Literature DB >> 10077514

LocaLisa: new technique for real-time 3-dimensional localization of regular intracardiac electrodes.

F H Wittkampf1, E F Wever, R Derksen, A A Wilde, H Ramanna, R N Hauer, E O Robles de Medina.   

Abstract

BACKGROUND: Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. METHODS AND
RESULTS: We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4+/-1.1 mm.
CONCLUSIONS: This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.

Entities:  

Mesh:

Year:  1999        PMID: 10077514     DOI: 10.1161/01.cir.99.10.1312

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  54 in total

1.  Benefits of new catheter mapping technology: fact or fiction?

Authors:  S Saksena
Journal:  J Interv Card Electrophysiol       Date:  2000-06       Impact factor: 1.900

Review 2.  Telomerase-independent mechanisms of telomere elongation.

Authors:  H Biessmann; J M Mason
Journal:  Cell Mol Life Sci       Date:  2003-11       Impact factor: 9.261

3.  Stereotactic magnetic resonance guidance for anatomically targeted ablations of the fossa ovalis and the left atrium.

Authors:  Timm Dickfeld; Hugh Calkins; Menekhem Zviman; Glenn Meininger; Lars Lickfett; Ariel Roguin; Albert C Lardo; Ronald Berger; Henry Halperin; Stephen B Solomon
Journal:  J Interv Card Electrophysiol       Date:  2004-10       Impact factor: 1.900

4.  Use of a non-fluoroscopic catheter navigation system for pulmonary vein isolation.

Authors:  Mark A Wood; Paul J Christman; Richard K Shepard; Kenneth A Ellenbogen
Journal:  J Interv Card Electrophysiol       Date:  2004-04       Impact factor: 1.900

5.  Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs conventional pulmonary venography and study of reproducibility.

Authors:  Ruzica Maksimović; Filippo Cademartiri; Marcoen Scholten; Luc J Jordaens; Peter M T Pattynama
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

6.  First in vivo use of a capacitive micromachined ultrasound transducer array-based imaging and ablation catheter.

Authors:  Douglas N Stephens; Uyen T Truong; Amin Nikoozadeh; Omer Oralkan; Chi Hyung Seo; Jonathan Cannata; Aaron Dentinger; Kai Thomenius; Alan de la Rama; Tho Nguyen; Feng Lin; Pierre Khuri-Yakub; Aman Mahajan; Kalyanam Shivkumar; Matt O'Donnell; David J Sahn
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

7.  Patient-specific generation of the Purkinje network driven by clinical measurements of a normal propagation.

Authors:  Christian Vergara; Simone Palamara; Domenico Catanzariti; Fabio Nobile; Elena Faggiano; Cesarino Pangrazzi; Maurizio Centonze; Massimiliano Maines; Alfio Quarteroni; Giuseppe Vergara
Journal:  Med Biol Eng Comput       Date:  2014-08-24       Impact factor: 2.602

Review 8.  Registration of three dimensional left atrial images with interventional systems.

Authors:  Jasbir Sra
Journal:  Heart       Date:  2005-08       Impact factor: 5.994

9.  Slow pathway ablation in a 5-year-old boy with atrioventricular septal defect: value of cryoenergy application.

Authors:  T Kriebel; H Schneider; M Sigler; T Paul
Journal:  Clin Res Cardiol       Date:  2006-09-28       Impact factor: 5.460

10.  Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Authors:  Ehud J Schmidt; Zion T H Tse; Tobias R Reichlin; Gregory F Michaud; Ronald D Watkins; Kim Butts-Pauly; Raymond Y Kwong; William Stevenson; Jeffrey Schweitzer; Israel Byrd; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.