Literature DB >> 10066671

Balloon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury.

C Rogers1, D Y Tseng, J C Squire, E R Edelman.   

Abstract

Endovascular stents expand the arterial lumen more than balloon angioplasty and reduce rates of restenosis after coronary angioplasty in selected patients. Understanding the factors involved in vascular injury imposed during stent deployment may allow optimization of stent design and stent-placement protocols so as to limit vascular injury and perhaps reduce restenosis. Addressing the hypothesis that a previously undescribed mechanism of vascular injury during stent deployment is balloon-artery interaction, we have used finite element analysis to model how balloon-artery contact stress and area depend on stent-strut geometry, balloon compliance, and inflation pressure. We also examined superficial injury during deployment of stents of varied design in vivo and in a phantom model ex vivo to show that balloon-induced damage can be modulated by altering stent design. Our results show that higher inflation pressures, wider stent-strut openings, and more compliant balloon materials cause markedly larger surface-contact areas and contact stresses between stent struts. Appreciating that the contact stress and contact area are functions of placement pressure, stent geometry, and balloon compliance may help direct development of novel stent designs and stent-deployment protocols so as to minimize vascular injury during stenting and perhaps to optimize long-term outcomes.

Entities:  

Mesh:

Year:  1999        PMID: 10066671     DOI: 10.1161/01.res.84.4.378

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  26 in total

1.  Mechanical behavior of fully expanded commercially available endovascular coronary stents.

Authors:  Josip Tambaca; Suncica Canic; Mate Kosor; R David Fish; David Paniagua
Journal:  Tex Heart Inst J       Date:  2011

Review 2.  The importance of the endothelium in atherothrombosis and coronary stenting.

Authors:  Fumiyuki Otsuka; Aloke V Finn; Saami K Yazdani; Masataka Nakano; Frank D Kolodgie; Renu Virmani
Journal:  Nat Rev Cardiol       Date:  2012-05-22       Impact factor: 32.419

3.  A finite element study on variations in mass transport in stented porcine coronary arteries based on location in the coronary arterial tree.

Authors:  Joseph T Keyes; Bruce R Simon; Jonathan P Vande Geest
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

4.  Mechanical Criterion for the Rupture of a Cell Membrane under Compression.

Authors:  David Gonzalez-Rodriguez; Lionel Guillou; François Cornat; Julie Lafaurie-Janvore; Avin Babataheri; Emmanuel de Langre; Abdul I Barakat; Julien Husson
Journal:  Biophys J       Date:  2016-12-20       Impact factor: 4.033

5.  The stentable in vitro artery: an instrumented platform for endovascular device development and optimization.

Authors:  Elizabeth E Antoine; François P Cornat; Abdul I Barakat
Journal:  J R Soc Interface       Date:  2016-12       Impact factor: 4.118

6.  Extent of flow recirculation governs expression of atherosclerotic and thrombotic biomarkers in arterial bifurcations.

Authors:  Jordi Martorell; Pablo Santomá; Kumaran Kolandaivelu; Vijaya B Kolachalama; Pedro Melgar-Lesmes; José J Molins; Lawrence Garcia; Elazer R Edelman; Mercedes Balcells
Journal:  Cardiovasc Res       Date:  2014-05-19       Impact factor: 10.787

7.  Collagen Matrix Remodeling in Stented Pulmonary Arteries after Transapical Heart Valve Replacement.

Authors:  Samaneh Ghazanfari; Anita Driessen-Mol; Simon P Hoerstrup; Frank P T Baaijens; Carlijn V C Bouten
Journal:  Cells Tissues Organs       Date:  2016-03-19       Impact factor: 2.481

8.  A combination of experimental and numerical methods to investigate the role of strain rate on the mechanical properties and collagen fiber orientations of the healthy and atherosclerotic human coronary arteries.

Authors:  Alireza Karimi; Seyyed Mohammadali Rahmati; Toshihiro Sera; Susumu Kudo; Mahdi Navidbakhsh
Journal:  Bioengineered       Date:  2016-09-02       Impact factor: 3.269

9.  Coronary artery stretch versus deep injury in the development of in-stent neointima.

Authors:  J Gunn; N Arnold; K H Chan; L Shepherd; D C Cumberland; D C Crossman
Journal:  Heart       Date:  2002-10       Impact factor: 5.994

10.  Is coronary stent deployment and remodeling affected by predilatation? An intravascular ultrasound randomized study Stenting with or without predilation: an IVUS study.

Authors:  Jacques Boschat; Hervé Le Breton; P Commeau; Bernard Huret; Marc Bedossa; Martine Gilard
Journal:  Int J Cardiovasc Imaging       Date:  2002-12       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.