Literature DB >> 10030647

Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.

C Teissl1, C Kremser, E S Hochmair, I J Hochmair-Desoyer.   

Abstract

With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med-E1 Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetization, artifacts, induced voltages, and temperature increase were measured in worst case scenarios for the implant. In addition, stabilization experiments were performed. It was shown that most of the electromagnetic interferences between the cochlear implant and the 1.5 T scanner remained within acceptable limits. One exception is the torque on the internal magnet, which represents a hazard for patients with these cochlear implants. Therefore, MRI examination should only be performed if there is a strong medical indication, and certainly some assessment of the relative risks involved versus the risk of not providing the diagnostic capabilities of MRI, will have to be made. Appropriate safety measures should be taken.

Entities:  

Mesh:

Year:  1999        PMID: 10030647     DOI: 10.1002/(sici)1522-2586(199901)9:1<26::aid-jmri4>3.0.co;2-h

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  16 in total

1.  Electrode insertion depth in cochlear implantees estimated during surgery, on plain film radiographs and with electrode function testing.

Authors:  Robert H R Bettman; Adriaan F van Olphen; Frans W Zonneveld; Egbert H Huizing
Journal:  Eur Arch Otorhinolaryngol       Date:  2003-05-23       Impact factor: 2.503

Review 2.  Is magnetic resonance imaging still a contraindication in cochlear-implanted patients?

Authors:  Sebastien Schmerber; Emile Reyt; Jean-Pierre Lavieille
Journal:  Eur Arch Otorhinolaryngol       Date:  2003-01-16       Impact factor: 2.503

3.  Safety and compatibility of magnetic-controlled growing rods and magnetic resonance imaging.

Authors:  Henry R Budd; Oliver M Stokes; Judith Meakin; Jonathan Fulford; Michael Hutton
Journal:  Eur Spine J       Date:  2015-08-14       Impact factor: 3.134

4.  [Prevalence and complications of MRI scans of cochlear implant patients: German version].

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2016-03       Impact factor: 1.284

5.  Prevalence and complications of MRI scans of cochlear implant patients : English version.

Authors:  G Grupe; J Wagner; S Hofmann; A Stratmann; P Mittmann; A Ernst; I Todt
Journal:  HNO       Date:  2017-01       Impact factor: 1.284

6.  Artifacts caused by cochlear implants with non-removable magnets in 3T MRI: phantom and cadaveric studies.

Authors:  Omid Majdani; Thomas S Rau; Friedrich Götz; Martin Zimmerling; Minoo Lenarz; Thomas Lenarz; Robert Labadie; Martin Leinung
Journal:  Eur Arch Otorhinolaryngol       Date:  2009-07-23       Impact factor: 2.503

7.  Cochlear implant with a non-removable magnet: preliminary research at 3-T MRI.

Authors:  F Dubrulle; A Sufana Iancu; C Vincent; G Tourrel; O Ernst
Journal:  Eur Radiol       Date:  2013-01-10       Impact factor: 5.315

8.  Cortical activation patterns to spatially presented pure tone stimuli with different intensities measured by functional near-infrared spectroscopy.

Authors:  Günther Bauernfeind; Selina C Wriessnegger; Sabine Haumann; Thomas Lenarz
Journal:  Hum Brain Mapp       Date:  2018-03-08       Impact factor: 5.038

9.  Comparison of bandaging techniques to prevent cochlear implant magnet displacement following MRI.

Authors:  Martin Leinung; Andreas G Loth; Michaela Kroth; Iris Burck; Timo Stöver; Silke Helbig
Journal:  Eur Arch Otorhinolaryngol       Date:  2021-01-02       Impact factor: 2.503

Review 10.  Functional near-infrared spectroscopy for neuroimaging in cochlear implant recipients.

Authors:  Joe Saliba; Heather Bortfeld; Daniel J Levitin; John S Oghalai
Journal:  Hear Res       Date:  2016-02-13       Impact factor: 3.208

View more