Literature DB >> 10030661

Temperature measurement using echo-shifted FLASH at low field for interventional MRI.

Y C Chung1, J L Duerk, A Shankaranarayanan, M Hampke, E M Merkle, J S Lewin.   

Abstract

We investigated the feasibility of using echo-shifted fast low-angle shot (FLASH) for temperature-monitored thermo-therapeutic procedures in a 0.2 T interventional magnetic resonance (MR) scanner. Based on the proton resonance frequency shift technique, modified echo-shifted FLASH has sufficiently high signal-to-noise ratio to provide accurate temperature maps with short scan times, i.e., 5 seconds in phantoms (TR = 20.5 msec; effective TE = 30 msec; one echo shift; NSA = 2) and ex vivo experiments (TR = 19.4 msec; effective TE = 28.9 msec; one echo shift; NSA = 2) and 3 seconds (TR = 19.4 msec; effective TE = 28.9 msec, one echo shift; NSA 1) for an in vivo case. The proton resonance frequency shifts with temperature observed in a 0.2 T MR scanner using this sequence were -0.0072 ppm/degrees C (temperature uncertainty = +/-2.5 degrees C) for polyacrylamide phantoins and -0.0086 ppm/degrees C (temperature uncertainty = +/- 1 degrees C) for ex vivo bovine liver. These experiments demonstrated that echo-shifted FLASH is a viable method for low-field temperature monitoring despite the decreased signal and decreased phase sensitivity compared with its counterpart in a 1.5 T MR imaging system. The improved temporal resolution of temperature images, now possible in low-field interventional MR systems using echo-shifted FLASH, will allow clinicians more accurate monitoring of interstitial ablation in MR-guided interventional procedures.

Entities:  

Mesh:

Year:  1999        PMID: 10030661     DOI: 10.1002/(sici)1522-2586(199901)9:1<138::aid-jmri18>3.0.co;2-a

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

1.  MR monitoring of tumour thermal therapy.

Authors:  D Germain; P Chevallier; A Laurent; H Saint-Jalmes
Journal:  MAGMA       Date:  2001-08       Impact factor: 2.310

Review 2.  Stem cell therapy: MRI guidance and monitoring.

Authors:  Dara L Kraitchman; Wesley D Gilson; Christine H Lorenz
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

3.  MR temperature monitoring applying the proton resonance frequency method in liver and kidney at 0.2 and 1.5 T: segment-specific attainable precision and breathing influence.

Authors:  Hansjörg Rempp; Petros Martirosian; Andreas Boss; Stephan Clasen; Antje Kickhefel; Markus Kraiger; Christina Schraml; Claus Claussen; Philippe Pereira; Fritz Schick
Journal:  MAGMA       Date:  2008-09-02       Impact factor: 2.310

4.  Temperature imaging of laser-induced thermotherapy (LITT) by MRI: evaluation of different sequences in phantom.

Authors:  Babak Bazrafshan; Frank Hübner; Parviz Farshid; Renate Hammerstingl; Jijo Paul; Vitali Vogel; Werner Mäntele; Thomas J Vogl
Journal:  Lasers Med Sci       Date:  2013-03-28       Impact factor: 3.161

Review 5.  Magnetic Resonance Image-Guided Focal Prostate Ablation.

Authors:  Sherif G Nour
Journal:  Semin Intervent Radiol       Date:  2016-09       Impact factor: 1.513

6.  Assessment of thermal effects of interstitial laser phototherapy on mammary tumors using proton resonance frequency method.

Authors:  Kelvin Le; Xiaosong Li; Daniel Figueroa; Rheal A Towner; Philippe Garteiser; Debra Saunders; Nataliya Smith; Hong Liu; Tomas Hode; Robert E Nordquist; Wei R Chen
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

7.  Whole-head rapid fMRI acquisition using echo-shifted magnetic resonance inverse imaging.

Authors:  Wei-Tang Chang; Aapo Nummenmaa; Thomas Witzel; Jyrki Ahveninen; Samantha Huang; Kevin Wen-Kai Tsai; Ying-Hua Chu; Jonathan R Polimeni; John W Belliveau; Fa-Hsuan Lin
Journal:  Neuroimage       Date:  2013-04-04       Impact factor: 6.556

Review 8.  MR fluoroscopy in vascular and cardiac interventions (review).

Authors:  Maythem Saeed; Steve W Hetts; Joey English; Mark Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-26       Impact factor: 2.357

9.  Quantitative MR thermometry based on phase-drift correction PRF shift method at 0.35 T.

Authors:  Yuping Chen; Mengke Ge; Rizwan Ali; Hejun Jiang; Xiaoyan Huang; Bensheng Qiu
Journal:  Biomed Eng Online       Date:  2018-04-10       Impact factor: 2.819