthoracic studies in patients with suspected prosthetic valve dysfunction or for the follow-up of older tissue valves.

Entities:  

Mesh:

Year:  1990        PMID: 10149194     DOI: 10.1111/j.1540-8175.1990.tb00352.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  6 in total

1.  Assessing prosthetic mitral valve regurgitation by transoesophageal echo/Doppler.

Authors:  P S Rahko
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

Review 2.  Echocardiographic evaluation of prosthetic heart valves.

Authors:  Haïfa Mahjoub; Philippe Pibarot; Jean-Gaston Dumesnil
Journal:  Curr Cardiol Rep       Date:  2015-06       Impact factor: 2.931

3.  Routine cine-CMR for prosthesis-associated mitral regurgitation: a multicenter comparison to echocardiography.

Authors:  Lauren A Simprini; Anika Afroz; Mitchell A Cooper; Igor Klem; Christoph Jensen; Raymond J Kim; Monvadi B Srichai; John F Heitner; Michael Sood; Elizabeth Chandy; Dipan J Shah; Juan Lopez-Mattei; Robert W Biederman; John D Grizzard; Anthon Fuisz; Kambiz Ghafourian; Afshin Farzaneh-Far; Jonathan Weinsaft
Journal:  J Heart Valve Dis       Date:  2014-09

Review 4.  Diagnostic evaluation of left-sided prosthetic heart valve dysfunction.

Authors:  Jesse Habets; Ricardo P Budde; Petr Symersky; Renee B van den Brink; Bas A de Mol; Willem P Mali; Lex A van Herwerden; Steven A Chamuleau
Journal:  Nat Rev Cardiol       Date:  2011-05-17       Impact factor: 32.419

5.  An unusual Doppler-echocardiographic finding in case of a Björk-Shiley mitral prosthetic valve thrombosis.

Authors:  T Forster; A Varga; A Péterffy; M Csanády
Journal:  Int J Card Imaging       Date:  1992

6.  A Complicated Case of a Paravalvular Leak Following Mitral Valve Replacement.

Authors:  Kashmala Khan; Pahnwat T Taweesedt; Sridhar Venkatachalam; Salim Surani
Journal:  Cureus       Date:  2020-12-04
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.