Literature DB >> 10029152

Ligament graft initial fixation strength using biodegradable interference screws.

S Rupp1, R Seil, A Schneider, D M Kohn.   

Abstract

The objective of this study was to evaluate the initial fixation strength of three types of biodegradable interference screws [an Endo Fix, 7 x 25 mm polyglycolic acid, non-self-tapping (Acufex); a biodegradable interference screw, 7 x 23 mm poly-L-lactic acid, self-tapping (Arthrex); a Bioscrew, 7 x 25 mm poly-L-lactic acid, self-tapping (Linvatec)] in comparison to a titanium interference screw (Linvatec, 7 x 25 mm) in anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft. Porcine lower limbs were used. To control for specimen related bias, bone mineral density of each tibia was measured. All specimens were loaded to failure. Failure mode was determined by visual analysis. The maximum load to failure [mean (SD)] was 785 (87) N (titanium screw), 555 (60) N (Acufex), 592 (211) N (Arthrex), and 844 N (Linvatec). The primary fixation strength of the titanium screw and the Linvatec screw was significantly higher (p < 0.05) than the primary fixation strength of the Arthrex screw and the Acufex screw. There was no difference in bone mineral density between the groups. With respect to primary fixation strength, all biodegradable screws were strong enough to allow accelerated rehabilitation. From this point of view the biodegradable screws may be a reasonable alternative to titanium interference screws.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10029152     DOI: 10.1002/(sici)1097-4636(1999)48:1<70::aid-jbm12>3.0.co;2-p

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  5 in total

1.  Post-operative assessment of an implant fixation in anterior cruciate ligament reconstructive surgery.

Authors:  Mahmoud Chizari; Martyn Snow; Bin Wang
Journal:  J Med Syst       Date:  2010-05-02       Impact factor: 4.460

2.  Recurrent locking of knee joint caused by intraarticular migration of bioabsorbable tibial interference screw after arthroscopic ACL reconstruction.

Authors:  Andreas Appelt; Martin Baier
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-28       Impact factor: 4.342

3.  Post-operative analysis of ACL tibial fixation.

Authors:  Mahmoud Chizari; Martyn Snow; Bin Wang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-01-09       Impact factor: 4.342

4.  Close-looped graft suturing improves mechanical properties of interference screw fixation in ACL reconstruction.

Authors:  María Prado; Belén Martín-Castilla; Alejandro Espejo-Reina; José Miguel Serrano-Fernández; Ana Pérez-Blanca; Francisco Ezquerro
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-30       Impact factor: 4.342

5.  Torsional stability of interference screws derived from bovine bone--a biomechanical study.

Authors:  Joscha Bauer; Turgay Efe; Silke Herdrich; Leo Gotzen; Bilal Farouk El-Zayat; Jan Schmitt; Nina Timmesfeld; Markus Dietmar Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-01       Impact factor: 2.362

  5 in total