Literature DB >> 19132350

Post-operative analysis of ACL tibial fixation.

Mahmoud Chizari1, Martyn Snow, Bin Wang.   

Abstract

The main aims of the study were to describe the mechanical behaviour of the bone and tendon graft in ACL reconstruction. We also wanted to evaluate the stresses upon the tendon and try to relate these to modes of healing observed in animal studies. An MRI scan of a knee from a 22-year-old male patient, 3 months post ACL reconstruction, was used to generate a finite element model for assessing the stresses on the tendon and bone. A 200 N force, equivalent to the force during normal gait, was placed on the graft and the stress distribution recorded. The maximum stress was found on the tendon graft at the proximal end of the tibial tunnel. Direct tendon healing, which has been observed in animal studies, maybe as a result of the increased stress in this area.

Entities:  

Mesh:

Year:  2009        PMID: 19132350     DOI: 10.1007/s00167-008-0685-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  33 in total

1.  Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation.

Authors:  D G Nagarkatti; B P McKeon; B S Donahue; J P Fulkerson
Journal:  Am J Sports Med       Date:  2001 Jan-Feb       Impact factor: 6.202

2.  Ligament graft initial fixation strength using biodegradable interference screws.

Authors:  S Rupp; R Seil; A Schneider; D M Kohn
Journal:  J Biomed Mater Res       Date:  1999

3.  Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction.

Authors:  K P Black; M M Saunders; K C Stube; M J Moulton; C R Jacobs
Journal:  Am J Sports Med       Date:  2000 Nov-Dec       Impact factor: 6.202

4.  Tendon healing in a bone tunnel. Part II: Histologic analysis after biodegradable interference fit fixation in a model of anterior cruciate ligament reconstruction in sheep.

Authors:  Andreas Weiler; Reinhard F G Hoffmann; Hermann J Bail; Oliver Rehm; Norbert P Südkamp
Journal:  Arthroscopy       Date:  2002-02       Impact factor: 4.772

5.  A multidisciplinary study of the healing of an intraarticular anterior cruciate ligament graft in a goat model.

Authors:  C D Papageorgiou; C B Ma; S D Abramowitch; T D Clineff; S L Woo
Journal:  Am J Sports Med       Date:  2001 Sep-Oct       Impact factor: 6.202

6.  A bioengineering analysis of force actions at the knee in normal and pathological gait.

Authors:  I J Harrington
Journal:  Biomed Eng       Date:  1976-05

7.  Mechanical properties of primate vascularized vs. nonvascularized patellar tendon grafts; changes over time.

Authors:  D L Butler; E S Grood; F R Noyes; M L Olmstead; R B Hohn; S P Arnoczky; M G Siegel
Journal:  J Orthop Res       Date:  1989       Impact factor: 3.494

8.  Tendon healing in a bone tunnel differs at the tunnel entrance versus the tunnel exit: an effect of graft-tunnel motion?

Authors:  Scott A Rodeo; Sumito Kawamura; Hyon-Jeong Kim; Christian Dynybil; Liang Ying
Journal:  Am J Sports Med       Date:  2006-07-21       Impact factor: 6.202

9.  Tendon-healing in a bone tunnel. A biomechanical and histological study in the dog.

Authors:  S A Rodeo; S P Arnoczky; P A Torzilli; C Hidaka; R F Warren
Journal:  J Bone Joint Surg Am       Date:  1993-12       Impact factor: 5.284

10.  Fixation strength of interference screw fixation in bovine, young human, and elderly human cadaver knees: influence of insertion torque, tunnel-bone block gap, and interference.

Authors:  G A Brown; F Peña; T Grøntvedt; D Labadie; L Engebretsen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  1996       Impact factor: 4.342

View more
  5 in total

1.  Post-operative assessment of an implant fixation in anterior cruciate ligament reconstructive surgery.

Authors:  Mahmoud Chizari; Martyn Snow; Bin Wang
Journal:  J Med Syst       Date:  2010-05-02       Impact factor: 4.460

2.  Measurement of an intact knee kinematics using gait and fluoroscopic analysis.

Authors:  Amir Hossein Saveh; Hamid Reza Katouzian; Mahmoud Chizari
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-19       Impact factor: 4.342

3.  Resorbable screw and sheath versus resorbable interference screw and staples for ACL reconstruction: a comparison of two tibial fixation methods.

Authors:  Christian Carulli; Fabrizio Matassi; Stefano Soderi; Luigi Sirleo; Giovanni Munz; Massimo Innocenti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

4.  [Influence of lateral posterior tibial slope on tibial tunnel expansion after anatomical single-bundle anterior cruciate ligament reconstruction].

Authors:  Hao Luo; Xianxiang Xiang; Ruixin Li; Danmei Li; Weiming Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-06-15

5.  Novel anterior cruciate ligament graft fixation device reduces slippage.

Authors:  Mandi J Lopez; Allen Borne; W Todd Monroe; Prakash Bommala; Laura Kelly; Nan Zhang
Journal:  Med Devices (Auckl)       Date:  2013-05-14
  5 in total