Literature DB >> 10080338

Contact or immersion technique for axial length measurement?

A Watson1, R Armstrong.   

Abstract

PURPOSE: The purpose of the present study was to determine whether contact and immersion A-scan techniques produce comparable measures of the magnitude of eye axial length.
METHOD: A prospective study in which 225 consecutive patients scheduled for cataract surgery in a private day surgery setting had axial lengths measured with an Alcon Ocuscan machine (Alcon Australia, Frenchs Forest, NSW, Australia) using both contact and immersion techniques. Twelve patients had both techniques repeated on a separate occasion.
RESULTS: Measurements of eye axial length obtained by the immersion technique averaged 0.1 mm longer than those obtained by the contact technique. A difference in axial length values was confirmed in eyes subjected to repeated measurements.
CONCLUSIONS: Both techniques give consistent results, but the difference between axial lengths measured by the two techniques has implications for choice of intra-ocular lens power.

Entities:  

Mesh:

Year:  1999        PMID: 10080338     DOI: 10.1046/j.1440-1606.1999.00162.x

Source DB:  PubMed          Journal:  Aust N Z J Ophthalmol        ISSN: 0814-9763


  8 in total

1.  IOLMaster biometry: refractive results of 100 consecutive cases.

Authors:  H Eleftheriadis
Journal:  Br J Ophthalmol       Date:  2003-08       Impact factor: 4.638

2.  Comparison of optical low-coherence reflectometry and applanation ultrasound biometry on intraocular lens power calculation.

Authors:  Mirjana Bjeloš Rončević; Mladen Bušić; Ivan Cima; Biljana Kuzmanović Elabjer; Damir Bosnar; Daliborka Miletić
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-09-18       Impact factor: 3.117

3.  Axial length measurements by contact and immersion techniques in pediatric eyes with cataract.

Authors:  Rupal H Trivedi; M Edward Wilson
Journal:  Ophthalmology       Date:  2010-10-29       Impact factor: 12.079

4.  Refractive outcomes comparison between the Lenstar LS 900® optical biometry and immersion A-scan ultrasound.

Authors:  Palanyraj Naicker; Siva Sundralingam; Mohammadreza Peyman; Azida Juana; Nor Fadhilah Mohamad; Maung Maung Win; Angela Loo; Visvaraja Subrayan
Journal:  Int Ophthalmol       Date:  2014-07-15       Impact factor: 2.031

5.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

6.  Lens thickness with age and accommodation by optical coherence tomography.

Authors:  Kathryn Richdale; Mark A Bullimore; Karla Zadnik
Journal:  Ophthalmic Physiol Opt       Date:  2008-09       Impact factor: 3.117

7.  Comparison of ocular biometry measurements by applanation and immersion A-scan techniques.

Authors:  Dupe S Ademola-Popoola; Donald A Nzeh; Sadiat E Saka; Lateefat B Olokoba; Tokunbo S Obajolowo
Journal:  J Curr Ophthalmol       Date:  2016-02-09

8.  Risk factors affecting cataract surgery outcome: The Malaysian cataract surgery registry.

Authors:  Geng-Yi Yong; Jelinar Mohamed-Noor; Mohamad Aziz Salowi; Tassha Hilda Adnan; Mimiwati Zahari
Journal:  PLoS One       Date:  2022-09-21       Impact factor: 3.752

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.