Literature DB >> 10076970

The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery.

M J Murphy1.   

Abstract

A new radiographic patient positioning technique developed for radiosurgery has been analyzed to show the effect of computed tomography (CT) slice thickness on the precision of target localization during treatment. The positioning technique establishes the pose of the patient's anatomy during treatment by comparing treatment room radiographs with digitally reconstructed radiographs derived from a CT study. The measured pose is then used to align the x-ray therapy beam with the treatment site, without resorting to mechanical fixation. The technique has been found to be sensitive to submillimeter changes in skull position, which is the level of precision desired for radiosurgery. In this report it is shown that the precision of head localization improves by a factor of 2 when the CT slice thickness is reduced from 3.0 to 1.5 mm. This indicates that, in radiosurgical applications, image-guided beam alignment can be significantly influenced by the spatial resolution of the reference CT study. This result is relevant to all high-precision radiographic positioning techniques that utilize CT images.

Entities:  

Mesh:

Year:  1999        PMID: 10076970     DOI: 10.1118/1.598500

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Novel correction methods as alternatives for the six-dimensional correction in CyberKnife treatment.

Authors:  Osamu Suzuki; Hiroya Shiomi; Satoaki Nakamura; Fumitoshi Nakayama; Yasuo Yoshioka; Takehiro Inoue
Journal:  Radiat Med       Date:  2007-01-25

2.  A Systematic Analysis of Errors in Target Localization and Treatment Delivery for Stereotactic Radiosurgery Using 2D/3D Image Registration.

Authors:  Hao Xu; Stephen Brown; Indrin J Chetty; Ning Wen
Journal:  Technol Cancer Res Treat       Date:  2016-08-31

3.  Head to head comparison of two commercial phantoms used for SRS QA.

Authors:  Vikren Sarkar; Long Huang; Yu-Huei Jessica Huang; Martin W Szegedi; Prema Rassiah-Szegedi; Hui Zhao; Bill J Salter
Journal:  J Radiosurg SBRT       Date:  2016

4.  The effect of longitudinal CT resolution and pixel size (FOV) on target delineation and treatment planning in stereotactic radiosurgery.

Authors:  Maria R Bellon; M Salim Siddiqui; Samuel Ryu; Indrin J Chetty
Journal:  J Radiosurg SBRT       Date:  2014

5.  Finite Element Analysis Examining the Effects of Cam FAI on Hip Joint Mechanical Loading Using Subject-Specific Geometries During Standing and Maximum Squat.

Authors:  K C Geoffrey Ng; Gholamreza Rouhi; Mario Lamontagne; Paul E Beaulé
Journal:  HSS J       Date:  2012-09-07

6.  Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT.

Authors:  Jinkoo Kim; Ning Wen; Jian-Yue Jin; Nicole Walls; Sangroh Kim; Haisen Li; Lei Ren; Yimei Huang; Anthony Doemer; Kathleen Faber; Tina Kunkel; Ahssan Balawi; Kimberly Garbarino; Kenneth Levin; Samir Patel; Munther Ajlouni; Brett Miller; Teamor Nurushev; Calvin Huntzinger; Raymond Schulz; Indrin J Chetty; Benjamin Movsas; Samuel Ryu
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

7.  Clinical assessment and characterization of a dual tube kilovoltage X-ray localization system in the radiotherapy treatment room.

Authors:  Sung-Woo Lee; Jian-Yue Jin; Huaiqun Guan; Flavious Martin; Jae Ho Kim; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2008-01-13       Impact factor: 2.102

8.  Performance evaluation of an automated image registration algorithm using an integrated kilovoltage imaging and guidance system.

Authors:  Timothy Fox; Calvin Huntzinger; Peter Johnstone; Tomi Ogunleye; Eric Elder
Journal:  J Appl Clin Med Phys       Date:  2006-02-15       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.