High-frequency hearing influences lower-frequency distortion-product otoacoustic emissions.

D J Arnold1, B L Lonsbury-Martin, G K Martin.   

Abstract

OBJECTIVES: The primary goal of this study was to test the ability of 2f1-f2 distortion-product otoacoustic emissions (DPOAEs) to detect reduced cochlear function in the presence of normal behavioral sensitivity.
DESIGN: A prospective study was performed in normal-hearing young adults using simple and complex regression analyses to clarify the relationship between ultra-high frequency (UHF) hearing and DPOAE levels at lower frequencies, as well as the influence of hearing levels for frequencies within the conventional test range and subject age on this association.
METHODS: Average DPOAE levels between 4 to 8 kHz, which were elicited by equilevel primary tones of low to moderate levels, were measured as level-frequency functions, or distortion-product (DP) grams, and related to the mean UHF hearing levels from 11.2 to 20 kHz. The median hearing level for the UHF hearing was used to separate subjects into good and poor UHF hearers. This distinction was then used to compare DPOAE levels from 4 to 8 kHz for the 2 groups to determine if UHF hearing status influenced DPOAE levels at lower frequencies.
RESULTS: Simple regression analysis revealed that the 4-to 8-kHz DPOAE levels were significantly correlated with the pure-tone average (PTA) from 11.2 to 20 kHz. However, the PTA for 4 and 8 kHz was also significantly correlated with the PTA for UHF hearing. Further multiple regression analyses revealed that UHF hearing significantly and uniquely accounted for approximately 14% of the variance in DPOAE levels from 4 to 8 kHz for most of the primary-tone level combinations. In contrast, neither the PTA for the conventional hearing range nor subject age contributed significantly to the DPOAE variance.
CONCLUSIONS: The findings suggest that UHF hearing influences DPOAEs at significantly lower frequencies because emissions are sensitive to subtle changes in outer hair cells not yet detected by pure-tone thresholds in this region or because alterations in the basal cochlea affect the generation of lower-frequency DPOAEs originating from more apical cochlear regions.

Mesh:

Year:  1999        PMID: 10037289     DOI: 10.1001/archotol.125.2.215

Source DB:  PubMed          Journal:  Arch Otolaryngol Head Neck Surg        ISSN: 0886-4470


  21 in total

1.  Mild Maternal Iron Deficiency Anemia Induces Hearing Impairment Associated with Reduction of Ribbon Synapse Density and Dysregulation of VGLUT3, Myosin VIIa, and Prestin Expression in Young Guinea Pigs.

Authors:  Fei Yu; Shuai Hao; Bo Yang; Yue Zhao; Wenyue Zhang; Jun Yang
Journal:  Neurotox Res       Date:  2016-02-25       Impact factor: 3.911

2.  Prophylactic etanercept treatment in cisplatin ototoxicity.

Authors:  Sinem Dasli; Murat Topdag; Ahmet Mutlu; Ahmet Kara; Murat Ozturk
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-07-20       Impact factor: 2.503

3.  Tuning of SFOAEs Evoked by Low-Frequency Tones Is Not Compatible with Localized Emission Generation.

Authors:  Karolina K Charaziak; Jonathan H Siegel
Journal:  J Assoc Res Otolaryngol       Date:  2015-03-27

4.  Distortion-product otoacoustic emission test performance for ototoxicity monitoring.

Authors:  Kelly M Reavis; Garnett McMillan; Donald Austin; Frederick Gallun; Stephen A Fausti; Jane S Gordon; Wendy J Helt; Dawn Konrad-Martin
Journal:  Ear Hear       Date:  2011-02       Impact factor: 3.570

5.  Multivariate DPOAE metrics for identifying changes in hearing: perspectives from ototoxicity monitoring.

Authors:  Dawn Konrad-Martin; Kelly M Reavis; Garnett P McMillan; Marilyn F Dille
Journal:  Int J Audiol       Date:  2012-02       Impact factor: 2.117

6.  Children with autism spectrum disorder have reduced otoacoustic emissions at the 1 kHz mid-frequency region.

Authors:  Loisa Bennetto; Jessica M Keith; Paul D Allen; Anne E Luebke
Journal:  Autism Res       Date:  2016-07-12       Impact factor: 5.216

7.  Distortion-Product Otoacoustic Emission Measured Below 300 Hz in Normal-Hearing Human Subjects.

Authors:  Anders T Christensen; Rodrigo Ordoñez; Dorte Hammershøi
Journal:  J Assoc Res Otolaryngol       Date:  2016-11-21

8.  Evidence for basal distortion-product otoacoustic emission components.

Authors:  Glen K Martin; Barden B Stagner; Brenda L Lonsbury-Martin
Journal:  J Acoust Soc Am       Date:  2010-05       Impact factor: 1.840

9.  Effect of sepsis and systemic inflammatory response syndrome on neonatal hearing screening outcomes following gentamicin exposure.

Authors:  Campbell P Cross; Selena Liao; Zachary D Urdang; Priya Srikanth; Angela C Garinis; Peter S Steyger
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2015-09-09       Impact factor: 1.675

10.  Proposed comprehensive ototoxicity monitoring program for VA healthcare (COMP-VA).

Authors:  Dawn Konrad-Martin; Kelly M Reavis; Garnett McMillan; Wendy J Helt; Marilyn Dille
Journal:  J Rehabil Res Dev       Date:  2014
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.