INTRODUCTION: A nonbehavioral method for monitoring ototoxicity in patients treated with cisplatin is needed because patients enduring chemotherapy may not be well or cooperative enough to undergo repeated hearing tests. Distortion-product otoacoustic emissions (DPOAEs) provide a nonbehavioral measure of auditory function that is sensitive to cisplatin exposure. However, interpreting DPOAE findings in the context of ototoxicity monitoring requires that their accuracy be determined in relation to a clinically accepted gold standard test. OBJECTIVES: Among patients receiving cisplatin for the treatment of cancer, we sought to (1) identify the combination of DPOAE metrics and ototoxicity risk factors that best classified ears with and without ototoxic-induced hearing changes; and (2) evaluate the test performance achieved by the composite measure as well as by DPOAEs alone. DESIGN: Odds of experiencing hearing changes at a given patient visit were determined using data collected prospectively from 24 Veterans receiving cisplatin. Pure-tone thresholds were examined within an octave of each subject's high-frequency hearing limit. DPOAE were collected as a set of four response growth (input/output) functions near the highest f2 frequency that yielded a robust response at L2 = L1 = 65 dB SPL. Logistic regression modeled the risk of hearing change using several DPOAE metrics, drug treatment factors, and other patient factors as independent variables. An optimal discriminant function was derived by reducing the model so that only statistically significant variables were included. Receiver operating characteristic curve analyses were used to evaluate test performance. RESULTS: At higher cisplatin doses, ears with better hearing at baseline were more likely to exhibit ototoxic hearing changes than those with poorer hearing. Measures of pre-exposure hearing, cumulative drug dose, and DPOAEs generated a highly accurate discriminant function with a cross-validated area under the receiver operating characteristic curve of 0.9. DPOAEs alone also provided an indication of ototoxic hearing change when measured at the highest DPOAE test frequency that yielded a robust response. CONCLUSIONS: DPOAEs alone and especially in combination with pre-exposure hearing and cisplatin dose provide an indication of whether or not hearing has changed as a result of cisplatin administration. These promising results need to be validated in a separate sample.
INTRODUCTION: A nonbehavioral method for monitoring ototoxicity in patients treated with cisplatin is needed because patients enduring chemotherapy may not be well or cooperative enough to undergo repeated hearing tests. Distortion-product otoacoustic emissions (DPOAEs) provide a nonbehavioral measure of auditory function that is sensitive to cisplatin exposure. However, interpreting DPOAE findings in the context of ototoxicity monitoring requires that their accuracy be determined in relation to a clinically accepted gold standard test. OBJECTIVES: Among patients receiving cisplatin for the treatment of cancer, we sought to (1) identify the combination of DPOAE metrics and ototoxicity risk factors that best classified ears with and without ototoxic-induced hearing changes; and (2) evaluate the test performance achieved by the composite measure as well as by DPOAEs alone. DESIGN: Odds of experiencing hearing changes at a given patient visit were determined using data collected prospectively from 24 Veterans receiving cisplatin. Pure-tone thresholds were examined within an octave of each subject's high-frequency hearing limit. DPOAE were collected as a set of four response growth (input/output) functions near the highest f2 frequency that yielded a robust response at L2 = L1 = 65 dB SPL. Logistic regression modeled the risk of hearing change using several DPOAE metrics, drug treatment factors, and other patient factors as independent variables. An optimal discriminant function was derived by reducing the model so that only statistically significant variables were included. Receiver operating characteristic curve analyses were used to evaluate test performance. RESULTS: At higher cisplatin doses, ears with better hearing at baseline were more likely to exhibit ototoxic hearing changes than those with poorer hearing. Measures of pre-exposure hearing, cumulative drug dose, and DPOAEs generated a highly accurate discriminant function with a cross-validated area under the receiver operating characteristic curve of 0.9. DPOAEs alone also provided an indication of ototoxic hearing change when measured at the highest DPOAE test frequency that yielded a robust response. CONCLUSIONS: DPOAEs alone and especially in combination with pre-exposure hearing and cisplatin dose provide an indication of whether or not hearing has changed as a result of cisplatin administration. These promising results need to be validated in a separate sample.
Authors: S A Fausti; J A Henry; W J Helt; D S Phillips; R H Frey; D Noffsinger; V D Larson; C G Fowler Journal: Ear Hear Date: 1999-12 Impact factor: 3.570
Authors: Dawn Konrad-Martin; Kenneth E James; Jane S Gordon; Kelly M Reavis; David S Phillips; Gene W Bratt; Stephen A Fausti Journal: J Am Acad Audiol Date: 2010-05 Impact factor: 1.664
Authors: Jeany M Rademaker-Lakhai; Mirjam Crul; Lot Zuur; Paul Baas; Jos H Beijnen; Yvonne J W Simis; Nico van Zandwijk; Jan H M Schellens Journal: J Clin Oncol Date: 2006-02-20 Impact factor: 44.544
Authors: Hyejeong Hong; David W Dowdy; Kelly E Dooley; Howard W Francis; Chakra Budhathoki; Hae-Ra Han; Jason E Farley Journal: Am J Audiol Date: 2020-04-22 Impact factor: 1.493
Authors: Débora Cristina de Oliveira Bezerra; Renata Oliveira de Barcelos; Ellen Carvalho de Castro; Claudia Cristina Jardim Duarte; Raquel de Vasconcellos Carvalhaes Oliveira; Tania Salgado de Sousa Torraca; Maria Helena de Araújo-Melo; Frederico Pereira Bom Braga; Benivaldo Ramos Ferreira Terceiro; Lúcia Regina do Nascimento Brahim Paes; Armando de Oliveira Schubach; Cláudia Maria Valete-Rosalino Journal: PLoS One Date: 2017-01-03 Impact factor: 3.240
Authors: Dawn Konrad-Martin; Kristin Knight; Garnett P McMillan; Laura E Dreisbach; Elsa Nelson; Marilyn Dille Journal: Ear Hear Date: 2020 Mar/Apr Impact factor: 3.570
Authors: Marilyn F Dille; Debra Wilmington; Garnett P McMillan; Wendy Helt; Stephen A Fausti; Dawn Konrad-Martin Journal: J Am Acad Audiol Date: 2012 Jul-Aug Impact factor: 1.664