Literature DB >> 10100058

Arm position is important for blood pressure measurement.

R T Netea1, J W Lenders, P Smits, T Thien.   

Abstract

AIM: To test the effect of positioning the arm on the arm-rest of a common chair, below the officially recommended right atrial level, on the blood pressure (BP) readings in a group of out-patients. PATIENTS AND METHODS: A group of 69 patients (58 hypertensives; 39 males; mean +/- s.d. age 54.1 +/- 16.0 years) participated in the present study. BP and heart rate values obtained in each of the following two positions were compared: (1) sitting with the arms supported on the arm-rests of the chair and (2) sitting with the arms supported at the level of the mid-sternum (the approximation of the right atrial level). BP was measured simultaneously at both arms, with a mercury sphygmomanometer at the right arm and with an automatic oscillometric device at the left arm.
RESULTS: Both the systolic and diastolic BPs were significantly higher (P < 0.0001) when the arm was placed on the arm-rest of the chair than at the right atrial level. The same differences +/- s.d. in BP between the two positions were obtained with both measurement techniques: 9.7 +/- 9.4 mm Hg (systolic) and 10.8 +/- 5.8 mm Hg (diastolic) with the mercury sphygmomanometer and respectively 7.3 +/- 8.9 mm Hg and 8.3 +/- 6.0 mm Hg with the oscillometric device. No difference in the heart rate was found between the two positions.
CONCLUSIONS: Placing the patient's arms on the arm-rest of the chair instead of at the reference right atrial level, BP measurement will result in spuriously elevated BP values. This may be of great importance for the diagnosis and the subsequent treatment decisions for patients with hypertension.

Entities:  

Mesh:

Year:  1999        PMID: 10100058     DOI: 10.1038/sj.jhh.1000720

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  7 in total

1.  Knowledge of accurate blood pressure measurement procedures in chiropractic students.

Authors:  Angela M Crosley; James R La Rose
Journal:  J Chiropr Educ       Date:  2013-06-27

2.  Reduction in finger blood flow induced by hand-transmitted vibration: effect of hand elevation.

Authors:  Ying Ye; Marcella Mauro; Massimo Bovenzi; Michael J Griffin
Journal:  Int Arch Occup Environ Health       Date:  2015-02-08       Impact factor: 3.015

3.  Do physicians measure patients' blood pressure, and are those measurements reliable?

Authors:  Şükrü Ulusoy; Gülsüm Özkan; Beyhan Güvercin; Yeliz Sökmen; Yunus Erdem
Journal:  J Hum Hypertens       Date:  2018-02-08       Impact factor: 3.012

4.  Prevalence of pseudoresistant hypertension due to inaccurate blood pressure measurement.

Authors:  Hemal Bhatt; Mohammed Siddiqui; Eric Judd; Suzanne Oparil; David Calhoun
Journal:  J Am Soc Hypertens       Date:  2016-03-30

5.  Challenges in standardization of blood pressure measurement at the population level.

Authors:  Hanna Tolonen; Päivikki Koponen; Androniki Naska; Satu Männistö; Grazyna Broda; Tarja Palosaari; Kari Kuulasmaa
Journal:  BMC Med Res Methodol       Date:  2015-04-10       Impact factor: 4.615

Review 6.  Sources of inaccuracy in the measurement of adult patients' resting blood pressure in clinical settings: a systematic review.

Authors:  Noa Kallioinen; Andrew Hill; Mark S Horswill; Helen E Ward; Marcus O Watson
Journal:  J Hypertens       Date:  2017-03       Impact factor: 4.844

7.  Office blood pressure measurement practices among community health providers (medical and paramedical) in northern district of India.

Authors:  Bishav Mohan; Naved Aslam; Upma Ralhan; Sarit Sharma; Naveen Gupta; Vivudh Pratap Singh; Shibba Takkar; G S Wander
Journal:  Indian Heart J       Date:  2014-08-06