Literature DB >> 9986862

Reproducibility and performance of the second-generation branched-DNA assay in routine quantification of human immunodeficiency virus type 1 RNA in plasma.

D G Murphy1, P Gonin, M Fauvel.   

Abstract

We examined the reproducibility of a second-generation branched-DNA (bDNA) assay (Quantiplex HIV RNA 2.0) for quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma by retesting 325 specimens on separate runs and on different lots. The performance of the bDNA test was also assessed by data analysis obtained during routine testing of 15,365 specimens. Upon retesting, 96 and 86% of specimens displaying RNA levels above 5,000 and between 500 and 5, 000 copies/ml, respectively, showed less than a 0.3 log10 (twofold) difference with their initial values. Assay variability was found to increase as viral load decreased. Overall, the bDNA version 2.0 assay was found to be a reproducible and efficient test for routine quantification of HIV-1 RNA in plasma.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 9986862      PMCID: PMC84566     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

Review 1.  Antiretroviral therapy for HIV infection in 1996. Recommendations of an international panel. International AIDS Society-USA.

Authors:  C C Carpenter; M A Fischl; S M Hammer; M S Hirsch; D M Jacobsen; D A Katzenstein; J S Montaner; D D Richman; M S Sáag; R T Schooley; M A Thompson; S Vella; P G Yeni; P A Volberding
Journal:  JAMA       Date:  1996-07-10       Impact factor: 56.272

Review 2.  HIV viral load markers in clinical practice.

Authors:  M S Saag; M Holodniy; D R Kuritzkes; W A O'Brien; R Coombs; M E Poscher; D M Jacobsen; G M Shaw; D D Richman; P A Volberding
Journal:  Nat Med       Date:  1996-06       Impact factor: 53.440

3.  Comparative evaluation of NASBA HIV-1 RNA QT, AMPLICOR-HIV monitor, and QUANTIPLEX HIV RNA assay, three methods for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  H Revets; D Marissens; S de Wit; P Lacor; N Clumeck; S Lauwers; G Zissis
Journal:  J Clin Microbiol       Date:  1996-05       Impact factor: 5.948

4.  Evaluation of a quality assurance program for quantitation of human immunodeficiency virus type 1 RNA in plasma by the AIDS Clinical Trials Group virology laboratories.

Authors:  B Yen-Lieberman; D Brambilla; B Jackson; J Bremer; R Coombs; M Cronin; S Herman; D Katzenstein; S Leung; H J Lin; P Palumbo; S Rasheed; J Todd; M Vahey; P Reichelderfer
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

5.  Variance of plasma human immunodeficiency virus type 1 RNA levels measured by branched DNA within and between days.

Authors:  S G Deeks; R L Coleman; R White; C Pachl; M Schambelan; D N Chernoff; M B Feinberg
Journal:  J Infect Dis       Date:  1997-08       Impact factor: 5.226

6.  Intra-assay performance characteristics of five assays for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  H J Lin; L Pedneault; F B Hollinger
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

7.  An enhanced-sensitivity branched-DNA assay for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  D Kern; M Collins; T Fultz; J Detmer; S Hamren; J J Peterkin; P Sheridan; M Urdea; R White; T Yeghiazarian; J Todd
Journal:  J Clin Microbiol       Date:  1996-12       Impact factor: 5.948

8.  Multicenter comparison of three commercial methods for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  R Schuurman; D Descamps; G J Weverling; S Kaye; J Tijnagel; I Williams; R van Leeuwen; R Tedder; C A Boucher; F Brun-Vezinet; C Loveday
Journal:  J Clin Microbiol       Date:  1996-12       Impact factor: 5.948

9.  Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS.

Authors:  W A O'Brien; P M Hartigan; D Martin; J Esinhart; A Hill; S Benoit; M Rubin; M S Simberkoff; J D Hamilton
Journal:  N Engl J Med       Date:  1996-02-15       Impact factor: 91.245

10.  Prognosis in HIV-1 infection predicted by the quantity of virus in plasma.

Authors:  J W Mellors; C R Rinaldo; P Gupta; R M White; J A Todd; L A Kingsley
Journal:  Science       Date:  1996-05-24       Impact factor: 47.728

  10 in total
  4 in total

1.  Quantification of proviral load of human immunodeficiency virus type 2 subtypes A and B using real-time PCR.

Authors:  F Damond; D Descamps; I Farfara; J N Telles; S Puyeo; P Campa; A Leprêtre; S Matheron; F Brun-Vezinet; F Simon
Journal:  J Clin Microbiol       Date:  2001-12       Impact factor: 5.948

2.  Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma.

Authors:  D G Murphy; L Côté; M Fauvel; P René; J Vincelette
Journal:  J Clin Microbiol       Date:  2000-11       Impact factor: 5.948

3.  Quantification of human immunodeficiency virus type 1 proviral load by a TaqMan real-time PCR assay.

Authors:  N Désiré; A Dehée; V Schneider; C Jacomet; C Goujon; P M Girard; W Rozenbaum; J C Nicolas
Journal:  J Clin Microbiol       Date:  2001-04       Impact factor: 5.948

4.  Viral Load Monitoring in HIV Infection.

Authors: 
Journal:  Curr Infect Dis Rep       Date:  1999-12       Impact factor: 3.663

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.