Literature DB >> 9973990

Screw home motion after total knee replacement.

Y Ishii1, K Terajima, Y Koga, J E Bechtold.   

Abstract

The objective of this study was to evaluate the effect of muscle force and the posterior cruciate ligament on screw home motion in patients with total knee replacement in a posterior cruciate ligament retaining prosthesis (10 knees) and a posterior cruciate ligament substituting prosthesis (10 knees). Screw home motion was examined with only active extension and with two types of externally loaded active extension (2 kg and body weight). Screw home motion was measured with a 6 degrees of freedom electrogoniometer (instrumented spatial linkage). Retaining the posterior cruciate ligament maintained screw home motion, with and without external load to muscles, whereas substituting the posterior cruciate ligament maintained screw home motion only under the full external load of body weight. This was not seen with a 2-kg external load. As for the normal knee, it appears that screw home motion of a prosthetic knee is influenced, not only by the presence of ligamentous structures, but also by the activity of the muscles. The activity of the muscles may have a much greater effect on screw home motion with currently used prosthetic designs than does the presence of ligamentous structures.

Entities:  

Mesh:

Year:  1999        PMID: 9973990

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

1.  Synchronisation of tibial rotational alignment with femoral component in total knee arthroplasty.

Authors:  Dong-Hoon Lee; Jai-Gon Seo; Young-Wan Moon
Journal:  Int Orthop       Date:  2007-01-12       Impact factor: 3.075

2.  Changes in knee kinematics reflect the articular geometry after arthroplasty.

Authors:  Anthony M J Bull; Oliver Kessler; Mahbub Alam; Andrew A Amis
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

3.  How to minimize rotational conflict between femoral & tibial component in total knee arthroplasty: the use of femoro-tibial axial synchronizer (Linker).

Authors:  Jai-Gon Seo; Young-Wan Moon; Sang-Min Kim; Sang-Hoon Park
Journal:  Yonsei Med J       Date:  2015-03       Impact factor: 2.759

4.  A generalized framework for determination of functional musculoskeletal joint coordinate systems.

Authors:  Tara F Nagle; Ahmet Erdemir; Robb W Colbrunn
Journal:  J Biomech       Date:  2021-08-03       Impact factor: 2.789

Review 5.  Three-dimensional motion analysis and its application in total knee arthroplasty: what we know, and what we should analyze.

Authors:  Yoshio Koga
Journal:  J Orthop Sci       Date:  2015-01-22       Impact factor: 1.601

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.