Literature DB >> 9974229

Effects of display resolution on visual performance.

M Ziefle1.   

Abstract

The role of display resolution in visual information processing was investigated in 2 experiments. Experiment 1 examined the effects of 2 CRT conditions (resolutions of 60 and 120 dots per inch [dpi]) and a paper control condition (255 dpi) on proofreading speed and accuracy. The results showed that reading performance was significantly better in the paper condition than in the 2 CRT conditions. Experiment 2 examined the effects of 3 different CRT resolutions (62, 69, and 89 dpi) on eye movement parameters (fixation duration and number of fixations) in a visual search task. Further, search reaction times (RTs) and observers' ratings of visual fatigue were analyzed. RTs and fixation durations were significantly increased in the low-resolution condition (62 dpi) as compared with the high-resolution condition (89 dpi). The significant interaction between display resolution and time both for search RTs and fixation durations was taken as evidence for stronger fatigue in the low-resolution conditions. Additionally, the extent of visual fatigue correlates both with search RTs and eye movement parameters. This finding gives rise to the assumption that observers' responsiveness to effects of display resolution in terms of visual fatigue differs markedly. Actual or potential applications of this research include recommendations for the use of high-resolution displays (90 dpi and greater) to optimize visual performance, to make prolonged on-screen viewing more comfortable, and to avoid visual fatigue.

Entities:  

Mesh:

Year:  1998        PMID: 9974229     DOI: 10.1518/001872098779649355

Source DB:  PubMed          Journal:  Hum Factors        ISSN: 0018-7208            Impact factor:   2.888


  9 in total

1.  Real-time occupational stress and fatigue measurement in medical imaging practice.

Authors:  Elizabeth Krupinski; Bruce I Reiner
Journal:  J Digit Imaging       Date:  2012-06       Impact factor: 4.056

2.  Psychological factors and visual fatigue in working with video display terminals.

Authors:  F Mocci; A Serra; G A Corrias
Journal:  Occup Environ Med       Date:  2001-04       Impact factor: 4.402

3.  The HD-Panoramic Visualization System: a new visualization system for ENT surgery.

Authors:  G Strauss; N Bahrami; M Hofer; E Dittrich; M Strauss; A Dietz
Journal:  Eur Arch Otorhinolaryngol       Date:  2008-12-20       Impact factor: 2.503

Review 4.  [A new visualization device for ENT surgery : the panoramic visualization system (HD-PVS)].

Authors:  G Strauss; M Hofer; N Bahrami; E Dittrich; M Strauss; A Dietz
Journal:  HNO       Date:  2009-05       Impact factor: 1.284

Review 5.  Computer and visual display terminals (VDT) vision syndrome (CVDTS).

Authors:  J K S Parihar; Vaibhav Kumar Jain; Piyush Chaturvedi; Jaya Kaushik; Gunjan Jain; Ashwini K S Parihar
Journal:  Med J Armed Forces India       Date:  2016-05-25

6.  Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects.

Authors:  Jun Ho Kim; Reinaldo Abdala-Júnior; Luciana Munhoz; Arthur Rodriguez Gonzalez Cortes; Plauto Christopher Aranha Watanabe; Claudio Costa; Emiko Saito Arita
Journal:  Imaging Sci Dent       Date:  2020-06-18

7.  Comparing Traditional and Digitized Cognitive Tests Used in Standard Clinical Evaluation - A Study of the Digital Application Minnemera.

Authors:  Stina Björngrim; Wobbie van den Hurk; Moises Betancort; Alejandra Machado; Maria Lindau
Journal:  Front Psychol       Date:  2019-10-18

8.  Informing potential participants about research: observational study with an embedded randomized controlled trial.

Authors:  Helen M Kirkby; Melanie Calvert; Richard J McManus; Heather Draper
Journal:  PLoS One       Date:  2013-10-03       Impact factor: 3.240

9.  The effect of image resolution of display types on accommodative microfluctuations.

Authors:  Niall J Hynes; Matthew P Cufflin; Karen M Hampson; Edward Ah Mallen
Journal:  Ophthalmic Physiol Opt       Date:  2022-02-01       Impact factor: 3.992

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.